MISCELLANEOUS

The AIR series are unquestionably high quality products. This section focuses on a few technical issues that adds to the perception of the high standard of the products.

High efficiency compact Switched Mode Power Supply (SMPS)

For saving overhead power consumption and to insure optimal performance disregarding the mains voltage, the unit is equipped with a high efficiency compact Switched Mode Power Supply (SMPS). Using switched technology both in amplifiers and power supply can reduce the heat sink size to about 1/3 the size of what it would be with regular power supply and class AB amplifiers.

Power saving shut down modes

The amplifier can detect whether or not there is Input on the analog or digital line. If input is absent for more than half an hour all monitors in a network will go to sleep- mode. from which they can recover automatically when signal is received. The power up time from sleep is a few hundred ms.

If Input signal is absent for more than 2½ hours the system will go into standby from which it can recover by user intervention such as touching the volume wheel on the Remote Control or by touching the Master monitor display.

Software updates

Each monitor in a setup can be software updated via Network. This is done through PC/Mac using the AIR SOFT. Follow the Software update procedure as described on www.dynaudioacoustics.com

Reset Procedures

Three different levels of “Reset” exists. For all three scenarios all connected monitors will be affected.

The following Reset procedures are accessed by holding the ENTER key on the System Controller while powering up:

Clear Monitor Settings

All global and local parameters in connected monitors are reset. Preset and network settings are not affected.

Reset all Settings

A “factory” reset procedure that deletes all global and local parameter settings as well as preset and network settings.

The following reset procedure is found in the Setup menu:

Clear Setup for entire network

Select this reset procedure to clear all network settings.

Global Parameters

These parameters applies for the entire System:

Global parameters stored with presets

Bass Management

Mute Status

Global parameters NOT stored with presets

Ref. Levels

Analog Input Sensitivity

Selected Setup

BNC Sync

Local Parameters

These parameters applies for individual monitors:

Local parameters stored with presets

X-Curve

Parametric EQ setting (set via AIR PC-IP)

LFE Gain (subs)

LFE Low Pass (subs)

Rel. Level

Local parameters NOT stored with presets

Bass and Treble

Delay

Lock status (set via AIR PC-IP)

Room position

Calibration Level

Tasks

Phase (Subs)

Polarity (Subs)

51

Image 53
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup SetupsStereo Setup with mono Subs Stereo Setup with stereo SubsAnalog Setup Digital SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupOther Chained Setups Stereo Setup With Chains on L & RAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup This Manual IntroductionBreak Product ConceptCommon Features Remote ControlMaster Unit Slave & Sub UnitsMaster Unit Analog I/O Rear Panel Description MasterSlave/Sub Optional Digital I/O cardOverload Indication AIR DisplayEnter key Cursor UP/DOWN keys Overload Indication LEDParameter Description Press Enter to access the Select ModeBasic operation in all menus Main DisplaySetup Setup MenuSet Monitor Task External ClockStore LFE channel noteRecall Overview Placing the MonitorsOther situations Close to wall / WallOn the bridge / Console Phase checking Checking the placementChecking by ear when listening to the signals In phase EvaluationNext EqualizingInterchannel calibration Calibrating Main Monitors CurvesAcoustic level calibration CurvePlacing the Subwoofer Evaluation Low frequency sweepsTo Calibrate Checking summing phase cancellationControlling standing waves Checking the CrosspointPhase Introduction PhaseLFE Gain PolarityReverberation time AcousticsGood acoustics Sabines formula Diffusers AbsorbersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLFE Channel Subwoofer & LFE Channel Background InfoCross-overs Low Pass LFE GainCinema setup Delaying Monitors LINE-UP & CalibrationAcoustic summation of audio signals Calibration of 5.1 in an ITU-775 arrangement How to measure the sound pressure?LINE-UP & Calibration Background Info Introduction Remote Control FeaturesAIR Remote Volume potentiometer Preset 1/3 and 2/4 keysREF Level 1-3 keys Shift keyNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseMiscellaneous Reset ProceduresGlobal Parameters Local ParametersTC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2AIR Remote specs Room & DistanceGeneral for all Products Error messages etc Delay in System & Error Messages ETCAIR AIR-Base Certificate of ConformityCertificate Of Conformity # Name Preset List