Dynaudio Air Series manual Dig/6 Master, This illustration shows how to connect a 6.1 Analog setup

Page 12

SETUPS

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

Channels must be connected as follows:

-Left channel to Left Input on Left monitor.

-Right channel to Right Input on Left monitor.

-Center channel to Left Input on Center monitor.

-LFE channel to Right Input on Center monitor.

-Left Surround channel to Left Input on Left Surround monitor.

-Right Surround channel to Right Input on Left Surround monitor.

6.1 Analog Setup

This illustration shows how to connect a 6.1 Analog setup

Left is set as System Controller by leaving out the TC Link button on the rear panel.

Left monitor receives both the Left and Right signal. The Right monitor is fed via the TC LINK RJ-45 connection form Left to Right.

Center monitor receives both Center and LFE signal. The LFE monitor is fed via the TC LINK RJ-45 connection from Center to LFE.

Left Surround monitor receives both LS and RS signal. The RS monitor is fed via the TC LINK RJ-45 connection from LS to RS.

The Center Surround monitor receives only Center Surround signal.

Center Chain: From software 1.10 it is possible to connect one or more Center Chain monitors.

With Bass-management “off” only the LFE signal is fed to the Sub.

With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

To set a Master monitor as System Controller the TC Link button on the rear panel MUST be in out-position.

5.1 Dig/6 - Master

This is a 5.1 digital setup with Bass Management as an option. The setup requires one Master monitor with the optional Digital AES/EBU Input Card installed, four Slave monitors (or Masters set as Slave) and one Sub.

Center monitor is set as System Controller by leaving out the TC Link button on the rear panel.

Center monitor receives all 6 channels on the three AES/EBU connections.

-Center and LFE on the monitors Digital IN connection.

-Left and Right on the I/O cards Digital IN no. 2.

-LS and RS on the I/O cards Digital IN no. 3.

Right, Left, Sub, LS and RS receives signal via TC LINK RJ-45 connections from the Center Master monitor.

Clock MUST be sent on the AES connection feeding Center/LFE channels (or on BNC).

With Bass-management “off” only the LFE signal is fed to the Sub.

With Bass-management activated, Low Frequency information below the set Cross-over frequency from the 5 main channels is extracted and distributed to the Sub where it is summed with the LFE channel.

The Remote, AIR Soft and AIR PC-IP can be connected to any available TC LINK Out connection.

10

Image 12
Contents Page Page Important Safety Instructions Voltage Line plug according to standardPage Table of Contents Quick Setup Reference Quick Setup Reference Operational Overview Main DisplaySetups Stereo SetupStereo Setup with mono Subs Stereo Setup with stereo SubsDigital Setup Analog SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterStereo Setup With Chains on L & R Other Chained SetupsAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup Introduction This ManualBreak Product ConceptRemote Control Common FeaturesMaster Unit Slave & Sub UnitsRear Panel Description Master Master Unit Analog I/OSlave/Sub Optional Digital I/O cardAIR Display Overload IndicationEnter key Cursor UP/DOWN keys Overload Indication LEDPress Enter to access the Select Mode Parameter DescriptionBasic operation in all menus Main DisplaySetup Menu SetupSet Monitor Task External ClockLFE channel note RecallStore Placing the Monitors OverviewClose to wall / Wall On the bridge / ConsoleOther situations Checking the placement Phase checkingChecking by ear when listening to the signals In phase EvaluationEqualizing NextCalibrating Main Monitors Curves Interchannel calibrationAcoustic level calibration CurvePlacing the Subwoofer Low frequency sweeps EvaluationChecking summing phase cancellation To CalibrateControlling standing waves Checking the CrosspointPhase Phase IntroductionLFE Gain PolarityAcoustics Good acousticsReverberation time Sabines formula Absorbers DiffusersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferSubwoofer & LFE Channel Background Info LFE ChannelCross-overs Low Pass LFE GainDelaying Monitors LINE-UP & Calibration Acoustic summation of audio signalsCinema setup How to measure the sound pressure? LINE-UP & Calibration Background InfoCalibration of 5.1 in an ITU-775 arrangement Remote Control Features AIR RemoteIntroduction Preset 1/3 and 2/4 keys Volume potentiometerREF Level 1-3 keys Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR-Base Chained monitorsReset Procedures MiscellaneousGlobal Parameters Local ParametersCables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveAIR-Base-1 & AIR-Base-2 AIR BaseRoom & Distance General for all ProductsAIR Remote specs Delay in System & Error Messages ETC Error messages etcCertificate of Conformity Certificate Of ConformityAIR AIR-Base Preset List # Name