Dynaudio Air Series manual Preset List, # Name

Page 60

58

#Name

1-15

"## Empty"/"

 

 

 

 

 

 

 

Preset one to fifteen are "empty" until you choose to store something after which it says "User Preset"

 

 

 

 

 

 

 

## User Preset"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preset Level (dB)

 

 

Bass M.

X-curve 1

X.Curve #2

 

Factory Presets

Typical Applications

L

C

R

Ls

Rs

SUB

LFE

X-over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

Neutral

All parameters neutral - a good starting point

0

0

0

0

0

0

0dB gain

Off

Off

Off

17

BassMgr ??Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

50Hz

Off

Off

18

BassMgr 80Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

80Hz

Off

Off

19

BassMgr 95Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

95Hz

Off

Off

20

BassMgr 110Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

110Hz

Off

Off

21

BassMgr 115Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

115Hz

Off

Off

22

BassMgr 120Hz

Music, video and post for domestic (Not Cinema) use - Stereo, 5.1, 5.3 and 6.1

0

0

0

0

0

0

0dB gain

120Hz

Off

Off

23

Cinema Flat

Mixing for Cinema without compensation for X-curve. 5.1

0

0

0

-3

-3

0

0dB gain

Off

Off

Off

24

Cine X-curve

Mixing for Cinema in a small room - compensates for X-curve. 5.1

0

0

0

-3

-3

0

0dB gain

Off

Yes

Off

25

Cine X-curve2

Mixing for Cinema in a small room - compensates for modified X-curve. 5.1

0

0

0

-3

-3

0

0dB gain

Off

Off

Yes

26

Cinema X+50Hz

Mixing for Cinema with small room X-curve compensation and bass Management.

0

0

0

-3

-3

0

0dB gain

80Hz

Yes

Off

27

Cinema X+80Hz

Mixing for Cinema with small room X-curve compensation and bass Management

0

0

0

-3

-3

0

0dB gain

80Hz

Yes

Off

28

CinemX+120Hz

Mixing for Cinema with small room X-curve compensation and bass Management

0

0

0

-3

-3

0

0dB gain

120Hz

Yes

Off

29

Cinema 80Hz

Mixing for Cinema with Bass management but without compensation for X-curve

0

0

0

-3

-3

0

0dB gain

80Hz

Off

Off

30

Cinema 120Hz

Mixing for Cinema with Bass management but without compensation for X-curve

0

0

0

-3

-3

0

0dB gain

120Hz

Off

Off

31

OB Van 120Hz

OB vans and very small rooms where rear-channels are close to sweetspot

0

0

0

-2

-2

0

0dB gain

120Hz

Off

Off

32

Neutral

All parameters neutral - a good starting point

0

0

0

0

0

0

0dB gain

Off

Off

Off

 

X-curve #1

ANSI / SMPTE222M (1.5dB roll off per oct. from 2kHz)) Please refer to page 25

 

 

 

 

 

 

 

 

 

 

 

X-curve #2

ANSI / SMPTE222M Mod. (3dB roll off per oct. from 4kHz) Please refer to page 25

 

 

 

 

 

 

 

 

 

 

 

LFE Gain

Please note that the LFE channel should be mixed with +10dB headroom.

 

 

 

 

 

 

 

 

 

 

 

 

If you are not able to boost your LFE monitor output, you should add +10dB gain on

 

 

 

 

 

 

 

 

 

 

your AIR-Base.

Most format encoders / decoders take the LFE boost into account, meaning that you should leave the AIR-Base LFE gain at 0dB

when playing back a DTS or DOLBY encoded material on your AIR system

PRESET LIST

Image 60
Contents Page Page Important Safety Instructions Voltage Line plug according to standardPage Table of Contents Quick Setup Reference Quick Setup Reference Operational Overview Main DisplaySetups Stereo SetupStereo Setup with mono Subs Stereo Setup with stereo SubsDigital Setup Analog SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Digital setup This illustration shows how to connect a 5.3 Analog setupThis illustration shows how to connect a 6.1 Analog setup Dig/6 MasterStereo Setup With Chains on L & R Other Chained SetupsAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup Introduction This ManualBreak Product ConceptRemote Control Common FeaturesMaster Unit Slave & Sub UnitsRear Panel Description Master Master Unit Analog I/OSlave/Sub Optional Digital I/O cardAIR Display Overload IndicationEnter key Cursor UP/DOWN keys Overload Indication LEDPress Enter to access the Select Mode Parameter DescriptionBasic operation in all menus Main DisplaySetup Menu SetupSet Monitor Task External ClockLFE channel note RecallStore Placing the Monitors OverviewClose to wall / Wall On the bridge / ConsoleOther situations Checking the placement Phase checkingChecking by ear when listening to the signals In phase EvaluationEqualizing NextCalibrating Main Monitors Curves Interchannel calibrationAcoustic level calibration CurvePlacing the Subwoofer Low frequency sweeps EvaluationChecking summing phase cancellation To CalibrateControlling standing waves Checking the CrosspointPhase Phase IntroductionLFE Gain PolarityAcoustics Good acousticsReverberation time Sabines formula Absorbers DiffusersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersBackground Info Acoustics Standing WavesRoom modes Axial Tangential RadialHow to prohibit standing waves How does the standing waves influence the sound field?Acoustics Background Info Comb Filtering Or + Dip frequenciesRear wall cancellation Subwoofer Background Info SubwooferSubwoofer & LFE Channel Background Info LFE ChannelCross-overs Low Pass LFE GainDelaying Monitors LINE-UP & Calibration Acoustic summation of audio signalsCinema setup How to measure the sound pressure? LINE-UP & Calibration Background InfoCalibration of 5.1 in an ITU-775 arrangement Remote Control Features AIR RemoteIntroduction Preset 1/3 and 2/4 keys Volume potentiometerREF Level 1-3 keys Shift keyAIR Soft Navigating AIR SoftMain ToolsPreset List NetworkSystem Setup Calibrate AIR-Base Chained monitorsReset Procedures MiscellaneousGlobal Parameters Local ParametersCables TC Link Standard Cat-5 cablesAES/EBU Standard cables Serial to Cat-5 cableAIR 6 & AIR 15 Master and Slave AIR 20 & AIR 25 Master and SlaveAIR-Base-1 & AIR-Base-2 AIR BaseRoom & Distance General for all ProductsAIR Remote specs Delay in System & Error Messages ETC Error messages etcCertificate of Conformity Certificate Of ConformityAIR AIR-Base Preset List # Name