Dynaudio Air Series REF Level 1-3 keys, Preset 1/3 and 2/4 keys, Shift key, Volume potentiometer

Page 47

THE AIR REMOTE

REF LEVEL 1-3 keys

To recall Reference Level 1-3:

Press relevant key shortly. The key LED indicates activated Reference Level.

To set Reference Level 1-3:

Set level using the large VOLUME dialer in the center of the remote. Press and hold relevant Reference level key for approx. 2 seconds. The LED will flash 3 times and then the new Reference level is set.

Power up state: Off (volume defined by potentiometer)

PRESET 1/3 AND 2/4 keys

These keys will recall presets 1/3 & 2/4 depending on the position of the SHIFT key.

Power up state: Off (no presets recalled).

SHIFT key

Combined with the PRESET 1/3 AND 2/4 keys (described above) presets 1 to 4 can be recalled.

Preset Bank 1 is presets 1and 2. Preset bank 2 is presets 3 and 4.

Power up state: Preset Bank 1 selected.

MUTE/UNMUTE - SOLO keys for the channels: L - C - R - Ls - SUB - Rs

The key LEDs indicates the following states:

LED ON

Speaker on

LED OFF

Speaker Mute

LED Flashing

Speaker Solo

Mute/Unmute

With a single press on these keys the monitors are muted/unmuted.

Solo Function

Press and hold one of the keys to activate Solo function for corresponding channel.

All other monitors can enter solo mode simultaneously. If a key is pressed (not held) the original mute status will be recalled.

Power up state: On

VOLUME potentiometer

If no REFERENCE LEVEL keys are activated this control sets the Master volume on all channels in the system.

If one of the REFERENCE LEVEL keys are activated, these will define the reference level.

When REFERENCE LEVEL keys are deactivated Master volume returns to the level defined by the position of the VOLUME potentiometer.

Power up state: Potentiometer setting defines volume level.

Potentiometer LED function:

As soon as the volume level is defined by the potentiometer setting, the LED is on. LED goes off when volume is set by other devices than the remote unit.

Power up state: LED on (Potentiometer setting defines volume level).

45

Image 47
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup with stereo Subs SetupsStereo Setup Stereo Setup with mono SubsThis illustration shows how to connect a 5.1 analog setup Digital SetupAnalog Setup This illustration shows how to connect a 5.1 digital setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupAnalog connections Stereo Setup With Chains on L & ROther Chained Setups Analog/Digital setupDigital 192 kHz Digital Setup Product Concept IntroductionThis Manual BreakSlave & Sub Units Remote ControlCommon Features Master UnitOptional Digital I/O card Rear Panel Description MasterMaster Unit Analog I/O Slave/SubOverload Indication LED AIR DisplayOverload Indication Enter key Cursor UP/DOWN keysMain Display Press Enter to access the Select ModeParameter Description Basic operation in all menusExternal Clock Setup MenuSetup Set Monitor TaskStore LFE channel noteRecall Overview Placing the MonitorsOther situations Close to wall / WallOn the bridge / Console Evaluation Checking the placementPhase checking Checking by ear when listening to the signals In phaseNext EqualizingCurve Calibrating Main Monitors CurvesInterchannel calibration Acoustic level calibrationPlacing the Subwoofer Evaluation Low frequency sweepsChecking the Crosspoint Checking summing phase cancellationTo Calibrate Controlling standing wavesPolarity PhasePhase Introduction LFE GainReverberation time AcousticsGood acoustics Sabines formula Absorbtion or diffusion ? Resonance absorbers AbsorbersDiffusers Membrane absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLow Pass LFE Gain Subwoofer & LFE Channel Background InfoLFE Channel Cross-overs Cinema setup Delaying Monitors LINE-UP & Calibration Acoustic summation of audio signals Calibration of 5.1 in an ITU-775 arrangement How to measure the sound pressure?LINE-UP & Calibration Background Info Introduction Remote Control FeaturesAIR Remote Shift key Preset 1/3 and 2/4 keysVolume potentiometer REF Level 1-3 keysNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseLocal Parameters Reset ProceduresMiscellaneous Global ParametersSerial to Cat-5 cable CablesTC Link Standard Cat-5 cables AES/EBU Standard cablesAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2AIR Remote specs Room & DistanceGeneral for all Products Error messages etc Delay in System & Error Messages ETCAIR AIR-Base Certificate of ConformityCertificate Of Conformity # Name Preset List