AIR TECHNICAL SPECIFICATIONS

Room & Distance

Typical listening distance

 

 

 

AIR 6

AIR 15

AIR 20

AIR 25

1.2-2 m / 4-7 ft

1.5-2.5 m / 5-8,5 ft

1.5-3 m / 5-10.2 ft

 

Typical room size

 

 

 

AIR 6

AIR 15

AIR 20

AIR 25

50-100 m3 / 1600-3500 ft

75-125 m3 /2600-4400 ft

80-130 m3 / 2800-4600 ft3

 

AIR-Base-1

AIR-Base-2

Two or three AIR-Base-1’s

Two or three AIR-Base-1’s

30-60 m3 / 1000-2000 ft3

50-100 m3 / 1600-4400 ft3

50-100 m3 / 1600-3500 ft3

75-125 m3 / 2600-4400 ft3

 

 

 

 

General specifications for AIR 6, AIR 15, AIR 20, AIR 25, AIR-Base-1, AIR-Base-2, AIR-Base 12 & AIR Base 24

System sample rates

 

Internal sample rate

192 and 176.4 via Dual Wire (optional Digital Card required) and

 

96, 88.2, 64, 48, 44.1 or 32 kHz

 

 

AIR Masters only

 

I/O Connectors

XLR (2 channels AES/EBU in) 3 x RJ45 proprietary TC LINK

Formats

AES/EBU (24 bit)

Word clock input

BNC, 75 ohm, 0.6 to 10 Vpp

Display

2 x 16 character dot matrix

Operation

Menu system / four buttons

 

 

Analog input option

 

Input connectors

XLR balanced (pin 2+, pin 3-)

Impedance

10/3 k Ohm (Balanced/unbalanced)

Selectable full scale input level

+9, +15, +21, +27 dBu

Dynamic Range

> 113 dB typ. (unweighted), BW: 20-20kHz

THD+N

< -105 dB typ. @ 1 kHz, -3 dBFS

Crosstalk

< -120 dB, 20 Hz to 20 kHz

A to D Conversion

24 bit (Dual bit delta sigma sampling at 4.1/5.6/6.1/6.1 MHz)

 

 

AIR Slaves only

 

I/O Connectors

2 x RJ45 proprietary TC LINK

General for all Products

EMC complies with:

EN 55103-1 and EN 55103-2, FCC part 15 class B, CISPR 22 class B

Safety certified to:

IEC 60065, EN 60065, UL 6500 and CSA E60065 CSA FILE

 

#LR108093

Environment operating Temperature:

32° F to 122° F (0° C to 50° C)

Storage Temperature:

-22° F to 167° F (-30° C to 70° C)

Humidity:

Max. 90 % non-condensing

Warranty

2 years on parts and labor

AIR Remote specs

AIR Remote

 

Finish:

Black anodized aluminum and plastic

 

 

Dimensions (D x W x H):

120 x 70 x 35 mm

Weight:

250g

I/O Connectors:

1 x RJ45 proprietary TC LINK

 

 

EMC

 

Complies with:

EN 55103-1 and EN 55103-2,

 

FCC part 15 class B, CISPR 22 class B

 

 

Safety

 

Certified to:

IEC 60065, EN 60065, UL 6500 and CSA E60065

 

CSA FILE #LR108093

 

 

Environment

 

Operating Temperature:

32° F to 122° F (0° C to 50° C)

Storage Temperature:

-22° F to 167° F (-30° C to 70° C)

Humidity:

Max. 90 % non-condensing

 

 

Warranty

 

Parts and labor:

1 year on parts and labor

55

Image 57
Contents Page Page Voltage Line plug according to standard Important Safety InstructionsPage Table of Contents Quick Setup Reference Quick Setup Reference Main Display Operational OverviewStereo Setup SetupsStereo Setup with mono Subs Stereo Setup with stereo SubsAnalog Setup Digital SetupThis illustration shows how to connect a 5.1 digital setup This illustration shows how to connect a 5.1 analog setupThis illustration shows how to connect a 5.3 Analog setup This illustration shows how to connect a 5.3 Digital setupDig/6 Master This illustration shows how to connect a 6.1 Analog setupOther Chained Setups Stereo Setup With Chains on L & RAnalog/Digital setup Analog connectionsDigital 192 kHz Digital Setup This Manual IntroductionBreak Product ConceptCommon Features Remote ControlMaster Unit Slave & Sub UnitsMaster Unit Analog I/O Rear Panel Description MasterSlave/Sub Optional Digital I/O cardOverload Indication AIR DisplayEnter key Cursor UP/DOWN keys Overload Indication LEDParameter Description Press Enter to access the Select ModeBasic operation in all menus Main DisplaySetup Setup MenuSet Monitor Task External ClockLFE channel note RecallStore Overview Placing the MonitorsClose to wall / Wall On the bridge / ConsoleOther situations Phase checking Checking the placementChecking by ear when listening to the signals In phase EvaluationNext EqualizingInterchannel calibration Calibrating Main Monitors CurvesAcoustic level calibration CurvePlacing the Subwoofer Evaluation Low frequency sweepsTo Calibrate Checking summing phase cancellationControlling standing waves Checking the CrosspointPhase Introduction PhaseLFE Gain PolarityAcoustics Good acousticsReverberation time Sabines formula Diffusers AbsorbersMembrane absorbers Absorbtion or diffusion ? Resonance absorbersStanding Waves Background Info AcousticsAxial Tangential Radial Room modesHow does the standing waves influence the sound field? How to prohibit standing wavesAcoustics Background Info Comb Filtering Dip frequencies Or +Rear wall cancellation Subwoofer Subwoofer Background InfoLFE Channel Subwoofer & LFE Channel Background InfoCross-overs Low Pass LFE GainDelaying Monitors LINE-UP & Calibration Acoustic summation of audio signalsCinema setup How to measure the sound pressure? LINE-UP & Calibration Background InfoCalibration of 5.1 in an ITU-775 arrangement Remote Control Features AIR RemoteIntroduction Volume potentiometer Preset 1/3 and 2/4 keysREF Level 1-3 keys Shift keyNavigating AIR Soft AIR SoftTools MainNetwork Preset ListSystem Setup Chained monitors Calibrate AIR-BaseMiscellaneous Reset ProceduresGlobal Parameters Local ParametersTC Link Standard Cat-5 cables CablesAES/EBU Standard cables Serial to Cat-5 cableAIR 20 & AIR 25 Master and Slave AIR 6 & AIR 15 Master and SlaveAIR Base AIR-Base-1 & AIR-Base-2Room & Distance General for all ProductsAIR Remote specs Error messages etc Delay in System & Error Messages ETCCertificate of Conformity Certificate Of ConformityAIR AIR-Base # Name Preset List