Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
B-34 OPERATION
EXAMPLE 1 - 2 STEP TRIGGER: Simple operation The simplest trigger operation occurs with a 2 Step trigger and the Start, Crater and Burnback functions all set to OFF. (See Figure B.19)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the gun trigger is pulled.
STRIKE:
After preflow time expires, the power source regulates to the welding output and wire is advanced towards the work piece at the strike
WELD:
The power source output and the wire feed speed con- tinue at the weld settings for as long as the trigger is pulled.
POSTFLOW: As soon as the trigger is released, the power source output and the wire feed speed are turned OFF. Shielding gas continues until the post flow timer expires.
to Section TOC
to Master TOC
Idle
Shielding On
Trigger Pulled | Arc Established |
Preflow | Strike |
FIGURE B.19
2 Step Trigger
Start = OFF
Crater = OFF
Burnback = OFF
Weld
Trigger Released
Pos tflow | Idle |
Return
Return
Gas
Off
Power | Weld | |
1.5 sec max. | ||
Source | ||
Output | Off | |
|
Return to Section TOC
Return to Master TOC
WFS
Weld
Off