Lincoln Electric Pro-MIG 140 Changing Machine Over to Feed Other Wire Sizes, Overload Protection

Page 18

B-6

OPERATION

B-6

 

 

 

The Pro-MIG 140 is suitable for .035" aluminum wire and .030" stainless wire. Refer to Table B.1 for recom- mended procedure settings.

TABLE B.1

 

 

Shielding

 

Voltage/Wire Speed

 

 

 

Process

Welding Wire

Gas

22 ga

16 ga

12 ga

1/8”

3/16”

1/4”

 

 

 

 

 

 

 

 

 

 

.035 Dia(0.9mm

100% Argon

A-4.5

C-8.5

D-10

NR

NR

NR

 

4043 Aluminum

 

 

 

 

 

 

 

 

Wire

 

 

 

 

 

 

 

MIG DC+

 

 

18 ga

16 ga

14 ga

12 ga

10ga

 

 

 

 

 

 

 

 

 

 

.030 Dia

98% Argon/

B-6

C-6.5

D-7.5

NR

NR

 

 

308L Stainless

2% Oxygen

 

 

 

 

 

 

 

Steel Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

NR - Not Recommended

CHANGING MACHINE OVER TO FEED OTHER WIRE SIZES

The Pro-MIG 140 is shipped from the factory ready to feed .035” (0.9 mm) diameter wire. To operate the Pro-MIG 140 with other sizes of wire, it is necessary to change the appropriate contact tip, diffuser, nozzle and change the drive roll over to other sizes. Refer to Changing the Contact Tip and Changing the Drive Roll, in the MAINTENANCE section, for specific infor- mation on these procedures.

WELDING WITH GMAW (MIG)

Shielding Gas

When using the GMAW process, the correct drive roll and electrode polarity must be used. See Work Cable Installation in INSTALLATION section for changing the polarity.

When using the GMAW process, obtain and install a gas regulator and hose kit. If using CO2 a CO2 adapter is required, sold separately.

1.For CO2, open the cylinder very slowly. For argon- mixed gas, open cylinder valve slowly a fraction of a turn. When the cylinder pressure gauge pointer stops moving, open the valve fully.

2.If using a regulator with an adjustable flow meter, close the gun trigger and adjust the flow to give 15

20 cubic ft per hour (CFH) (7 – 10 I/min.) [use 20

25 CFH (10 – 12 I/min.) when welding out of

position or in a drafty location for CO2]. For argon mixed gas, trigger to release gas pressure, and adjust the flow to give 25 – 30 CFH (12 – 14 I/min.).

3.Keep the cylinder valve closed, except when using the Pro-MIG 140. When finished welding:

a) Close the cylinder valve to stop gas flow.

b) Depress the gun trigger briefly to release the pressure in the gas hose.

c) Turn off the Pro-MIG 140.

WELDING WITH FCAW (Innershield)

When using the FCAW process, the correct drive roll and electrode polarity must be used. See Work Cable Installation in INSTALLATION section for changing the polarity.

OVERLOAD PROTECTION

Output Overload

The Pro-MIG 140 is equipped with a circuit breaker and a thermostat which protects the machine from damage if maximum output is exceeded. The circuit breaker button will extend out when tripped. The cir- cuit breaker must be manually reset.

Thermal Protection

The Pro-MIG 140 has a rated output duty cycle of 20%. If the duty cycle is exceeded, a thermal protector will shut off the output until the machine cools to a reasonable operating temperature. This is an auto- matic function of the Pro-MIG 140 and does not require user intervention. The fan continues to run during cooling.

Electronic Wire Drive Motor Protection

The Pro-MIG 140 has built-in protection for wire drive motor overload.

Pro-MIG 140

Image 18
Contents Pro-MIG ARC Rays can burn SafetyFor Electrically powered equipment Electric and MagneticWelding Sparks can cause fire or explosion Electric Shock can killFumes and Gases can be dangerous Cylinder may explode if damagedIii Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents for ALL Sections Installation Electric Shock can kill Safety PrecautionsIdentify and Locate Components If you have not already done so, unpack the Pro-MIGOutput Connections Work Clamp InstallationSelect Suitable Location StackingConnecting Gun Cable to the Pro-MIG GUN InstallationWork Cable Installation GAS ConnectionFigure A.5 Input Connections Code Requirements for Input ConnectionsRequirements For Rated Output General Description Design FeaturesOperation Recommended ProcessesControls and Settings Welding CapabilityLimitations Wire Loading Welding OperationsSequence of Operation Friction Brake Adjustment Wire ThreadingCleaning Tip And Nozzle Process GuidelinesMaking a Weld Changing Machine Over to Feed Other Wire Sizes Welding with Gmaw MIGOverload Protection Application Chart Accessories Optional AccessoriesK586-1 Deluxe Adjustable Gas Regulator Hose Kit Replacement Parts Innershield Fcaw ConversionMaintenance Maintenance Safety PrecautionsRoutine Maintenance For Magnum 100L GUN GUN and Cable MaintenanceGun Cable Cleaning Contact Tips, Nozzles, and Gun TubesComponent Replacement Procedures Changing the Contact TIPChanging Drive Roll Changing Liner GUN Handle PartsLiner trim length Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Symptoms Cause Output ProblemsRecommended Course of Action GAS Flow Problems Problems SymptomsFeeding Problems Possible CauseAuthorized Field Service Contact your local LincolnFacility Wiring Diagram DiagramsPara equipos Electricos SeguridadAdvertencia LOS Campos Electricos Y MagneticosEl Electrochoque puede causar la muerte La Botella de gas puede explotar si está dañada Los Humos Y Gases pueden ser peligrososRegistro En línea Del Producto PrecauciónProducto Contenido Para Todas LAS Secciones Salida Nominal Dimensiones FísicasInstalación SalidaLea todo el manual antes de iniciar la instalación Precauciones DE SeguridadIdentifique Y Ubique LOS COM- Ponentes LA Descarga Eléctrica puede causar la muerteInclinacion Seleccion DEL Lugar AdecuadoEstibacion Instalacion DE LA Pinza DE TrabajoInstalacion DE LA Antorcha Conexión del Cable de la Antorcha a laPro-MIG Conexión DE GASFigura A.5 Conexiones DE LA Energía DE Alimentación Requerimientos de capacidad de salida nominalRequerimientos DEL Codigo Para Conexiones DE Entrada Descripción General OperaciónPrecauciones DE Seguridad Procesos RecomendadosCapacidad DE Soldadura LimitacionesControles Y Programaciones Secuencia DE Operación DE Soldadura Colocación DEL AlambreAjuste DEL Freno DE Fricción Colocacion DEL AlambreCómo Realizar UNA Soldadura Figura B.7Sobrecarga de Salida Soldadura CON Gmaw MIGGas Protector Protección térmicaAjustes Sugeridos Para LA Soldadura Accesorios Accesorios OpcionalesConversión DE Innershield Fcaw Partes DE ReemplazoMantenimiento Mantenimiento DE RutinaMantenimiento DE LA Antorcha Y EL Cable Limpieza del Cable de la AntorchaPuntas de Contacto, Toberas y Tubos de Antorcha Procedimeintos Para EL REEM- Plazo DE Componentes Cambiando LA Punta DE ContactoRodillo Impulsor QUE Cambia Cambio DE LA Guía DE Alambre Partes DE Manejo DE AntorchaLocalización DE Averías Cómo Utilizar a Guía DE Localización DE AveríasProblemas Posible Síntomas Causa Recomendado Línea DE ConductaTo con su facilidad autorizada Problemas DE AlimentaciónGAS Lincoln local del servicio deProblemas DE LA Soldadura Digrama Eléctrico Notas PRO-MIG PRO-MIG PRO-MIG Precaucion Warnung