Black & Decker 641915-00 Operation, Auto/On/Off Switch Set switch, Pressure Switch not shown

Page 11

641915-00,FSCP200 Compressor

3/14/06 7:31 AM Page 11

OPERATION

Know Your Air Compressor

READ THIS INSTRUCTION MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Description of Operation

Become familiar with these controls before operating the unit.

Auto/On/Off Switch: Set switch in

 

 

AUTO/ON position to provide automatic

Tank

Outlet

power to the pressure switch and OFF

Pressure

Pressure

to remove power at the end of each

Gauge

Gauge

 

use.

Auto/On/Off

 

Pressure Switch (not shown): The

 

Switch

 

pressure switch automatically starts the

 

 

 

motor when the air tank pressure drops

 

Regulator

below the factory set "cut-in" pressure.

 

 

It stops the motor when the air tank

 

 

pressure reaches the factory set "cut-

Safety

 

out" pressure.

 

Safety Valve: If the pressure switch

Valve

 

 

 

does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Drain Valve

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve (not shown): When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Motor Overload Protector (not shown): The motor has an automatic reset thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. The compressor will automatically restart after the motor cools.

The motor will automatically restart without warning if plugged in electrical outlet and "Auto/On/Off" switch is in the

"AUTO/ON" position.

11

Image 11
Contents VEA EL Español EN LA Contraportada Oil-Free Air CompressorSafety Guidelines / Definitions Hazard Important Safety InstructionsRisk of Bursting Risk of Electrical Shock Risk of Burns Risk of Unsafe Operation Model No SpecificationsInstallation HOW to SET UP Your Unit GlossaryGrounding Instructions Extension Cords Operation Auto/On/Off Switch Set switchPressure Switch not shown How to Use Your Unit To Check Safety Valve MaintenanceStorage Problem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Accessories Directives DE Sécurité Importantes Ne faites pas fonctionner l’appareil à Directives DE Sécurité ImportantesConservez CES Directives Dans un endroit propre, sec et bien aéréDe fixer des outils ou des accessoires ’air, vous devez installer un régulateurCommande pneumatique, des pneus et Compresseur. Suivez la recommandationDirectives de sécurité fournies sur Risque DE Chute Risque DE BrûluresPièces Mobiles Risque D’UTILISATION GlossaireDirectives DE Mise À LA Terre Installation Configuration DE Votre AppareilEmplacement du compresseur d’air SpécificationsDescription du fonctionnement FonctionnementProtection de la tension et du circuit Apprenez à connaître votre compresseur d’airComment l’arrêter Soupape de sûreté Si leManomètre de prise de courant Le Avant chaque fonctionnement Responsabilités du consommateur EntretienRangement Ne serrez pas trop. Si les fuites DépannageProblème Cause Correctif Risque de s’affaiblir. Le Ne percez pas, ne soudez pasOu ne modifiez pas le Réservoir d’air sans quoi ilTemporisation Garantie Complète DE Deux ANS Pour Usage Résidentiel AccessoiresInformation SUR LES Réparations 555326-7100 Conserve Estas Instrucciones Intrucciones DE Seguridad ImportantesDel tanque de acero Riesgo de estallidoCondensada del tanque, que Provoca óxido y adelgazamientoAl que se conecta el compresor suministre Riesgo DE Caídas Riesgo DE QuemadurasRiesgo POR Piezas Móviles Riesgo DE Operación Insegura GlosarioUbicación del compresor de aire EspecificacionesInstalación Como Ubicar SU Unidad Modelo NºConozca su compresor de aire FuncionamientoCables prolongadores Voltaje y protección del circuitoComo detenerla Cómo usar su unidadResponsabilidades del cliente MantenimientoAntes de cada arranque Almacenamiento No perfore Detección DE ProblemasProblema Causa Corrección No ajuste demasiado. Si lasMinutos para que el Otros Comuníquese con un centro de Servicio de B&D AccesoriosInformación DE Servicio Garantía Completa DE DOS Años Para USO EN EL HogarMEXICO, D.F CULIACAN, SIN MONTERREY, N.LGUADALAJARA, JAL PUEBLA, PUE641915-00,FSCP200 Compressor 641915-00,FSCP200 Compressor 641915-00,FSCP200 Compressor