Risk of Electrical Shock

WHAT CAN HAPPEN

Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock.

Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.

Electrical Grounding: Failure to provide adequate grounding to this product could result in serious injury or death from electrocution.

See grounding instructions.

HOW TO PREVENT IT

Never operate the compressor outdoors when it is raining or in wet conditions.

Never operate compressor with protective covers removed or damaged.

Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local electrical codes.

Make certain that the electrical circuit to which the compressor is connected provides proper electrical grounding, correct voltage and adequate fuse protection.

HAZARD

Risk to Breathing

WHAT CAN HAPPEN

The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon monoxide, toxic vapors, or solid particles from the tank. Breathing these contaminants can cause serious injury or death.

Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors and poisons.

HOW TO PREVENT IT

Air obtained directly from the compressor should never be used to supply air for human consumption. In order to use air produced by this compressor for breathing, suitable filters and in-linesafety equipment must be properly installed. In-linefilters and safety equipment used in conjunction with the compressor must be capable of treating air to all applicable local and federal codes prior to human consumption.

Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Use a NIOSH/ MSHA approved respirator designed for use with your specific application.

5

Image 5
Contents VEA EL Español EN LA Contraportada Oil-Free Air CompressorSafety Guidelines / Definitions Hazard Important Safety InstructionsRisk of Bursting Risk of Electrical Shock Risk of Burns Risk of Unsafe Operation Installation HOW to SET UP Your Unit SpecificationsGlossary Model NoGrounding Instructions Extension Cords Operation Auto/On/Off Switch Set switchPressure Switch not shown How to Use Your Unit To Check Safety Valve MaintenanceStorage Problem Cause Correction TroubleshootingProblem Cause Correction Problem Cause Correction Accessories Directives DE Sécurité Importantes Conservez CES Directives Directives DE Sécurité ImportantesDans un endroit propre, sec et bien aéré Ne faites pas fonctionner l’appareil àCommande pneumatique, des pneus et ’air, vous devez installer un régulateurCompresseur. Suivez la recommandation De fixer des outils ou des accessoiresDirectives de sécurité fournies sur Risque DE Chute Risque DE BrûluresPièces Mobiles Risque D’UTILISATION GlossaireEmplacement du compresseur d’air Installation Configuration DE Votre AppareilSpécifications Directives DE Mise À LA TerreProtection de la tension et du circuit FonctionnementApprenez à connaître votre compresseur d’air Description du fonctionnementComment l’arrêter Soupape de sûreté Si leManomètre de prise de courant Le Avant chaque fonctionnement Responsabilités du consommateur EntretienRangement Ne serrez pas trop. Si les fuites DépannageProblème Cause Correctif Ou ne modifiez pas le Ne percez pas, ne soudez pasRéservoir d’air sans quoi il Risque de s’affaiblir. LeTemporisation Garantie Complète DE Deux ANS Pour Usage Résidentiel AccessoiresInformation SUR LES Réparations 555326-7100 Conserve Estas Instrucciones Intrucciones DE Seguridad ImportantesCondensada del tanque, que Riesgo de estallidoProvoca óxido y adelgazamiento Del tanque de aceroAl que se conecta el compresor suministre Riesgo DE Caídas Riesgo DE QuemadurasRiesgo POR Piezas Móviles Riesgo DE Operación Insegura GlosarioInstalación Como Ubicar SU Unidad EspecificacionesModelo Nº Ubicación del compresor de aireCables prolongadores FuncionamientoVoltaje y protección del circuito Conozca su compresor de aireComo detenerla Cómo usar su unidadResponsabilidades del cliente MantenimientoAntes de cada arranque Almacenamiento Problema Causa Corrección Detección DE ProblemasNo ajuste demasiado. Si las No perforeMinutos para que el Información DE Servicio AccesoriosGarantía Completa DE DOS Años Para USO EN EL Hogar Otros Comuníquese con un centro de Servicio de B&DGUADALAJARA, JAL CULIACAN, SIN MONTERREY, N.LPUEBLA, PUE MEXICO, D.F641915-00,FSCP200 Compressor 641915-00,FSCP200 Compressor 641915-00,FSCP200 Compressor