SAFETY — Continued
GROUNDING INSTRUCTIONS
This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a
Note: The grounding adaptor, sketch (C), is prohibited in Canada by Canadian Electrical Code Part 1. Therefore, the instructions for its use are not applicable in Canada.
We recommend that you never disassemble the compressor or try to do any rewiring in the electrical system. Any repairs should be performed only by HITACHI Service Centers or other qualified service organizations. Should you be determined to make a repair yourself, remember that the green colored wire is the “grounding” wire. Never connect this green wire to a “live” terminal. If you replace the plug on the power cord, be sure to connect the green wire only to the grounding (longest) prong on a
If in doubt, call a qualified electrician and have the receptacle checked for ground.
Ground | Cover of Grounded |
Blade | Outlet box |
| (A) |
Cover of Grounded Outlet box
(B)
Adapter
Grounding Means
(C)
EXTENSION CORD
Use only
Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table shows the correct size to use depending on cord length and name plate ampere rating. If in doubt, use the next heavier gage. The smaller the gage number, the heavier the cord.
MINIMUM GAGE FOR CORD SETS
|
|
| Total Length of Cord in Feet (Meter) |
|
| |
|
|
| 0 – 25 | 26 – 50 | 51 – 100 | 101 – 150 |
|
|
| (0 – 7.6) | (7.9 – 15.2) | (15.5 – 30.5) | (30.8 – 45.7) |
Ampere | Rating |
| AWG |
|
| |
More | Not More |
|
|
|
| |
Than | Than |
|
|
|
| |
0 | – 6 | 18 | 16 | 16 | 14 | |
6 | – 10 | 18 | 16 | 14 | 12 | |
10 | – 12 | 16 | 16 | 14 | 12 | |
12 | – 16 | 14 | 12 | Not Recommended |