OfficeServ 7100 Installation Manual
CHAPTER 7. Connecting Stations and
Additional Equipment
This chapter describes how to connect various stations and additional equipment, such as analog/digital phones, door phones and door locks.
7.1 Connecting Stations
7.1.1 Cautions for Connecting Stations
Take the following cautions when connecting stations:
yDo not connect stations in weather conditions such as storm and lightning.
yDo not connect stations in a humid area.
yComply with the manual of the station and with this document when reconnecting stations or changing connections.
yConnect stations to a pair of #24 AWG or #26 AWG cables.
The distances between stations and the OfficeServ 7100 system are as follows:
Table 7.1 Distance Between Stations and the System
Installation Distance | Standards |
Digital Phone | Maximum 400 m(for AWG #24) |
|
|
Analog Phone | Maximum 1 km(for AWG #24) |
|
|
Door Phone | Maximum 400 m(for AWG #24) |
AOM | Maximum 400 m(for AWG #24) |
|
|
© SAMSUNG Electronics Co., Ltd. |