8.1.2 Safety Conditions
The building where the OfficeServ 7100 system is installed should have lightning rods and grounding to protect the system against lightning and electric leakage.
yCheck if the OfficeServ 7100 system is not inclined and is maintained horizontally.
yDo not place devices that may cause electromagnetic interference near the system.
yPlace a fire extinguisher near the system. Since spring coolers can seriously damage the system, use extinguishers such as Halor 1301 and Carbon Dioxide.
yMake sure that the input power of the OfficeServ 7100 system should be AC 230 V and do not use together with other electric devices, such as motors and compressors.
yCheck if the AC voltage switch of the PSU is properly set according to the voltage of the input power, 230 VAC.
yCheck if the grounding terminal on the rear panel of the system is properly connected to the external grounding.