OfficeServ 7100 Installation Manual
7.1.4.1 Connecting Boards to Ethernet
LIM/MGI/MGI64/MP10/MP11/4SWM board can be connected to Ethernet by using an Ethernet cable
yLIM
y4SWM
yMP10/11, MGI16/MGI64
Pin No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Function | Tx+ | Tx- | Rx+ | - | - | Rx- | - | - |
|
|
|
|
|
|
|
|
|
Figure 7.8 RJ-45 Port of Ethernet Connection Board
7.1.5 Connecting to a Door Phone and a Door Lock
Connect a door phone and a door lock to the OfficeServ 7100 system by using a Door Phone Interface Module(DPIM). Connect a pair of #24 AWG or #26 AWG cables to the LINE port of DPIM and the ports of 8DLI/16DLI2/8COMBO/4DLM board of the OfficeServ 7100 system.
Connecting to 8DLI/16DLI2/4DLM Boards
Pin No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Function | - | - | - | DLI TIP | DLI | - | - | - |
|
|
|
|
| RING |
|
|
|
|
|
|
|
|
|
|
|
|
Figure 7.9 RJ-45 Port of 8DLI/16DLI2/8COMBO/4DLM Boards (for Door Phone)
1)Connect the Door port of DPIM and the line port of DOOR BOX port.
2)When using an automatic door lock, connect the Lock port of the DPIM and the door phone contact point to the door lock.
The door lock contact point is designed to control
MMC Related
MMC 211 is used to assign call numbers to door phones.