DeWalt DWFP55130 instruction manual Installation, Grounding Instructions Fig, Extension Cords

Page 10

English

1.Set the On/Off switch (A) to OFF and unplug unit.

2.Allow the motor to cool.

3.Plug the power cord into the correct branch circuit receptacle.

4.Set the On/Off switch to ON position.

DUTY CYCLE (NOT SHOWN)

This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50% average duty cycle be maintained; that is, the air compressor pump should not run more than 5 minutes in any 10 minute period.

INSTALLATION

Grounding Instructions (Fig. 2)

WARNING: Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (J).

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

DANGER: Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

Extension Cords

If an extension cord must be used, be sure it is:

a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product

in good condition

no longer than 50' (15.2 m)

14 gauge (AWG) or larger. [Wire size increases as gauge number decreases. 12 AWG and 10 AWG may also be used. DO NOT USE 16 OR 18 AWG.)]

1.The cord set and plug (J) with this unit contains a grounding pin (L). This plug MUST be used with a grounded outlet (K).

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

FIG. 2

J

K

L

NOTICE: Risk of Property Damage. The use of an undersized extension cord will cause voltage to drop resulting in power loss to the motor and overheating. Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to its end. Attach additional lengths of hose as needed.

Voltage and Circuit Protection

Refer to the Voltage and Minimum Branch Circuit Requirements under

2.Ensure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

Pump/Motor Specifications.

WARNING: Risk of Overheating. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.

Voltage supply to circuit must comply with the National Electrical Code.

10

Image 10
Contents DWFP55130 Heavy Duty 200 psi Quiet Trim Compressor Specifications Pump/Motor SpecificationsDeclared Noise Emission Values per ISO Definitions Safety Guidelines Important Safety InstructionsHazard Could result in serious Attachments & Accessories TiresOver inflation of tires Injury and propertyInstructions paragraph Installation section Electrical GroundingAfter operation Air Tank Drain Valve For Future US Components FIGPressure Regulator Features FIG Tank under MaintenanceGrounding Instructions Fig InstallationPump/Motor Specifications Extension CordsLocation HOW to StopHOW to Start OperationTo Drain Tank Fig MaintenanceTo Check Safety Valve Fig Customer ResponsibilitiesService Information StorageGlossary Code Possible Cause Possible Solution Troubleshooting GuideTroubleshooting Codes It will weaken. The air tank can rupture or explodeCheck for proper fuse. You should use a time delay fuse Regulator is not adjusted correctlySwitch cut-in pressure Extension cord is wrong length or Tank pressure exceeds pressureFiche technique de la pompe/du moteur Fiche techniqueConserver CES Directives Définitions lignes directrices en Matière de sécuritéDirectives de sécurité importantes ManipulationLe débit d’air frais dans les Avertissement Risque D’ÉCLATEMENT Pourraient provoquer Relatives à la mise à la Terre sous InstallationDes pneus surgonflés Des blessures gravesOculaire conforme à la norme Avertissement Risque Associé AUX OnI /OffO Soupape de sûreté Manomètre du réservoir CE QUI Peut SE Comment L’ÉVITER ProduireInterrupteur marcheI/arrêtO Manomètre régulé Réservoir d’air Régulateur de pressionCaractéristiques FIG Directives relatives à la mise à la terre Fig Rallonges EmplacementProtection de la tension et du circuit Utilisation Utilisation De L’appareil FigVérification de la soupape de sûreté fig EntretienResponsabilités du client Vidange du réservoir FigRangement AccessoiresInformation sur les réparations Registre en ligne RéparationsGarantie complète d’un 1 an Glossaire Codes de dépannage Code Cause Probable Solution ProbableGuide de dépannage Avertissement risque d’éclatement. Ne pas percer leRallonges sous Installation ’avertissement concernant les vapeurs inflammables Valores de emisión de ruido declarados según ISO Especificaciones de la Bomba y el MotorEspecificaciones Instrucciones de seguridad importantes Definiciones Normas de seguridadConserve Estas Instrucciones Opere el compresor en Advertencia Riesgo DE Explosión Si no se siguen procedimientos de mantenimiento debidos, laInstrucciones de Conexión NeumáticosPuesta a tierra La no Tierra en InstalaciónUtilice siempre equipo Piezas en movimiento. Las ¿QUÉ Puede SUCEDER? Cómo Evitarlo ElevadasCaracterísticas FIG Instalación Instrucciones de conexión a tierra FigVoltaje y protección del circuito Cables prolongadoresLugar Operación Cómo utilizar su unidad figCómo verificar la válvula de seguridad Fig MantenimientoResponsabilidades del cliente Cómo drenar el tanque FigAccesorios AlmacenajeReparaciones Póliza de Garantía Registro en línea Garantía completa de un añoGlosario Problema Código Guía de detección de problemasCódigos de detección de problemas Código Causa Posible Solución PosibleRomper o explotar Cables prolongadores en la sección Instalación Copyright 2013, 2014 D Ewalt Power tools the yellow and black color schemeFollowing are trademarks For one or more