DeWalt DWFP55130 instruction manual Hazard

Page 4

English

Unattended operation of

• Always remain in attendance

 

 

this product could result in

with the product when it is

 

 

personal injury or property

operating.

 

 

damage. To reduce the

• Always turn off and unplug

 

 

risk of fire, do not allow

unit when not in use.

 

 

the compressor to operate

 

 

 

unattended.

 

 

 

 

HAZARD

 

 

 

DANGER: RISK TO BREATHING (ASPHYXIATION)

 

 

 

 

 

 

 

 

 

 

 

 

 

WHAT CAN HAPPEN

HOW TO PREVENT IT

• The compressed air directly

• Never use air obtained directly

 

 

from your compressor is not

from the compressor to supply

 

 

safe for breathing. The air

air for human consumption.

 

 

stream may contain carbon

The compressor is not

 

 

monoxide, toxic vapors,

equipped with suitable filters

 

 

or solid particles from the

and in-line safety equipment

 

 

air tank. Breathing these

for human consumption.

 

 

contaminants can cause

 

 

 

serious injury or death.

 

Exposure to chemicals

• Work in an area with good

 

 

in dust created by

cross ventilation. Read and

 

 

power sanding, sawing,

follow the safety instructions

 

 

grinding, drilling, and other

provided on the label or safety

 

 

construction activities may

data sheets for the materials

 

 

be harmful.

you are spraying. Always use

• Sprayed materials such as

certified safety equipment:

 

 

paint, paint solvents, paint

NIOSH/OSHA respiratory

 

 

remover, insecticides, weed

protection or properly fitting

 

 

killers, may contain harmful

face mask designed for use

 

 

vapors and poisons.

with your specific application.

HAZARD

WARNING: RISK OF BURSTING

Air Tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published Release # 02-108 concerning air compressor tank safety:

Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon several factors, some of which include operating conditions, ambient conditions, proper installations, field modifications, and the level of maintenance. The exact effect of these factors on air receiver life is difficult to predict.

If proper maintenance procedures are not followed, internal corrosion to the inner wall of the air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to suddenly and forcefully escape, posing risk of injury to consumers.

Your compressor air tank must be removed from service by the end of the year shown on your tank warning label.

The following conditions could lead to a weakening of the air tank, and result in a violent air tank explosion:

WHAT CAN HAPPEN

HOW TO PREVENT IT

• Failure to properly drain

• Drain air tank daily or after

condensed water from

each use. If air tank develops

air tank, causing rust and

a leak, replace it immediately

thinning of the steel air tank.

with a new air tank or replace

 

the entire compressor.

4

Image 4
Contents DWFP55130 Heavy Duty 200 psi Quiet Trim Compressor Specifications Pump/Motor SpecificationsDeclared Noise Emission Values per ISO Definitions Safety Guidelines Important Safety InstructionsHazard Attachments & Accessories Tires Over inflation of tiresCould result in serious Injury and propertyInstructions paragraph Installation section Electrical GroundingAfter operation Air Tank Drain Valve For Future US Components FIGPressure Regulator Features FIG Tank under MaintenanceInstallation Pump/Motor SpecificationsGrounding Instructions Fig Extension CordsHOW to Stop HOW to StartLocation OperationMaintenance To Check Safety Valve FigTo Drain Tank Fig Customer ResponsibilitiesService Information StorageGlossary Troubleshooting Guide Troubleshooting CodesCode Possible Cause Possible Solution It will weaken. The air tank can rupture or explodeRegulator is not adjusted correctly Switch cut-in pressure Extension cord is wrong length orCheck for proper fuse. You should use a time delay fuse Tank pressure exceeds pressureFiche technique de la pompe/du moteur Fiche techniqueDéfinitions lignes directrices en Matière de sécurité Directives de sécurité importantesConserver CES Directives ManipulationLe débit d’air frais dans les Avertissement Risque D’ÉCLATEMENT Relatives à la mise à la Terre sous Installation Des pneus surgonflésPourraient provoquer Des blessures gravesOculaire conforme à la norme Avertissement Risque Associé AUX CE QUI Peut SE Comment L’ÉVITER Produire Interrupteur marcheI/arrêtOOnI /OffO Soupape de sûreté Manomètre du réservoir Manomètre régulé Réservoir d’air Régulateur de pressionCaractéristiques FIG Directives relatives à la mise à la terre Fig Rallonges EmplacementProtection de la tension et du circuit Utilisation Utilisation De L’appareil FigEntretien Responsabilités du clientVérification de la soupape de sûreté fig Vidange du réservoir FigRangement AccessoiresInformation sur les réparations Registre en ligne RéparationsGarantie complète d’un 1 an Glossaire Code Cause Probable Solution Probable Guide de dépannageCodes de dépannage Avertissement risque d’éclatement. Ne pas percer leRallonges sous Installation ’avertissement concernant les vapeurs inflammables Valores de emisión de ruido declarados según ISO Especificaciones de la Bomba y el MotorEspecificaciones Instrucciones de seguridad importantes Definiciones Normas de seguridadConserve Estas Instrucciones Opere el compresor en Advertencia Riesgo DE Explosión Si no se siguen procedimientos de mantenimiento debidos, laNeumáticos Puesta a tierra La noInstrucciones de Conexión Tierra en InstalaciónUtilice siempre equipo Piezas en movimiento. Las ¿QUÉ Puede SUCEDER? Cómo Evitarlo ElevadasCaracterísticas FIG Instalación Instrucciones de conexión a tierra FigVoltaje y protección del circuito Cables prolongadoresLugar Operación Cómo utilizar su unidad figMantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Fig Cómo drenar el tanque FigAccesorios AlmacenajeReparaciones Póliza de Garantía Registro en línea Garantía completa de un añoGlosario Guía de detección de problemas Códigos de detección de problemasProblema Código Código Causa Posible Solución PosibleRomper o explotar Cables prolongadores en la sección Instalación Copyright 2013, 2014 D Ewalt Power tools the yellow and black color schemeFollowing are trademarks For one or more