MAINTENANCE

To Drain Tank (Fig. 1)

Customer Responsibilities

English

Drain Tank

Before

Daily or

See tank

each use

X

warning

 

 

after each

 

 

 

use

label

 

Check Safety Valve

X

 

 

 

 

 

 

 

 

Remove tank from service

 

 

X1

 

1- For more information, call

1-800-4-DE

WALT (1-800-

433-9258)

WARNING:Riskofunsafeoperation.Unitcyclesautomatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure.

NOTE: See Operation section for the location of controls.

To Check Safety Valve (Fig. 1)

WARNING: Risk of Bursting. If the safety valve does not work properly, over-pressurization may occur, causing air tank rupture or an explosion.

WARNING: Risk from Flying Objects. Always wear certified safety equipment: ANSI Z87.1 eye protection (CAN/CSA Z94.3) with side shields.

Before starting compressor, pull the ring on the safety valve (F) to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve.

12

WARNING: Risk of Unsafe Operation. Air tanks contain high pressure air. Keep face and other body parts away from outlet of drain. Use ANSI Z87.1 eye protection (CAN/CSA Z94.3) when draining as debris can be kicked up into face.

WARNING: Risk from noise. Always wear proper hearing protection during use. Under some conditions and duration of use, noise from this product may contribute to hearing loss.

NOTE: All compressed air systems generate condensate that accumulates in any drain point (e.g., tanks, filter, aftercoolers, dryers). This condensate contains lubricating oil and/or substances which may be regulated and must be disposed of in accordance with local, state, and federal laws and regulations.

WARNING: Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

NOTICE: Risk of Property Damage. Drain water from air tank may contain oil and rust which can cause stains.

1.Set the On/Off switch (A) to OFF.

2.Turn the regulator knob (D) counterclockwise to set the outlet pressure to zero.

3.Remove the air tool or accessory.

4.Place a suitable container under the drain valve to catch discharge.

5.Pull ring on safety valve (F) allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve (G) on bottom of tank.

7.After the water has been drained, close the drain valve. The air compressor can now be stored.

Image 12
Contents DWFP55130 Heavy Duty 200 psi Quiet Trim Compressor Pump/Motor Specifications SpecificationsDeclared Noise Emission Values per ISO Definitions Safety Guidelines Important Safety InstructionsHazard Attachments & Accessories Tires Over inflation of tiresCould result in serious Injury and propertyInstructions paragraph Installation section Electrical GroundingAfter operation For Future US Components FIG Air Tank Drain ValvePressure Regulator Features FIG Tank under MaintenanceInstallation Pump/Motor SpecificationsGrounding Instructions Fig Extension CordsHOW to Stop HOW to StartLocation OperationMaintenance To Check Safety Valve FigTo Drain Tank Fig Customer ResponsibilitiesService Information StorageGlossary Troubleshooting Guide Troubleshooting CodesCode Possible Cause Possible Solution It will weaken. The air tank can rupture or explodeRegulator is not adjusted correctly Switch cut-in pressure Extension cord is wrong length orCheck for proper fuse. You should use a time delay fuse Tank pressure exceeds pressureFiche technique de la pompe/du moteur Fiche techniqueDéfinitions lignes directrices en Matière de sécurité Directives de sécurité importantesConserver CES Directives ManipulationLe débit d’air frais dans les Avertissement Risque D’ÉCLATEMENT Relatives à la mise à la Terre sous Installation Des pneus surgonflésPourraient provoquer Des blessures gravesOculaire conforme à la norme Avertissement Risque Associé AUX CE QUI Peut SE Comment L’ÉVITER Produire Interrupteur marcheI/arrêtOOnI /OffO Soupape de sûreté Manomètre du réservoir Manomètre régulé Réservoir d’air Régulateur de pressionCaractéristiques FIG Directives relatives à la mise à la terre Fig Emplacement RallongesProtection de la tension et du circuit Utilisation Utilisation De L’appareil FigEntretien Responsabilités du clientVérification de la soupape de sûreté fig Vidange du réservoir FigAccessoires RangementInformation sur les réparations Réparations Registre en ligneGarantie complète d’un 1 an Glossaire Code Cause Probable Solution Probable Guide de dépannageCodes de dépannage Avertissement risque d’éclatement. Ne pas percer leRallonges sous Installation ’avertissement concernant les vapeurs inflammables Especificaciones de la Bomba y el Motor Valores de emisión de ruido declarados según ISOEspecificaciones Definiciones Normas de seguridad Instrucciones de seguridad importantesConserve Estas Instrucciones Opere el compresor en Advertencia Riesgo DE Explosión Si no se siguen procedimientos de mantenimiento debidos, laNeumáticos Puesta a tierra La noInstrucciones de Conexión Tierra en InstalaciónUtilice siempre equipo Piezas en movimiento. Las ¿QUÉ Puede SUCEDER? Cómo Evitarlo ElevadasCaracterísticas FIG Instalación Instrucciones de conexión a tierra FigCables prolongadores Voltaje y protección del circuitoLugar Operación Cómo utilizar su unidad figMantenimiento Responsabilidades del clienteCómo verificar la válvula de seguridad Fig Cómo drenar el tanque FigAlmacenaje AccesoriosReparaciones Póliza de Garantía Registro en línea Garantía completa de un añoGlosario Guía de detección de problemas Códigos de detección de problemasProblema Código Código Causa Posible Solución PosibleRomper o explotar Cables prolongadores en la sección Instalación Power tools the yellow and black color scheme Copyright 2013, 2014 D EwaltFollowing are trademarks For one or more