Porter-Cable C2004, N034163 instruction manual Motor Overload Protector not shown, How to Stop

Page 11

Drain Valve: The drain valve is located at the base of the

 

 

 

 

air tank and is used to drain condensation at the end of

 

 

each use.

 

 

Drain

Check Valve: When the air compressor is operating, the

 

 

Valve

check valve is "open", allowing compressed air to enter

 

 

 

the air tank. When the air compressor reaches "cut-out"

 

pressure, the check valve "closes", allowing air

 

 

 

pressure to remain inside the air tank.

 

 

 

Motor Overload Protector (not shown): The

 

 

 

motor has a thermal overload protector. If the motor

 

 

 

overheats for any reason, the overload protector

Check Valve

 

will shut off the motor. The motor must be allowed

 

 

 

 

to cool down before restarting. To restart:

 

 

 

1.Set the On/Off lever to "Off" and unplug unit.

2.Allow the motor to cool.

3.Plug the power cord into the correct branch circuit receptacle.

4.Set the Auto/Off lever to "On" position.

Quick-Connect Body: The quick connect body accepts industrial quick connect plugs. The two quick connect bodies allow the use of two tools at the same time.

How to Use Your Unit

How to Stop

1.Set the On/Off switch to "Off".

2.Unplug unit when not in use.

Before Starting

Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.

Before Each Start-Up

1.Set the On/Off switch to "Off".

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Turn the regulator knob counterclockwise to set the outlet pressure to zero.

4.Attach hose and accessories.

Risk of unsafe operation. Firmly grasp air hose in hand when installing or disconnecting to prevent hose whip.

Risk of unsafe operation. Do not use damaged or worn

accessories.

NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

Risk of property damage. Compressed air from the unit may contain water­ condensation and oil mist. Do not spray unfil­tered­ air at an item that could be damaged by moisture. Some air tools and accessories may require filtered air. Read the instruc­tions­ for the air tools and accessories.

11 - ENG

Image 11
Contents C2004 Hazard Safety Guidelines DefinitionsImportant Safety Instructions Risk of Bursting Risk of Electrical Shock What can happen How to prevent itAttachments & accessories TiresRisk from Moving Parts Risk from Flying ObjectsRisk of Hot surfaces Risk of Falling Risk of Unsafe OperationModel No C2004 SpecificationsRisk from noise What can happen How to prevent it Declared Noise Emission Values per ISOGlossary AssemblyInstallation HOW to SET UP Your UnitVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor Before Starting Before Each Start-Up How to StopMotor Overload Protector not shown Customer Responsibilities MaintenanceTo Check Safety Valve How to StartTo Replace Regulator Service and AdjustmentsStorage Replacement Parts Service and RepairsProblem Cause Correction AccessoriesTroubleshooting Description Overload Protection Full One Year Warranty Risque d’explosion ou d’incendie Mesures DE Sécurité DéfinitionsConsignes DE Sécurité Importantes Indique un dangerRisque Repiratoire Asphyxie Placer par un nouveau réservoir d’air Risque d’ÉclatementBlessures graves et des Accessoires Pneus Des pneus surgonflés Pourraient provoquer desDirectives relatives à la mise Mise à la terre électrique leRisque associÉ À utilisation Risque associÉ auxPiÈces mobiles Modèle no C2004 Risque associÉ au bruitDéballage Cycle DE ServiceLexique AssemblageRallonges Emplacement du compresseur dairMontage DE Lappareil Protection contre la surtension et protection du circuit Description du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Arrêt de lappareil Utilisation de lappareilProtecteur de surcharge du moteur non illus Responsabilités du client EntretienVidange du réservoir Vérification de la soupape de sûretéPour remplacer le régulateu Entretien ET RéglagesPièces DE Rechange Entretien ET Réparation ServiceRangement Dépannage AccessoiresRemarque Ajustez Intitulé «Description duFonctionnement» de la Surcharge du moteur Garantie complète d’un 1 an Peligro Definiciones DE Normas DE SeguridadInstrucciones Importantes DE Seguridad Riesgo Respiratorio asfixia Elementos y accesorios Riesgo de explosiónPuesta a tierra La no colo NeumáticosRiesgo por piezas móviles Riesgo DE superficies calientesRiesgo DE Caídas Riesgo de operación inseguraModelo Nº C2004 Cuadro DE EspecificacionesValores de emisión de ruido declarados según ISO Riesgo por ruidosInstalación GlosarioCiclo DE Servicio EnsambladoProtección del voltaje y del circuito Cables de extensión eléctricaDescripción de operaciones OperaciónConozca su compresor de aire Cómo detenerla Cómo utilizar su unidadProtector de sobrecalentamiento del motor Cómo poner en marcha Cómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadPara reemplazar el regulador Servicio Y AjustesAlmacenaje Piezas DE Repuesto Mantenimiento Y Reparaciones ServicioAccesorios Corrección Guía DE Diagnóstico DE ProblemasLas instrucciones de Sobrecalentamiento Consulte Protector deIdentificación DEL Producto Sello o firma del Distribuidor Póliza de GarantíaGarantía completa de un año Para Otras Localidades Page Page Page Highway 45 North Jackson, TN 888