ELECTRICAL REQUIREMENTS AND SAFETY
GROUNDING INSTRUCTIONS
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides a path of least resistance for electric currents and reduces the risk of electric shock. This tool is equipped with an electrical cord that has an
DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the receptacle, have the proper receptacle installed by a qualified electrician.
IMPROPER CONNECTION of the equipment grounding conductor can result in risk of electric shock. The conductor with the green insulation (with or without yellow stripes) is the equipment grounding conductor.
If repair or replacement of the electrical cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.
CHECK with a qualified electrician or service person if you do not completely understand the grounding instructions, or if you are not certain the tool is properly grounded.
USE only
GUIDELINES FOR EXTENSION CORDS
USE THE PROPER EXTENSION CORD. Make sure your extension cord is in good condition. Use an extension cord heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power, overheating and burning out of the motor. The table on the right shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
Make sure your extension cord is properly wired and in good condition. Always replace a damaged extension cord or have it repaired by a qualified technician before using it. Protect your extension cords from sharp objects, excessive heat and damp or wet areas.
Use a separate electrical circuit for your tool. This circuit must not be less than #12 wire with a 20 A
or a #14 wire with a 15 A
Fig. 1 shows a three-pronged electrical plug and receptacle that has a grounding conductor. If a properly grounded receptacle is not available, an adapter (Fig. 2) can be used to temporarily connect this plug to a two- contact grounded receptacle. The adapter (Fig. 2) has a rigid lug extending from it that MUST be connected to a permanent earth ground, such as a properly grounded receptacle box.
WARNING
In all cases, make certain the receptacle is properly grounded. If you are not sure, have a qualified electrician check the receptacle.
WARNING
This tool is for indoor use only. Do not expose to rain or use in damp locations.
Fig. 1 |
| Grounding Prong |
| Properly Grounded |
| |
Fig. 2 | Grounding Lug |
Make sure this is connected to a known ground.
Adapter Receptacle
CAUTION
This tool must be grounded while in use to protect the operator from electric shock.
MINIMUM GAUGE FOR EXTENSION CORDS (AWG)
(When using 120 volts only)
Ampere Rating |
| Total length of Cord | |||
More Than | Not More Than | 25ft. | 50ft. | 100ft. | 150ft. |
0 | 6 | 18 | 16 | 16 | 14 |
6 | 10 | 18 | 16 | 14 | 12 |
10 | 12 | 16 | 16 | 14 | 12 |
12 | 16 | 14 | 12 | Not Recommended |
– 6 –