Installation, Start-Up, Service Instructions
General
Safety Considerations
Installation
Physical Data 50PSH, PSV, PSD018-070 Units
Typical Installation 50PSH Unit
BSP
ASP
CAP
Code Return Discharge CSP
50PSV Dimensional Data
HWR Hot Water Reheat Left Hand Right Hand
A50-7846ef
Back Discharge
Side Discharge
Mount the Unit
Install Condensate Drain
Trap Condensate Drain Connection
Material
Water Quality Guidelines
Open Loop and Recirculating Well
Metal Hose Minimum Bend Radii
Typical Ground-Water Piping Installation
Supply/Return Hose Kit
Wire Field Power Supply
Description of Operation LED Alarm Relay
Complete C Controller Fault Codes
Trans
Astat
BMC
Wire Number
Compr
Yellow RED
LWT
ECM
Units with ECM, Complete C and LON Controller 460
A50-8363
Units with ECM, Deluxe D and LON Controller 460
A50-8364
Mves
SAT
Hpws
WHSP-OPEN
8354
A50
8356
LWT
Wshp Open Control
A50-8380
50PSH, PSV, PSD Electrical Data PSC High-Static Motor
50PSH, PSV, PSD Electrical Data PSC Motor
50PSH, PSV, PSD Electrical Data, ECM Motor
Low Voltage Field Wiring
Wire Field Controls
A50-8441
Rnet Wiring Specifications
A50-8442
Field-Supplied Sensors for Wshp Open Controller
Wire Terminal
Rnet Wiring
Operate ECM Interface Board
A50-8443
ECM Blower Motor Performance Data
Setting Size
Unit Airflow CFM Speed Size
Rated MIN FAN
Coil Units with Reheat ESP Loss Face Velocity
FPM
Deluxe D Control Jumper Settings
Complete C Control Jumper Settings
PRE-START-UP
Field Selectable Inputs
DIP Switch Block S2 Accessory 2 Relay Options
DIP Switch Block S2 Accessory 1 Relay Options
Humidistat/Dehumidistat Logic Deluxe D DIP Switch Settings
VAC
A50-8145
HWR Operating Modes
START-UP
Unit Start-Up Cooling Mode
Operating Limits
Operating Limits 50PSH, PSV, PSD Units
Water Temperature Change Through Heat Exchanger
Unit Start-Up Heating Mode
Cooling Heating Water Flow Rate GPM Rise F Drop F
Water Flow Temp
GPM/ton Pressure Heat Cooling Rise Drop Psig
Flow
Flow
BACview6 Display Interface
Unit Start-Up with Wshp Open Controls
50PSH, PSV, PSD Coaxial Water Pressure Drop
50PSH, PSV, PSD Water Water Temperature F Flow
Unit Size
GPM
Antifreeze Percentages by Volume
Approximate Fluid Volume gal Per 100 Ft of Pipe
Operation
Units with Aquazone Complete C Control
Units with Wshp Open Multiple Protocol
Units with HWR Option
Page
Page
Off
LED Status Description of Operation Alarm Relay
Complete C and Deluxe D Board System Test
LED Code Fault Description
Complete C Control LED Code Fault Descriptions
Aquazone Deluxe D Control LED Indica
Description Status LED Test LED
Service
Refrigerant Charging
Troubleshooting
Air Coil Fan Motor Removal
Replacing the Wshp Open Controller’s Bat
FP1 and FP2 Thermistor Location
Page
Fault Description Solution
ECM Troubleshooting
A50-8448
ECM Pin Connectors
A50-8447
ECM Troubleshooting Flow Diagram
Fault Heating Cooling Possible Cause Solution
Wshp Troubleshooting
Good Practices
TXV
Code 7 Auto Resetting
Condensate Fault
No Fault Code Shown
Code
High Head Pressure
Temperature in Heating
Low Suction Pressure
Low Discharge Air
Appendix a Wshp Open Screen Configuration
Appendix a Wshp Open Screen Configuration
Weekly Schedule
Set Points
Exception
Schedules 1
Test
Appendix a Wshp Screen Open Configuration
Service
Screen Name
Configuration Service
Point Name Password Editable Range Default Level
Linkage
Alarm
Page
Page
Copyright 2009 Carrier Corporation
II. START-UP
50PSH,PSV,PSD START-UP Checklist
Cooling Cycle Analysis
Heating Cycle Analysis
A50-8494
A50-8495