Carrier PSD006-070, 50PSH instruction manual 50PSV Dimensional Data

Page 6

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER

 

 

 

 

 

 

 

 

 

RETURN

 

 

 

 

 

 

 

 

WATER CONNECTIONS

 

CONNEC-

ELECTRICAL

DISCHARGE CONNECTION (in.)

CONNECTION (in.)

 

 

 

 

 

 

 

 

TIONS (in.) -

KNOCKOUTS

 

DUCT FLANGE INSTALLED

 

USING RETURN

 

OVERALL

 

 

 

(in.)

 

 

 

 

 

 

 

 

 

 

 

 

UNITS WITH

 

(in.)

 

 

 

(±0.10 in.)

 

 

AIR OPENING

 

50PSV

 

CABINET

 

 

 

 

 

 

 

 

HWR

 

 

 

 

 

 

 

 

 

(±0.10 in.)

 

 

 

(in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

K

L

 

 

 

 

 

 

 

 

 

 

SIZE

 

 

 

 

1

2

3

4

 

5

Loop

 

1

2

1/2

1/2

3/4

M

N

O

P

Q

R

S

T

 

U

 

 

 

 

 

 

 

 

 

 

 

HWG

 

 

Cond

Cond

Cond

 

 

 

 

 

 

 

 

F

G

 

H

Water

FPT

 

 

 

 

 

(LH

 

Supply

Supply

(RH

 

Return

Return

 

 

 

A

 

B

C

D

E

 

FPT

 

Loop

Loop

Low

Ext

Power

rtrn)

 

Width

Depth

rtrn)

 

Depth

Height

 

 

 

Width

 

Depth

Height

In

Out

HWG

HWG

Conden-

 

 

In D

Out E

Voltage

Pump

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In

Out

 

sate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

006,009,

22.4

 

21.6

34.5

3.7

9.7

N/A

N/A

 

7.4

1/2

N/A

N/A

N/A

3.8

6.3

8.8

6.7

6.3

9.0

9.0

6.7

2.3

17.1

15.3

 

1.0

012

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018

22.4

 

25.6

44.6

2.1

10.0

13.9

16.9

 

7.8

3/4

1/2

2.1

10.0

3.6

6.1

8.6

7.2

5.8

14.0

14.0

4.9

2.2

21.1

23.2

 

1.0

024,

22.4

 

25.6

48.5

2.1

10.0

13.9

16.9

 

7.8

3/4

1/2

5.26

13.13

3.6

6.1

8.6

7.2

5.8

14.0

14.0

4.9

2.2

21.1

27.2

 

1.0

030

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

25.4

 

30.6

50.5

3.4

10.8

15.6

18.9

 

7.8

3/4

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

27.2

 

1.0

042,

25.4

 

30.6

54.5

3.4

10.8

15.6

18.9

 

7.8

1

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

31.2

 

1.0

048

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060,

25.4

 

30.6

58.5

3.4

10.8

15.6

18.9

 

7.8

1

1/2

5.96

13.13

3.6

6.1

8.6

6.4

6.3

18.0

18.0

5.3

2.2

26.1

35.2

 

1.0

070

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Condensate is 3/4-in. FPT copper and is switchable from side to front.

2.Vertical unit shipped with filter bracket only, extending from unit 2.5-in. This bracket should be removed for return duct connection.

3.Discharge flange field installed.

4.Shaded areas are recommended service areas, not required.

 

 

 

 

 

LEGEND

PSC BLOWER AIRFLOW

 

ASP

Alternate Service Panel

 

CONFIGURATION

 

BSP

Blower Service Panel

 

 

 

 

CAP

Control Access Panel

CODE

RETURN

DISCHARGE

 

CSP

Compressor Service Panel

L

Left

Top

 

FPT

Female Pipe Thread

 

 

 

 

R

Right

Top

 

HWG — Hot Water Generator

 

HWR — Hot Water Reheat

 

 

 

 

LH

Left Hand

 

 

 

 

RH

Right Hand

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R - Configuration Right Return / Top Discharge

L - Configuration Left Return / Top Discharge

 

 

 

- Top View

 

 

 

- Top View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Right Return

-Air Coil Opening

-Right Side View

Left Return

-Air Coil Opening

-Left Side View

Fig. 3 — 50PSV Dimensional Data

6

Image 6
Contents Installation, Start-Up, Service Instructions ContentsSafety Considerations InstallationGeneral Physical Data 50PSH, PSV, PSD018-070 Units Typical Installation 50PSH Unit CAP ASPBSP Code Return Discharge CSP50PSV Dimensional Data A50-7846ef HWR Hot Water Reheat Left Hand Right HandSide Discharge Back DischargeInstall Condensate Drain Mount the UnitTrap Condensate Drain Connection Water Quality Guidelines Open Loop and Recirculating WellMaterial Typical Ground-Water Piping Installation Metal Hose Minimum Bend RadiiWire Field Power Supply Supply/Return Hose KitTrans Complete C Controller Fault CodesDescription of Operation LED Alarm Relay AstatCompr Wire NumberBMC Yellow REDECM LWTA50-8363 Units with ECM, Complete C and LON Controller 460A50-8364 Units with ECM, Deluxe D and LON Controller 460SAT HpwsMves WHSP-OPEN A50 83548356 LWT A50-8380 Wshp Open Control50PSH, PSV, PSD Electrical Data PSC Motor 50PSH, PSV, PSD Electrical Data PSC High-Static Motor50PSH, PSV, PSD Electrical Data, ECM Motor Wire Field Controls Low Voltage Field WiringA50-8442 Rnet Wiring SpecificationsA50-8441 Field-Supplied Sensors for Wshp Open ControllerOperate ECM Interface Board Rnet WiringWire Terminal A50-8443Setting Size ECM Blower Motor Performance DataCoil Units with Reheat ESP Loss Face Velocity Rated MIN FANUnit Airflow CFM Speed Size FPMPRE-START-UP Complete C Control Jumper SettingsDeluxe D Control Jumper Settings Field Selectable InputsHumidistat/Dehumidistat Logic Deluxe D DIP Switch Settings DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options VACHWR Operating Modes A50-8145Operating Limits Unit Start-Up Cooling ModeSTART-UP Operating Limits 50PSH, PSV, PSD UnitsCooling Heating Water Flow Rate GPM Rise F Drop F Unit Start-Up Heating ModeWater Temperature Change Through Heat Exchanger Water Flow TempGPM/ton Pressure Heat Cooling Rise Drop Psig Flow Flow Unit Start-Up with Wshp Open Controls BACview6 Display InterfaceUnit Size 50PSH, PSV, PSD Water Water Temperature F Flow50PSH, PSV, PSD Coaxial Water Pressure Drop GPMOperation Approximate Fluid Volume gal Per 100 Ft of PipeAntifreeze Percentages by Volume Units with Aquazone Complete C ControlUnits with HWR Option Units with Wshp Open Multiple ProtocolPage Page LED Status Description of Operation Alarm Relay Complete C and Deluxe D Board System TestOff Aquazone Deluxe D Control LED Indica Complete C Control LED Code Fault DescriptionsLED Code Fault Description Description Status LED Test LEDService Air Coil Fan Motor Removal TroubleshootingRefrigerant Charging Replacing the Wshp Open Controller’s BatFP1 and FP2 Thermistor Location Page ECM Troubleshooting Fault Description SolutionECM Pin Connectors A50-8448ECM Troubleshooting Flow Diagram A50-8447Good Practices Wshp TroubleshootingFault Heating Cooling Possible Cause Solution TXVNo Fault Code Shown Condensate FaultCode 7 Auto Resetting CodeLow Suction Pressure Temperature in HeatingHigh Head Pressure Low Discharge AirAppendix a Wshp Open Screen Configuration Appendix a Wshp Open Screen Configuration Exception Set PointsWeekly Schedule Schedules 1Appendix a Wshp Screen Open Configuration ServiceTest Configuration Service Point Name Password Editable Range Default LevelScreen Name Alarm LinkagePage Page Copyright 2009 Carrier Corporation 50PSH,PSV,PSD START-UP Checklist II. START-UPA50-8494 Heating Cycle AnalysisCooling Cycle Analysis A50-8495