Carrier 50TFQ008-012 specifications Index, Mounting Compressor Unit

Page 54

INDEX

Access panels

18

 

 

 

 

Barometric flow capacity

20

 

Carrier Comfort Network

14

 

Charging chart, refrigerant

48, 49

Clearance

3, 6

 

 

 

 

 

CO2 sensor

 

 

 

 

 

 

Configuration

 

25

 

 

 

Settings

23, 25

 

 

 

 

 

Compressor

 

 

 

 

 

 

Mounting

44

 

 

 

 

 

Rotation

44

 

 

 

 

 

 

Condensate drain

 

 

 

 

 

Cleaning

47

 

 

 

 

 

Location

3

 

 

 

 

 

 

Control circuit

 

 

 

 

 

 

Wiring

 

12

 

 

 

 

 

 

Wiring raceway

 

12

 

 

 

Convenience outlet

10, 11, 13

 

Defrost board

12, 13

 

 

 

Demand control ventilation

24

Dehumidification

25

 

 

Dimensions 2, 6

 

 

 

 

Ductwork

3

 

 

 

 

 

 

EconoMi$er2

18

 

 

 

 

Components

18

 

 

 

 

4 to 20 mA control

20

 

 

Wiring

 

20

 

 

 

 

 

 

EconoMi$er IV

18-25

 

 

Components

18

 

 

 

 

Damper

24

 

 

 

 

 

 

Dry bulb changeover

21

 

 

Enthalpy changeover

22

 

 

Inputs and outputs

 

53

 

 

Troubleshooting

 

49, 50

 

 

Wiring

 

19

 

 

 

 

 

 

Electrical connections

7

 

 

Electrical data

8-11

 

 

 

Electric heat

8

 

 

 

 

 

Enthalpy changeover set points

23

Factory-installed options

12-25

Convenience outlet

13

 

 

EconoMi$er2 18-20

 

 

EconoMi$er IV

 

18-25

 

 

Manual outdoor air damper

13

Novar controls

13

 

 

 

PremierLink™ controls

14-16

Filter

 

 

 

 

 

 

 

 

Cleaning

48

 

 

 

 

 

Installation

19

 

 

 

 

 

Size

5

 

 

 

 

 

 

 

Freeze protection thermostat

5, 48

Heat anticipator settings 12, 13

High flow valves

 

44

 

 

 

High pressure switch

5, 48

 

Horizontal units

3

 

 

 

 

Indoor air quality

 

14, 22

 

 

Indoor coil

5

 

 

 

 

 

 

Cleaning

47

 

 

 

 

 

Indoor fan motor

 

5

 

 

 

Lubrication

48

 

 

 

 

Motor data

26

 

 

 

 

 

Performance

28-43

 

 

 

Pulley adjustment

26

 

 

Pulley setting

 

5, 27

 

 

 

Speed

5

 

 

 

 

 

 

Low pressure switch

5, 48

 

Manual outdoor air damper

13

Mounting

 

 

 

 

 

 

 

Compressor

44

 

 

 

 

Unit

3

 

 

 

 

 

 

 

Novar controls

 

13

 

 

 

Operating sequence

 

 

 

Cooling

45

 

 

 

 

EconoMi$er2 45-47

 

 

EconoMi$er IV

45

 

 

Heating

45

 

 

 

 

Outdoor air hood

14, 19

 

 

Outdoor air inlet screens

44

 

Cleaning

48

 

 

 

 

Outdoor coil

5

 

 

 

 

Cleaning

47

 

 

 

 

Outdoor fan

5

 

 

 

 

Adjustment

48

 

 

 

Physical data

5

 

 

 

 

Potentiometer

22

 

 

 

Power supply

 

 

 

 

 

Wiring

 

7

 

 

 

 

 

PremierLink controls

14-16

 

Pressure, drop

 

 

 

 

Electric heat

27

 

 

 

Return air

20

 

 

 

 

Outdoor air

20

 

 

 

Pre-start-up 44

 

 

 

 

Pressure switches

 

 

 

 

High pressure

5

 

 

 

Low pressure

5

 

 

 

Refrigerant

 

 

 

 

 

Charge

 

5, 48, 49

 

 

 

Type

5

 

 

 

 

 

 

Refrigerant service ports

44

 

Replacement parts

48

 

 

Return air filter

5, 44

 

 

Return air temperature sensor

22

Rigging unit

3, 4

 

 

 

Roof curb

 

 

 

 

 

 

Assembly

1

 

 

 

 

Dimensions

2

 

 

 

 

Connector package

2

 

 

Leveling tolerances

3

 

 

Weight

 

5

 

 

 

 

 

Safety considerations

1

 

 

Safety relief

45

 

 

 

 

Service

47-49

 

 

 

 

Service ports

44

 

 

 

Slab mount

3

 

 

 

 

Start-up 44-47

 

 

 

 

Start-up checklist

CL-1

 

 

Supply-air temperature sensor

14, 21

Thermostat

12, 24

 

 

 

Troubleshooting

49-53

 

 

Ventilation

45

 

 

 

 

Weight

 

 

 

 

 

 

 

Corner

 

6

 

 

 

 

 

EconoMi$er IV

5, 6

 

 

Unit

4-6

 

 

 

 

 

Wiring

 

 

 

 

 

 

 

4 to 20 mA control

20

 

 

EconoMi$er2

20

 

 

 

EconoMi$er IV

19

 

 

Power connections

7

 

 

PremierLink

16

 

 

 

Thermostat

12

 

 

 

Unit

51

 

 

 

 

 

 

Copyright 2005 Carrier Corporation

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

Catalog No. 04-53500019-01

Printed in U.S.A.

Form 50TFQ-9SI

Pg 54

9-05

Replaces: 50TFQ-7SI

Tab

5a

5a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 54
Contents Contents Safety ConsiderationsInstallation Roof Curb Details Unit Leveling Tolerances Rigging Details Physical Data Unit Size 50TFQBase Unit Dimensions Make Electrical Connections Electric Heating Capacities Electrical Data Units Without Electrical Convenience OutletSIZE† Electrical Data Units With Electrical Convenience Outlet 81/2 TonsOFM IFM Heat SIZE† Unit Size Adjust Factory-Installed Options Heat Anticipator Settings 208/230 460 575Stage Outdoor-Air Hood Details PremierLink Sensor Usage PremierLink ControllerPremierLink Controller Installed For Differential EconoMi$er IV Component Locations Outdoor-Air Hood Construction EconoMi$er2 with 4 to 20 mA Control Wiring Supply Air Sensor Temperature Resistance Values EconoMi$er IV Sensor UsageEconoMi$er IV Controller Potentiometer LED Locations Enthalpy Changeover Set Points Page CO2 Sensor Standard Settings UrationTypical Belt-Drive Motor Mounting for Size Size 008 Fan Motor PerformanceFan Rpm at Motor Pulley Settings Electric Heater Static Pressure* in. wg 50TFQ008-0122300 519 567 External Static Pressure in. wgRpm Bhp Watts 2250 511 538 2400 534 6302400 534 630 611 798 678 974 Rpm Bhp Watts 2250 511 538 591 697 660 8642300 519 567 597 729 666 900 2500 550 698 624 872Airflow 3900 4000 4100 4200 4250 Rpm Bhp Watts 2550 557 733 631 9103800 Rpm Bhp Watts 25503300 679 1438 741 1663 798 1892 851 2126 3100 646 1217 711 1428 770 1645 825 18693200 662 1324 726 1542 784 1765 838 1994 3400 695 1558 756 1790 812 20253200 583 712 648 865 Rpm Bhp Watts 3000 556 604 623 748 684 8913100 569 656 636 805 3300 597 770 661 9293800 668 1116 726 1299 779 1481 828 1662 3600 639 967 700 1140 754 1312 805 14843700 654 1040 713 1218 767 1395 817 1571 3900 683 1197 739 1385 792 1572 840 17584200 726 1462 780 1665 3500 625 898 687 1066 742 1233 794 14003900 683 1197 739 1385 792 1572 1132 3555 45002400 483 534 570 705 Rpm Bhp Watts 2250 465 459 555 6212300 471 483 560 648 2500 495 588 581 7672400 483 534 570 705 644 880 Rpm Bhp Watts 2250 465 459 555 621 629 7862300 471 483 560 648 634 817 2500 495 588 581 767 653 948Airflow Rpm Bhp Watts 2550 501 617 586 799 658 983 3800 662 17053900 675 1828 Airflow 3200 549 637 614 783 676 936 Rpm Bhp Watts 3000 523 541 592 680 657 8253100 536 587 603 730 666 879 3300 562 689 626 839Airflow General Notes for FAN Performance Data Tables PRE-START-UP START-UPOperating Sequence DX Cooling Temperature Control Example Service Cleaning Outdoor CoilLubrication Troubleshooting Cooling Charging Chart, 50TFQ009Page Typical Unit Wiring Schematic 208/203-3-60 Unit Shown Heating and Cooling Troubleshooting EconoMi$er IV Input/Output Logic Demand Control EnthalpyTerminal† Index Mounting Compressor UnitPage START-UP Checklist Preliminary InformationIII. START-UP