CONNECTING

THE MAIN

POWER SOURCE

IMPORTANT: Always refer to the wiring diagrams that came with your saw before making electrical connec- tions. The diagrams show the minimum size main power cable required for your saw, and the most accurate electri- cal component information.

WARNING: Electrical hazard

Before performing any work on this product, dis- connect and lock out electrical power sources to prevent injury from unexpected energization or start-up. A lockable device has been provid- ed to isolate this product from potentially haz- ardous electricity.

WARNING: Improper installation, oper- ation, or servicing may result in equipment damage or personal injury.

This equipment should only be installed, adjust- ed, and serviced by qualified technical person- nel who are familiar with the construction, oper- ation, and potential hazards of this type of machine.

All wiring, disconnects, and fuses should be installed by qualified electrical technicians in accordance with electrical codes in your region. Always maintain a safe ground. Do not operate the equipment at power levels other than what is specified on the machine serial tag and data plate.

1 Open the servo saw’s electrical enclosure. Turn the disconnect dial on the door to the OFF or O position and open the door.

2 Insert the main power wire through the knockout in the side of the enclosure. Secure the wire with a rubber compression fitting or strain relief.

3 Connect the power wires to the terminals indicated on the wiring diagram that came with your machine.

4 Check every terminal screw to make sure wires are secure. Gently tug each wire. If a wire is loose, use a screwdriver to tighten the terminal.

5 Connect the ground wire to either grounding point shown in the diagram.

3-6

INSTALLATION

CTS Saw

UGE058/0803

Image 24
Contents Traveling Saw Date Document Number Table of Contents Troubleshooting Introduction Purpose User Guide HOW the User Guide is OrganizedYour Responsibility AS a User Read this SO no ONE Gets Hurt Read this SO no ONE Gets Hurt HOW to USE Lockout Device Turn the rotary disconnect switch to OFF or O positionPage Description What is Typical ApplicationsHOW the CTS SAW Works SAW Works Features CTS SAWSpecifications Optional Equipment Left to right machine operationPage Installation Unpacking the Boxes Carefully uncrate the saw and its componentsPreparing for Installation You need these tools for installationPositioning the CTS SAW Move the saw into position. Place the saw in posiDetermine the best distance from the belt puller to Position the SAW Connecting Main Power Source Installing the Encoder Installing the SAW Blades Remove the hex nutPreparing for Testing Testing the InstallationPage Operation SAW Control Control Features Blade Height Adjustment Machine Frame Support SystemUpper Clamp Adjustment Power SupplyTo remove and/or adjust each clamp assembly Control PanelsPneumatic Cylinder Operation Electrical Operation Machine Lubrication System InspectionBlade Replacement Wait at least five minutes for the blade to stop completelyChip Collection Shrouds Blower Connection Maintenance Maintenance Features Maintenance Maintenance Overview Preventative Maintenance ScheduleChecking saw blades Inspecting the blade mounting hardwareWeekly Checking Blades Checking Electrical Connections Open the electrical enclosure Close the electrical enclosure doorTroubleshooting Before Beginning FEW Words of CautionIdentifying Cause of a Problem Electrical Problems Symptom Possible cause SolutionProduct Quality Problems Incorrect blade designIncorrect cooling ExtrudateProblem Puller problem Counter problemRodless cylinder problem Solenoid problemChecking Servo Amplifier Checking the Encoder Check all connectionsCheck the encoder cable for damage. If neces Check the encoder itself. There should be no playWE’RE Here to Help From outside the United States, callAppendix A-2 Conair Servo Traveling Saw Soft KeysNumeric keys Fixed Function Keys at BottomLCD Screen Contents Power Up Sequence Starting CommsMain Screen Length CounterOn/Off Softkey Reset Softkey Total SoftkeyTotal Screen Exit SoftkeyLength Softkey Enter or Delete?Homing Home SeekHome Already Menu Area Maint. SoftkeyMaint. Area R c t n S o f t k e yChange Softkey S o f t k e y Time SoftkeyCycles Softkey B l e S o f t k e yT u r n S o f t k e y Acceptable range is 120.00-1800.00 ipmV a n c e S o f t k e y 20%Error Message Menu Area Factory SoftkeyTable Assembly, Pneumatic / Servo GeneralBlades Opt Equipment Parts List To Order Parts Call Toll Free 800 Servo Opt. / Table TravelElectrical Control, 3hp 230/460v Volt