Conair CTS 9, CTS 7, CTS 5 manual Checking the Encoder, Check all connections

Page 54

CHECKING THE ENCODER

When the encoder is working properly, the encoder LEDs on the control panel light or flicker as the encoder wheel moves and generates signals. If the LEDs do not light when the encoder wheel moves:

1

Check all connections.

 

 

2

Check the encoder cable for damage. If neces-

 

sary, replace.

 

 

3

Check the connector that attaches the cable to

 

the encoder. Internal wiring may be shorted out if this

 

connector is not handled properly.

 

 

4

Check the encoder itself. There should be no play

 

in the shaft.

WARNING: Delicate equipment

The encoder is a delicate piece of equipment. Any rough handling can damage fragile parts.

5 If all else fails, contact Conair Customer Service. See Appendix page A-1.

6-8TROUBLESHOOTING

CTS Saw

UGE058/0803

Image 54
Contents Traveling Saw Date Document Number Table of Contents Troubleshooting Introduction Purpose User Guide HOW the User Guide is OrganizedYour Responsibility AS a User Read this SO no ONE Gets Hurt Read this SO no ONE Gets Hurt HOW to USE Lockout Device Turn the rotary disconnect switch to OFF or O positionPage Description What is Typical ApplicationsHOW the CTS SAW Works SAW Works Features CTS SAWSpecifications Optional Equipment Left to right machine operationPage Installation Unpacking the Boxes Carefully uncrate the saw and its componentsPreparing for Installation You need these tools for installationPositioning the CTS SAW Move the saw into position. Place the saw in posiDetermine the best distance from the belt puller to Position the SAW Connecting Main Power Source Installing the Encoder Installing the SAW Blades Remove the hex nutPreparing for Testing Testing the InstallationPage Operation SAW Control Control Features Blade Height Adjustment Machine Frame Support SystemTo remove and/or adjust each clamp assembly Upper Clamp AdjustmentPower Supply Control PanelsPneumatic Cylinder Operation Electrical Operation Machine Lubrication System InspectionBlade Replacement Wait at least five minutes for the blade to stop completelyChip Collection Shrouds Blower Connection Maintenance Maintenance Features Maintenance Checking saw blades Maintenance OverviewPreventative Maintenance Schedule Inspecting the blade mounting hardwareWeekly Checking Blades Checking Electrical Connections Open the electrical enclosure Close the electrical enclosure doorTroubleshooting Before Beginning FEW Words of CautionIdentifying Cause of a Problem Electrical Problems Symptom Possible cause SolutionIncorrect cooling Product Quality ProblemsIncorrect blade design ExtrudateRodless cylinder problem Problem Puller problemCounter problem Solenoid problemChecking Servo Amplifier Check the encoder cable for damage. If neces Checking the EncoderCheck all connections Check the encoder itself. There should be no playWE’RE Here to Help From outside the United States, callAppendix A-2 Conair Servo Traveling Saw Soft KeysNumeric keys Fixed Function Keys at BottomLCD Screen Contents Power Up Sequence Starting CommsMain Screen Length CounterOn/Off Softkey Total Screen Reset SoftkeyTotal Softkey Exit SoftkeyLength Softkey Enter or Delete?Homing Home SeekHome Already Menu Area Maint. SoftkeyMaint. Area R c t n S o f t k e yChange Softkey S o f t k e y Time SoftkeyCycles Softkey B l e S o f t k e yT u r n S o f t k e y Acceptable range is 120.00-1800.00 ipmV a n c e S o f t k e y 20%Error Message Menu Area Factory SoftkeyTable Assembly, Pneumatic / Servo GeneralBlades Opt Equipment Parts List To Order Parts Call Toll Free 800 Servo Opt. / Table TravelElectrical Control, 3hp 230/460v Volt