Conair CTS 9 HOW to USE Lockout Device, Turn the rotary disconnect switch to OFF or O position

Page 9

WARNING: Electrical hazard

Before performing maintenance or repairs on this product, disconnect and lock out electrical power sources to prevent injury from unexpect- ed energization or start-up. A lockable device has been provided to isolate this product from potentially hazardous electricity.

Lockout is the preferred method of isolating machines or equipment from energy sources. Your Conair product is equipped with the lockout device pictured below. To use the lockout device:

1 Stop or turn off the equipment.

2

Isolate the equipment from

 

 

electrical power.

 

 

Turn the rotary disconnect switch to

O

 

OFF or O position.

 

3

Secure the device with an

 

 

assigned lock or tag.

 

4 The equipment is now locked out.

HOW TO USE

THE LOCKOUT

DEVICE

CAUTION: Moving parts

Before removing lockout devices and returning switches to the ON position, make sure that all personnel are clear of the machine, tools have been removed and all safety guards are rein- stalled.

UGE058/0803

CTS Saw

INTRODUCTION 1-5

Image 9
Contents Traveling Saw Date Document Number Table of Contents Troubleshooting Introduction Purpose User Guide HOW the User Guide is OrganizedYour Responsibility AS a User Read this SO no ONE Gets Hurt Read this SO no ONE Gets Hurt Turn the rotary disconnect switch to OFF or O position HOW to USE Lockout DevicePage Description Typical Applications What isHOW the CTS SAW Works SAW Works CTS SAW FeaturesSpecifications Left to right machine operation Optional EquipmentPage Installation Carefully uncrate the saw and its components Unpacking the BoxesYou need these tools for installation Preparing for InstallationPositioning the CTS SAW Move the saw into position. Place the saw in posiDetermine the best distance from the belt puller to Position the SAW Connecting Main Power Source Installing the Encoder Remove the hex nut Installing the SAW BladesTesting the Installation Preparing for TestingPage Operation SAW Control Control Features Machine Frame Support System Blade Height AdjustmentPower Supply Upper Clamp AdjustmentTo remove and/or adjust each clamp assembly Control PanelsPneumatic Cylinder Operation Electrical Operation System Inspection Machine LubricationWait at least five minutes for the blade to stop completely Blade ReplacementChip Collection Shrouds Blower Connection Maintenance Maintenance Features Maintenance Preventative Maintenance Schedule Maintenance OverviewChecking saw blades Inspecting the blade mounting hardwareWeekly Checking Blades Checking Electrical Connections Close the electrical enclosure door Open the electrical enclosureTroubleshooting FEW Words of Caution Before BeginningIdentifying Cause of a Problem Symptom Possible cause Solution Electrical ProblemsIncorrect blade design Product Quality ProblemsIncorrect cooling ExtrudateCounter problem Problem Puller problemRodless cylinder problem Solenoid problemChecking Servo Amplifier Check all connections Checking the EncoderCheck the encoder cable for damage. If neces Check the encoder itself. There should be no playFrom outside the United States, call WE’RE Here to HelpAppendix A-2 Soft Keys Conair Servo Traveling SawNumeric keys Fixed Function Keys at BottomLCD Screen Contents Starting Comms Power Up SequenceMain Screen Length CounterOn/Off Softkey Total Softkey Reset SoftkeyTotal Screen Exit SoftkeyEnter or Delete? Length SoftkeyHome Seek HomingHome Already Maint. Softkey Menu AreaMaint. Area R c t n S o f t k e yChange Softkey Time Softkey S o f t k e yB l e S o f t k e y Cycles SoftkeyAcceptable range is 120.00-1800.00 ipm T u r n S o f t k e y20% V a n c e S o f t k e yMenu Area Factory Softkey Error MessageTable Assembly, Pneumatic / Servo GeneralBlades Opt Servo Opt. / Table Travel Equipment Parts List To Order Parts Call Toll Free 800Volt Electrical Control, 3hp 230/460v