Conair CTS 5, CTS 9, CTS 7 manual Total Softkey, Total Screen, Reset Softkey, Exit Softkey

Page 62

Conair Servo Traveling Saw

Operator Control Instructions

Total Softkey

By pressing the soft key located under the word Total on the Main Screen, a six-decade total counter is available.

TOTAL 000,000 pcs .

Off Exit Reset

Total Screen

This is typically used to count cut pieces during the day or days that the product is being produced.

Sample or aborted cuts are not counted. It is also possible to turn this counter off or on.

Reset Softkey

Under the counter, on the right is a soft key labeled Reset. Pressing this key will zero the counter.

Exit Softkey

Under the counter, in the center is a soft key labeled Exit. Pressing this key will return the display to the Main screen.

On/Off Softkey

Under the counter on the left is a soft key labeled On or Off. Pressing this key while On is displayed will disable the counter. Likewise pressing this key while Off is displayed enables the counter.

EXIT or PREV, fixed function keys return the display to the Main screen.

Appendix B-1 (6)

Image 62
Contents Traveling Saw Date Document Number Table of Contents Troubleshooting Introduction Your Responsibility AS a User Purpose User GuideHOW the User Guide is Organized Read this SO no ONE Gets Hurt Read this SO no ONE Gets Hurt HOW to USE Lockout Device Turn the rotary disconnect switch to OFF or O positionPage Description What is Typical ApplicationsHOW the CTS SAW Works SAW Works Features CTS SAWSpecifications Optional Equipment Left to right machine operationPage Installation Unpacking the Boxes Carefully uncrate the saw and its componentsPreparing for Installation You need these tools for installationDetermine the best distance from the belt puller to Positioning the CTS SAWMove the saw into position. Place the saw in posi Position the SAW Connecting Main Power Source Installing the Encoder Installing the SAW Blades Remove the hex nutPreparing for Testing Testing the InstallationPage Operation SAW Control Control Features Blade Height Adjustment Machine Frame Support SystemTo remove and/or adjust each clamp assembly Upper Clamp AdjustmentPower Supply Control PanelsPneumatic Cylinder Operation Electrical Operation Machine Lubrication System InspectionBlade Replacement Wait at least five minutes for the blade to stop completelyChip Collection Shrouds Blower Connection Maintenance Maintenance Features Maintenance Checking saw blades Maintenance OverviewPreventative Maintenance Schedule Inspecting the blade mounting hardwareWeekly Checking Blades Checking Electrical Connections Open the electrical enclosure Close the electrical enclosure doorTroubleshooting Before Beginning FEW Words of CautionIdentifying Cause of a Problem Electrical Problems Symptom Possible cause SolutionIncorrect cooling Product Quality ProblemsIncorrect blade design ExtrudateRodless cylinder problem Problem Puller problemCounter problem Solenoid problemChecking Servo Amplifier Check the encoder cable for damage. If neces Checking the EncoderCheck all connections Check the encoder itself. There should be no playWE’RE Here to Help From outside the United States, callAppendix A-2 Conair Servo Traveling Saw Soft KeysLCD Screen Numeric keysFixed Function Keys at Bottom Contents Power Up Sequence Starting CommsOn/Off Softkey Main ScreenLength Counter Total Screen Reset SoftkeyTotal Softkey Exit SoftkeyLength Softkey Enter or Delete?Homing Home SeekHome Already Menu Area Maint. SoftkeyChange Softkey Maint. AreaR c t n S o f t k e y S o f t k e y Time SoftkeyCycles Softkey B l e S o f t k e yT u r n S o f t k e y Acceptable range is 120.00-1800.00 ipmV a n c e S o f t k e y 20%Error Message Menu Area Factory SoftkeyBlades Opt Table Assembly, Pneumatic / ServoGeneral Equipment Parts List To Order Parts Call Toll Free 800 Servo Opt. / Table TravelElectrical Control, 3hp 230/460v Volt