Back Up Power Supply

OmniSwitch 6600 Series Chassis and Hardware Components

 

 

 

 

Back Up Power Supply

OmniSwitch 6600 series switches provide one factory-installed power supply per chassis. Each switch also provides one bay for the optional OS66BPS-100A back up power supply. The back up power supply bay is located on the chassis rear panel (see page 2-12for details).

For information on installing a back up power supply, refer to page 2-20. For information on removing a back up power supply, refer to page 2-22.

Product, Safety, and Compliance Information. Refer to the “Regulatory Compliance and Safety Information” chapter for detailed information.

Power Connector Socket.

Type IEC-320-C13. Supports one 10 amp power cord.

It is recommended that you use Alcatel-provided power cords.

CAUTION: THIS UNIT MAY BE EQUIPPED

WITH TWO POWER CONNECTIONS. TO REDUCE

THE RISK OF ELECTRICAL SHOCK, DISCONNECT

BOTH POWER CONNECTIONS BEFORE

!SERVICING UNIT.

ATTENTION: CET APPAREIL COMPORTE PLUS D'UN CORDON D'ALIMENTATION. AFIN DE PREVENIR LES CHOCS ELECTRIQUES, DEBRANCHE LES DEUX CORDONS D'ALIMENTATION AVANTE DE FAIRE LA REPARATION.

100/115/230 V 50/60 Hz, 2/2/1 A

Power Switch. indicates on position; indicates off position.

Back Up Power Supply Front Panel

Power Supply Redundancy

After a back up power supply is installed, the primary (factory-installed) power supply continues to take on the full power load for switch operations. Meanwhile, the back up power supply operates in active standby mode. If the primary power supply fails unexpectedly, the back up power supply automatically takes up the full power load without disrupting the switch.

Back Up Power Supply Specifications

Input Voltage

85 to 250 VAC

 

 

Input Frequency

47 to 63 Hz

 

 

Efficiency

75% measured at 115 VAC

 

 

Temperature

Operating: 0 to +50 Celsius

 

Non-Operating: - 40 to +85 Celsius

 

 

Relative Humidity

5% to 95% non -condensing

 

 

Altitude

10,000 feet @ +32 Celsius

 

 

page 2-18

OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 38
Image 38
Alcatel-Lucent 6600 Series, 6648, 6624 manual Power Supply Redundancy, Back Up Power Supply Front Panel