Temperature Management

The operating temperature of your switch is an important factor in its overall health. In order to avoid a temperature-related system failure, your switch must always run at an operating temperature between 0 and 45 degrees Celsius (32 to 113 degrees Fahrenheit).

To avoid chassis over-temperature conditions, follow these important guidelines:

1Be sure that your switch is installed in a well-ventilated environment. To ensure adequate airflow, leave at least two inches of clearance at the left and right sides.

2If your switch chassis is not fully populated with uplink or stacking modules, be sure that blank cover panels are installed at empty slot positions at all times. Blank cover panels help regulate airflow and thus regulate the overall operating temperature in the switch. Refer to page 2-48for more information.

Viewing Chassis Temperature Status

As with power supply status, the switch constantly monitors the chassis temperature. If a temperature error has occurred, the switch sends out a trap to the user and the TEMP LED on the chassis front panel displays amber.

Note. For detailed LED information, including the TEMP LED, refer to “Status LEDs” on page 2-11.

To check the current chassis temperature status, use the show temperature command. For example:

-> show temperature

 

 

 

 

Temperature for chassis 1

= 39,

 

Hardware Board Temperature (deg C)

 

Hardware Cpu Temperature (deg C)

= N/A,

Temperature Upper

Threshold Range (deg C) =

30

to 77,

Temperature Upper

Threshold (deg C)

=

57,

 

Temperature Range

 

=

UNDER THRESHOLD,

Temperature Danger Threshold (deg C)

=

77

 

In the example above, the switch’s current temperature is 39 degrees Celsius. The switch is operating under the upper temperature threshold, which is 57 degrees Celsius.