Viewing Temperature Status for Stacked Configurations

OmniSwitch 6600 Series Chassis and Hardware Components

Temperature Management

 

 

 

 

Viewing Temperature Status for Stacked Configurations

When entering the show temperature command on the primary switch in a stacked configuration, you can either enter only the show temperature syntax or you can specify a specific slot number. For more information, refer to the examples below:

A Slot Number is Specified

If you specify a slot number after the command syntax, chassis temperature information for only the corre- sponding switch displays. For example:

-> show temperature

3

 

 

 

Temperature for chassis 3

=

43,

 

Hardware Board Temperature (deg C)

 

Hardware Cpu Temperature (deg C)

=

N/A,

Temperature Upper

Threshold Range (deg C) =

30

to 77,

Temperature Upper

Threshold (deg C)

=

57,

 

Temperature Range

 

=

UNDER THRESHOLD,

Temperature Danger Threshold (deg C)

=

77

 

The example above shows chassis temperature information for the switch operating in slot position 3 only. The current temperature is 43 degrees Celsius. The switch is operating under the upper temperature thresh- old.

No Slot Number is Specified

If you do not enter a slot number, fan status information for all switches in the stack displays. For example:

-> show temperature

 

 

 

 

Temperature for chassis 1

=

40,

 

Hardware Board Temperature (deg C)

 

Hardware Cpu Temperature (deg C)

=

N/A,

Temperature Upper

Threshold Range (deg C) =

30

to 77,

Temperature Upper

Threshold (deg C)

=

57,

 

Temperature Range

 

=

UNDER THRESHOLD,

Temperature Danger Threshold (deg C)

=

77

 

Temperature for chassis 2

=

31,

 

Hardware Board Temperature (deg C)

 

Hardware Cpu Temperature (deg C)

=

N/A,

Temperature Upper

Threshold Range (deg C) =

30

to 77,

Temperature Upper

Threshold (deg C)

=

57,

 

Temperature Range

 

=

UNDER THRESHOLD,

Temperature Danger Threshold (deg C)

=

77

 

The example above shows chassis temperature information for a stack consisting of two switches. The current temperature of the switch operating in slot position 1 is 40 degrees Celsius; the current tempera- ture of the switch operating in slot 2 is 31 degrees Celsius. Both switches are operating under the upper temperature threshold.

More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”

OmniSwitch 6600 Series Hardware Users Guide April 2004

page 2-43