Back Up Power SupplyOmniSwitch 6600 Series Chassis and Hardware Components
Viewing Power Supply Status for Stacked Configurations
When entering the show power command on the primary switch in a stacked configuration, you can either enter only the show power syntax or you can specify a specific slot number. For more information, refer to the examples below:
A Slot Number is Specified
If you specify a slot number after the command syntax, power supply information for only the correspond- ing switch displays. For example:
Power Supplies in chassis 2
PS | Operational Status |
NOT PRESENT |
In the example above, power supply status for the switch operating in slot 2 displays. No back up power supply is installed in the slot 2 chassis (or the back up power supply is powered off).
No Slot Number is Specified
If you do not enter a slot number, power supply information for all switches in the stack displays. For example:
Power Supplies in chassis 1
PS | Operational Status |
UP |
Power | Supplies in | chassis 2 |
PS | Operational Status | |
NOT PRESENT |
The example above shows the power supply status for a stack consisting of two switches. A back up power supply is present and running in the switch operating in slot 1; no back up power supply is installed in the switch operating in slot 2 (or the unit is powered off).
More Information on Stacked Configurations. For detailed information on stacked OmniSwitch 6600 series switches, refer to Chapter 3, “Managing OmniSwitch 6600 Series Stacks.”
page | OmniSwitch 6600 Series Hardware Users Guide April 2004 |