Changing the Secondary CMM Role to Primary

Managing Switches in a StackManaging OmniSwitch 6600 Series Stacks

Changing the Secondary CMM Role to Primary

To change a switch with a secondary role to primary use the takeover command. For example, while logged into either the primary or secondary switch enter:

-> takeover

at the CLI prompt. In a stack consisting of two switches the primary switch will become secondary. In a stack consisting of three or more switches the secondary switch will become primary, the idle switch with lowest slot number will become secondary, and the switch that was primary will become idle.

You can determine the current CMM role of a switch by examining the PRI and SEC LEDs on the switch’s front panel. Refer to Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” for more information. You can also use the show running-directorycommand to display whether the switch into which you are currently logged is primary or secondary. For example:

-> show

running-directory

: PRIMARY,

Running

CMM

Running

configuration

: CERTIFIED,

Certify/Restore Status

: CERTIFY NEEDED,

Synchronization Status

: SYNCHRONIZED,

Stacks Reload on Takeover: PRIMARY ONLY

In this example, the user is currently logged in to the switch with the primary CMM role.

Note. Before using the takeover command, verify that the switches in the stack are synchronized. Other- wise, data flow and switch management functions may be interrupted due to incorrect or outdated soft- ware when a switch takes over the primary CMM role. For more information, refer to “Synchronizing Switches in a Stack” on page 3-17.

Module Behavior During Takeover

If there are no unsaved configuration changes and the flash directories on both the primary and secondary management modules have been synchronized via the copy flash-synchrocommand, no modules will be reloaded if a management module takeover occurs. As a result, data flow is not interrupted on the modules during the takeover.

If a configuration change is made to one or more modules (e.g., a VLAN is configured on several differ- ent interfaces), and the changes are not saved via the write memory command, the corresponding modules will automatically reload if a management module takeover occurs. Data flow on the affected modules will be interrupted until the reload is complete. Note that the modules will reload whether or not the flash synchronization status shows SYNCHRONIZED. This is because the unsaved changes have occurred in the running configuration (i.e., RAM), and have not been written to the flash directory’s configuration file. In this case, a list of only the affected modules displays in the table output (e.g., 1 6 9 12).

If the flash directories on the primary and secondary management modules are not synchronized (e.g., a copy flash-synchrocommand has not been issued recently), all modules will be reloaded automatically if a management module takeover occurs. Data flow will be interrupted on all modules until the reload is complete.

page 3-18

OmniSwitch 6600 Series Hardware Users Guide April 2004