Manuals
/
Alcatel-Lucent
/
Computer Equipment
/
Switch
Alcatel-Lucent
6600 Series manual OmniSwitch 6624/6648 Hardware Users Guide
Models:
6600 Series
6624
6648
1
1
114
114
Download
114 pages
33.13 Kb
1
2
3
4
5
6
7
8
<
>
Specs
Install
IEEE 802.3u, IAB RFCs 826, 894 see data sheet for more information
OmniSwitch 6624/6648 Network Configuration Guide
Continue to “Connecting Cables to Stacking Ports” on page
Resetting All Switches in a Stack
CLI Commands Supported
Temperature Errors
Signals as DCE Console Port
Lithium Battery Warning
Page 1
Image 1
Part No.
060181-10,
Rev. C
April 2004
OmniSwitch 6624/6648
Hardware Users Guide
Page 2
Page 1
Image 1
Page 2
Contents
Part No. 060181-10, Rev. C April
OmniSwitch 6624/6648 Hardware Users Guide
Internet-http//eservice.ind.alcatel.com
This user guide documents OmniSwitch 6600 Series hardware, including
chassis and associated components
26801 West Agoura Road Calabasas, CA
Contents
Contents
Chassis Airflow
Appendix A
Supported Platforms
About This Guide
Unsupported Platforms
What is in this Manual?
When Should I Read this Manual?
What is Not in this Manual?
Who Should Read this Manual?
Stage 2 Gaining Familiarity with Basic Switch Functions
Stage 1 Using the Switch for the First Time
Pertinent Documentation OmniSwitch 6600 Series Getting Started Guide
Pertinent Documentation OmniSwitch 6600 Series Hardware Users Guide
Anytime
Stage 3 Integrating the Switch Into a Network
OmniSwitch 6600 Series Hardware Users Guide
OmniSwitch 6600 Series Getting Started Guide
OmniSwitch CLI Reference Guide
OmniSwitch 6624/6648 Network Configuration Guide
Technical Support
User Manual CD
OmniSwitch 6624/6648 Hardware Users Guide April
1 OmniSwitch 6600 Series
Stacked Configurations
Stand-Alone and Stacked Configurations
Stand-Alone
Smart Continuous Switching
Availability Features
Smart Continuous Switching Software Rollback Hot Swapping
Hardware Monitoring
Hot Swapping
Software Rollback
Hardware Monitoring
Automatic Monitoring
Port and Fabric Capacities
OmniSwitch 6600 Series Fabric Capacities
User-Driven Monitoring
OS6624/6600-U24 Throughput
Single Office Building with 1000 Users
Application Examples
OmniPCX
Medium Campus with 1500 Users
OmniSwitch 6600 Series
OmniSwitch 6624/6648 Hardware Users Guide April
Application Examples
page
2 OmniSwitch 6600 Series Chassis and Hardware Components
OmniSwitch 6600-U24
OmniSwitch 6600 Series Chassis and Hardware Components
OmniSwitch
OmniSwitch
OmniSwitch 6624 Front Panel
OmniSwitch
10/100 Ethernet Port Specifications
OS6624 Specifications
OmniSwitch 6600-U24
Console Port
OmniSwitch 6600-U24 Front Panel
Gigabit Ethernet Uplink Module Slot
Slot Selector Button
OS6600-U24 Specifications
IEEE 802.3u, IAB RFCs 826, 894 see data sheet for more information
100 Mbps Ethernet SFP Port Specifications
OmniSwitch
OmniSwitch 6648 Front Panel
TM OmniSwitch
10/100 Ethernet Port Specifications
OS6648 Specifications
Front Panel LED Descriptions OS6648 Shown
Status LEDs
Rear Panel
OmniSwitch 6600 Series Rear Panel
Power Switch indicates on position indicates off position
Redundant Power Supply Bay
OmniSwitch 6600 Series Chassis Top View
Mounting the Switch
Airflow Considerations
Installing the Switch on a Tabletop or Bench
Installation Options
Rack-Mounting the Switch
Attaching a Rack-Mount Flange
Attaching the Switch to the Rack
Rack Mounting Stacked Configurations
Specifications
Power Cords
Power Cord Types
Grounding the Chassis
Power Supply Redundancy
Back Up Power Supply
Back Up Power Supply Front Panel
Back Up Power Supply Specifications
Redundant AC Circuit Recommendation
OmniSwitch 6600 Series Redundant AC Circuit Example
Orienting the Back Up Power Supply
Installing a Back Up Power Supply
Hot Swapping
Tightening the Captive Screws
Inserting the Back Up Power Supply
CAUTIONW F CO
NTIONC CH
Removing the Back Up Power Supply
Removing a Back Up Power Supply
Loosening the Captive Screws
Blank Cover Panel Requirement
Viewing Primary and Back Up Power Supply Status
show power Power Supplies in chassis
Operational Status
A Slot Number is Specified
Viewing Power Supply Status for Stacked Configurations
No Slot Number is Specified
OS6600-GNI-U2
Gigabit Ethernet Uplink Modules
OS6600-GNI-U2 Gigabit Ethernet Uplink Front Panel
OS6600-GNI-U2 Uplink Module Specifications
OS6600-GNI-C2
OS6600-GNI-C2 Uplink Module Specifications
OS6600-GNI-C2 Gigabit Ethernet Uplink Front Panel
Stacking Module
Stacking Module Specifications
Stacking Module Front Panel
Inserting the Uplink or Stacking Module
Installing Uplink and Stacking Modules
LINK/ACT LINK/ACT
Tightening the Captive Screws
Loosening the Captive Screws
Removing Uplink and Stacking Modules
2 LINK/ACT LINK/ACT
Blank Cover Panel Requirement
Removing the Module
Mini Gigabit Interface Converter MiniGBIC
Mini Gigabit Interface Converters MiniGBICs
MiniGBIC-SX Technical Specifications
MiniGBIC Specifications
MiniGBIC-LX Technical Specifications
MiniGBIC-LH-70 Technical Specifications
Inserting the MiniGBIC OS6648 Shown
Installing MiniGBICs
Removing MiniGBICs
Installed MiniGBIC OS6648 Shown
SFP Module
100 Mbps SFPs OS6600-U24
SFP-100-LC-MM Technical Specifications
100 Mbps SFP Specifications
SFP-100-LC-SM15 Technical Specifications
SFP-100-LC-SM40 Technical Specifications
SFP-100-MTRJ-MM Technical Specifications
Inserting the SFP
Installing SFPs OS6600-U24
Removing SFPs OS6600-U24
Viewing Chassis Temperature Status
Temperature Management
A Slot Number is Specified
Viewing Temperature Status for Stacked Configurations
No Slot Number is Specified
Warning Threshold
Temperature Errors
Danger Threshold
Viewing Fan Status
Viewing Fan Status for Stacked Configurations
A Slot Number is Specified
OmniSwitch 6600 Series Hardware Users Guide April
Temperature Management
No Slot Number is Specified
page
Right Side Air Intake Vent
Chassis Airflow
Left Side Fan Exhaust Vents
Effects of Missing Blank Panels on Chassis Airflow
Blank Cover Panels
Signals as DCE Console Port
RS232 Console Port - Female DB9 Connector Pinout
Pinouts
10/100 Ethernet Port - RJ-45 Pinout
Signals as DCE Console Port
RJ-45 Console Port - Connector Pinout
Pin Number
Modifying the Serial Connection Settings
Serial Connection Default Settings
Console Port
Serial Connection to the Console Port
6 Verify your current changes by entering show at the boot prompt
additional table output not shown
Hardware Information
Viewing Basic Chassis Information
show hardware info show module
show module long and show ni show chassis show cmm
Slot and Component Information
Screen output continued on next page
Detailed Slot and Component Information
Viewing Basic Chassis Information
OmniSwitch 6600 Series Hardware Users Guide April
page
Basic Primary Slot and Component Information
Basic Chassis Information
OmniSwitch 6600 Series MAC Range Specifications
Managing MAC Addresses on the Switch
MAC Range Guidelines
Base Chassis MAC Address in Stacked Configurations
Determining Current MAC Address Allocation on the Switch
Base Chassis MAC Address as Unique Identifier
Viewing the Base Chassis MAC Address
In This Chapter
3 Managing OmniSwitch 6600 Series Stacks
Configuration Steps
Specifications and Default Values
Default Value
Parameter Description
Stack Overview
A Stack Composed of Four OmniSwitch 6648 Switches
Slot Numbers within a Stack
Stacking Resiliency and Redundancy
vlan 10 port default 8/1
vlan 10 port default 2/1
CMM Role Redundancy
CMM Roles in a Stack
on Both the Primary and Secondary Role Switches
CLI Commands Supported
Switch Primary
CMM Commands
Memory Monitoring Commands
Switch Logging and Monitoring Commands
Assigning Slot Numbers
Setting Up a Stacked Configuration
SEL Button Location
6 Continue to “Connecting Cables to Stacking Ports” on page
Slot Numbering Example
Stack of Four Switches with Unique Slot Numbers
Setting Up a Stacked Configuration
OmniSwitch 6600 Series Hardware Users Guide April
Attaching the Stacking Cable to a Stacking Port
Connecting Cables to Stacking Ports
Recommended Redundant Connection Between Switches
Connecting the Switches in the Stack
Stacking Cable Redundancy Example
Redundant Stack Connection
Connection Failure Between Switches 1 and
Switch Switch Switch Switch Switch Switch Switch Switch
Verifying Slot Number Assignments
Booting the Stack
Verifying Primary and Secondary Status for the Stack
PRI LED
Idle Status
Reloading a Switch with a Primary or Secondary CMM Role
Managing Switches in a Stack
Reloading the Switch with the Primary CMM Role
Reloading the Switch with the Secondary CMM Role
Restoring Switch Redundancy
Synchronizing Switches in a Stack
Module Behavior During Takeover
Changing the Secondary CMM Role to Primary
reload all
Resetting All Switches in a Stack
Monitoring Stacks
Managing and Monitoring OmniSwitch 6600 Series Stacks
Monitoring Stack Topology
at the prompt. A screen similar to the following would be display
Managing OmniSwitch 6600 Series Stacks
OmniSwitch 6600 Series Hardware Users Guide April
Monitoring Stacks
page
Declaration of Conformity CE Mark
A Regulatory Compliance and Safety Information
Safety and Environmental Standards
Safety Standards
Standards Compliance
EMC Standards
Canada Class A Statement
FCC Class A, Part
JATE
CISPR22 Class A warning
Class A Warning for Taiwan and Other Chinese Markets
VCCI
Chassis Lifting Warning
Translated Safety Warnings
Blank Panels Warning
Electrical Storm Warning
Invisible Laser Radiation Warning
Installation Warning
Operating Voltage Warning
Lithium Battery Warning
Proper Earthing Requirement Warning
Power Disconnection Warning
Restricted Access Location Warning
Read Important Safety Information Warning
Wrist Strap Warning
Numerics
Index
reload command
reload all command
show chassis command
show cmm command