Alcatel-Lucent 6648, 6624 manual Stacking Resiliency and Redundancy, Slot Numbers within a Stack

Models: 6600 Series 6624 6648

1 114
Download 114 pages 33.13 Kb
Page 84
Image 84
Stacking Resiliency and Redundancy

Stack Overview

Managing OmniSwitch 6600 Series Stacks

 

 

 

 

Stacking Resiliency and Redundancy

The figure on page 3-3shows a sample way to connect switches in a four-switch stack to ensure dual- redundant connections. Except for the bottommost switch in the stack, Port 52 is connected to Port 51 on the switch below it with a 30 centimeter stacking cable. On the bottommost switch Port 52 is connected to Port 51 on the topmost switch in the stack with a 1 meter redundant stacking cable. If a stacking connec- tion goes down data can still flow between all the switches in the stack. In addition, if a switch goes down traffic can still flow between the switches that are still operating.

Note. See “Redundant Stack Connection” on page 3-13for more information.

Slot Numbers within a Stack

By default, the slot number for OmniSwitch 6600 series switches is 8. In a stand-alone configuration you would enter 8 when a Command Line Interface (CLI) command requires a slot number. For example, to create VLAN 10 on port 1 on an OmniSwitch 6600 series with the default slot number you would enter

vlan 10 port default 8/1

In a stack, each switch must have a unique slot number, which is configured by the user. (See “Managing Switches in a Stack” on page 3-16for more information.) This slot number can be any whole number between 1 and 8.

For example, if you have assigned slot number 2 to a switch you would enter

vlan 10 port default 2/1

The slot number for each switch is stored in the root /flash directory in the boot.slot.cfg file. This file must exist on every switch in a stack or the stack will not be able to operate correctly. If you accidently delete this file the switch will revert to the default slot number of 8 and will operate in standby mode. To restore the slot number and rejoin the switch to the stack you must physically change the slot by following the steps described in Chapter 2, “OmniSwitch 6600 Series Chassis and Hardware Components,” and reboot the switch.

Note. In a stack consisting of three or more switches a switch that had a primary or secondary CMM role will rejoin the stack in an idle mode.

page 3-4

OmniSwitch 6600 Series Hardware Users Guide April 2004

Page 84
Image 84
Alcatel-Lucent 6648, 6624 manual Stacking Resiliency and Redundancy, Slot Numbers within a Stack, vlan 10 port default 8/1