Graco 3A1705J important safety instructions Pressurized Aluminum Hazard

Page 5

Warnings

WARNING

PRESSURIZED ALUMINUM HAZARD

Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.

Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents.

Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier for compatibility.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage.

Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.

See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s MSDSs and recommendations.

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.

Do not leave the work area while equipment is energized or under pressure. Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

3A1705J

5

Image 5
Contents Instructions Important Safety Instructions Contents Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Hazard Battery Hazard Isocyanate Conditions Important Two-Component Material InformationMaterial Self-Ignition Moisture Sensitivity of IsocyanatesChanging Materials Foam Resins with 245 fa Blowing AgentsXP2i Series Proportioner Models30i Series Approvals SystemsSystems with Air Compressor AccessoriesRelated Manuals Supplied ManualsTypical Installation, with circulation Typical Installation, without circulation Proportioner Control Panel, Component IdentificationGG Generator, MM Motor Control Module MCM, High Power Temperature Control ModuleGenerator Air Compressor Proportioner Control PanelAdvanced Display Module ADM, Engine Control Module,Call Button Function Out Advanced Display Module ADMRed Random Flashing or Solid Module error exists System Status Indicator B ConditionsUSB Module Status LEDs CL Conditions Module Status LEDs CN ConditionsMenu Bar Power Up ScreenSoft Keys Navigation within ScreensIcons See Errors, page 51 for moreIcons Function Softkeys Icon FunctionMotor Control Module MCM MCM Rotary Switch PositionsIcon Description Function Engine Control ModuleColor Load CenterRelated Component Advanced Display Module ADM, page 19, CN for conditions Temperature Control ModulesLow Power Module Lptcm Cable Connections Hptcm a and B Rotary Switch Settings Adjust Rotary SwitchSetting Zone Lptcm a and B Rotary Switch SettingsSize Component Circuit BreakersMCM See Circuit Breaker Configuration Options,Disable LPTCMs For Booster Heat Auxiliary Wiring Diagram OptionsCircuit Breaker Configuration Options Size Component CB10 90 a 120/240V AlternatorOverview Overview HE VB HE VA Locate Reactor SetupTrailer Setup Guidelines, page 35 for instructions Setup Trailer Setup Guidelines Install Wall optional Top View With Wall Side View With Wall General Equipment Guidelines Connect BatteryAdd Fuel Breathing Air Electrical ConnectionsConnect Feed Pumps Connect Heated Hose Install Fluid Temperature SensorConnect Pressure Relief Lines Pressure Check Hose Connect Whip Hose to Gun Or Gun Fluid ManifoldConnect Remote Display Module GroundingSupply Wet Cups With Throat Seal Liquid TSL Advanced Screen 3- USB, Advanced Display Module ADM OperationSet Password Setup ModeSetup Screens Navigation Diagram Figure Advanced Screen 1 General Advanced Setup ScreensAdvanced Screen 3 USB Advanced Screen 2 UnitsSystem Enable or Disable RecipesRecipes Add RecipeRun Mode Run Screens Navigation Diagram Home System Off Home System With ErrorHome System Active TargetsErrors MaintenanceCycles EventsDiagnostic Recipes TroubleshootingSystem Events Startup Load fluid with feed pumps Check coolant colorOpen the main air shutoff valve Setup ADM. Advanced Display Module ADM Operation, Temporary Manual Hose Temperature Control Follow Startup, Fluid CirculationCirculation Through Reactor Gun Manual Jog ModeCirculation Through Gun Manifold Fusion AP gun is shown SprayingSpray Adjustments Shutdown Pressure Relief Procedure,Pressure Relief Procedure Flushing FlushingProportioner Maintenance MaintenanceEvery 500 Service Hours or 1 Year Engine MaintenanceFuel Tank Flush Inlet Strainer ScreenPump Lubrication System Follow Pressure Relief Procedure,Perform Shutdown, Drain CoolantRefill Proportioner Coolant Loop, LED Component LED ColorRefill Proportioner Coolant Loop Maintenance Coolant Specifications Refill Engine Coolant LoopTroubleshoot Errors ErrorsView Errors Error Codes and Troubleshooting TroubleshootingError Type Name Cause Solution Code Location A1NM MCM AlarmA4CH A4CM MCM AlarmA4DA A4DBA7CH A4NM MCM AlarmA7DA A7DBCacb CacaCach Cacm MCMDE0X MCM Alarm Dadx MCM AlarmF9DX MCM Alarm K8NM MCM AlarmP6AX MCM Alarm P4AX MCM AlarmMBN0 MCM Advi SoryError Type Name Cause Solution Code Position T2BE T2AEDeviation T2DB T2DAT2DH T2DET4CA T4CM MCM AlarmT4CB T4CHT4DH T4NM MCM AlarmT6BE T6AET6DA T6DBT8AE V4CM MCM Alarm V1CM MCM AlarmWbnm MCM Alarm T8DAMCM Alarm Wmce MCM AlarmWscx ADM Advisory Wsux USB AdvisoryUSB Data Follow Download Procedure, page 91, to retrieve log filesUSB Logs Event LogDaily Log System Configuration SettingsSystem Software Log Blackbox Log FileCustom Language File Download ProcedureCreate Custom Language Strings Upload ProcedureInformation Screens Appendix a Engine Control Module Run ScreensRun Screen Layout Information Screen LayoutIcon Description Details Mode IconsInstrumentation Icons Shutdown AlarmsDimensions Dimensions Pallet Mounting Dimensions Proportioners For Foam Performance ChartsProportioners For Coatings PressureFusion Mechanical Purge, Round Pattern Fusion Air Purge, Flat PatternFusion Mechanical Purge, Flat Pattern 30i Models Technical SpecificationsRecommended Air Compressors WeightNoise Fluid InletsXP2i Models 3A1705J 105 For Graco Canada Customers Graco Standard WarrantyGraco Information