Troubleshooting |
|
|
|
| |
|
|
|
|
|
|
Error | Error | Type | Name | Cause | Solution |
Code | Position |
|
|
|
|
T8AE | Heat | ALARM | Temperature Not | Low chemical supply | Recirculate heated chemical |
T8BE | Exchanger |
| Rising Hx A (T8AE) | temperature. | back to drum in cold conditions |
|
| Temperature Not |
| before spraying. Chemical | |
|
|
|
| ||
|
|
|
| below 32°F(0°C) at startup. | |
|
|
| Rising Hx B (T8BE) |
| |
|
|
| System stored below | Ensure ambient temperature is | |
|
|
|
| above | |
|
|
|
| control valve operation. |
|
|
|
|
| Plugged filter in sight glass. | Clean or replace filter. See |
|
|
|
| Indicated by consistent | system repair manual. |
|
|
|
| low A and B temperature |
|
|
|
|
| alarms. |
|
|
|
|
| Coolant debris stuck in | Inspect and clean control valve. |
|
|
|
| valve pilot hole or passages. | Repair or replace if necessary. |
|
|
|
|
| See system repair manual. |
|
|
|
| No coolant flow | Check coolant level. Check for |
|
|
|
|
| coolant flow in sight glass. |
|
|
|
|
| Ensure that the circulation |
|
|
|
|
| pump has 240 VAC. If not, |
|
|
|
|
| replace the circulation pump. |
|
|
|
|
| See system repair manual. |
|
|
|
| (T8AE only) J6 connector on | Reconnect J6 connector on |
|
|
|
| load center “Heat Valves” | load center in centered location. |
|
|
|
| location is not centered. |
|
|
|
|
| Bad valve solenoid coil. | Turn on the manual valve |
|
|
|
|
| switch (MV), on the load center, |
|
|
|
|
| and see if the valve solenoid |
|
|
|
|
| shifts. For coolant valve LED |
|
|
|
|
| identification, see system repair |
|
|
|
|
| manual. If solenoid does not |
|
|
|
|
| shift, replace solenoid coil. See |
|
|
|
|
| system repair manual. |
|
|
|
| Valve solenoid not getting | Verify 12 VDC signal is at the |
|
|
|
| 12 VDC electrical signal. | valve solenoid coil connector. |
|
|
|
|
| All three valves are normally |
|
|
|
|
| closed with power removed. |
|
|
|
|
| See system repair manual |
|
|
|
|
| for valve wiring harness |
|
|
|
|
| identification diagram. |
|
|
|
| Bad load center. | Red, blue, and green LEDs |
|
|
|
|
| should light up on load center |
|
|
|
|
| board. If not, replace load |
|
|
|
|
| center. See system repair |
|
|
|
|
| manual. |
|
|
|
| A and B heat | See System Repair Manual for |
|
|
|
| exchanger RTD cables | correct connection. |
|
|
|
|
| |
|
|
|
| cable. |
|
86 | 3A1705J |