Troubleshooting

 

 

 

 

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Position

 

 

 

 

T8AE

Heat

ALARM

Temperature Not

Low chemical supply

Recirculate heated chemical

T8BE

Exchanger

 

Rising Hx A (T8AE)

temperature.

back to drum in cold conditions

 

 

Temperature Not

 

before spraying. Chemical

 

 

 

 

 

 

 

 

below 32°F(0°C) at startup.

 

 

 

Rising Hx B (T8BE)

 

 

 

 

System stored below

Ensure ambient temperature is

 

 

 

 

20°F(-7°C) causing slow

above 20°F(-7°C).

 

 

 

 

control valve operation.

 

 

 

 

 

Plugged filter in sight glass.

Clean or replace filter. See

 

 

 

 

Indicated by consistent

system repair manual.

 

 

 

 

low A and B temperature

 

 

 

 

 

alarms.

 

 

 

 

 

Coolant debris stuck in

Inspect and clean control valve.

 

 

 

 

valve pilot hole or passages.

Repair or replace if necessary.

 

 

 

 

 

See system repair manual.

 

 

 

 

No coolant flow

Check coolant level. Check for

 

 

 

 

 

coolant flow in sight glass.

 

 

 

 

 

Ensure that the circulation

 

 

 

 

 

pump has 240 VAC. If not,

 

 

 

 

 

replace the circulation pump.

 

 

 

 

 

See system repair manual.

 

 

 

 

(T8AE only) J6 connector on

Reconnect J6 connector on

 

 

 

 

load center “Heat Valves”

load center in centered location.

 

 

 

 

location is not centered.

 

 

 

 

 

Bad valve solenoid coil.

Turn on the manual valve

 

 

 

 

 

switch (MV), on the load center,

 

 

 

 

 

and see if the valve solenoid

 

 

 

 

 

shifts. For coolant valve LED

 

 

 

 

 

identification, see system repair

 

 

 

 

 

manual. If solenoid does not

 

 

 

 

 

shift, replace solenoid coil. See

 

 

 

 

 

system repair manual.

 

 

 

 

Valve solenoid not getting

Verify 12 VDC signal is at the

 

 

 

 

12 VDC electrical signal.

valve solenoid coil connector.

 

 

 

 

 

All three valves are normally

 

 

 

 

 

closed with power removed.

 

 

 

 

 

See system repair manual

 

 

 

 

 

for valve wiring harness

 

 

 

 

 

identification diagram.

 

 

 

 

Bad load center.

Red, blue, and green LEDs

 

 

 

 

 

should light up on load center

 

 

 

 

 

board. If not, replace load

 

 

 

 

 

center. See system repair

 

 

 

 

 

manual.

 

 

 

 

A and B heat

See System Repair Manual for

 

 

 

 

exchanger RTD cables

correct connection.

 

 

 

 

cross-connected to splitter

 

 

 

 

 

cable.

 

86

3A1705J

Image 86
Contents Important Safety Instructions InstructionsContents Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Hazard Battery Hazard Material Self-Ignition Important Two-Component Material InformationIsocyanate Conditions Moisture Sensitivity of IsocyanatesFoam Resins with 245 fa Blowing Agents Changing MaterialsXP2i Series Proportioner Models30i Series Systems ApprovalsAccessories Systems with Air CompressorSupplied Manuals Related ManualsTypical Installation, with circulation Typical Installation, without circulation Proportioner Control Panel, Component IdentificationGG Generator, High Power Temperature Control Module MM Motor Control Module MCM,Generator Advanced Display Module ADM, Proportioner Control PanelAir Compressor Engine Control Module,Advanced Display Module ADM Call Button Function OutUSB Module Status LEDs CL Conditions System Status Indicator B ConditionsRed Random Flashing or Solid Module error exists Module Status LEDs CN ConditionsSoft Keys Power Up ScreenMenu Bar Navigation within ScreensIcons Function See Errors, page 51 for moreIcons Softkeys Icon FunctionMCM Rotary Switch Positions Motor Control Module MCMEngine Control Module Icon Description FunctionColor Load CenterRelated Component Advanced Display Module ADM, page 19, CN for conditions Temperature Control ModulesLow Power Module Lptcm Cable Connections Setting Zone Adjust Rotary SwitchHptcm a and B Rotary Switch Settings Lptcm a and B Rotary Switch SettingsMCM Circuit BreakersSize Component See Circuit Breaker Configuration Options,Circuit Breaker Configuration Options Auxiliary Wiring Diagram OptionsDisable LPTCMs For Booster Heat Size Component CB10 90 a 120/240V AlternatorOverview Overview HE VB HE VA Locate Reactor SetupTrailer Setup Guidelines, page 35 for instructions Setup Trailer Setup Guidelines Install Wall optional Top View With Wall Side View With Wall General Equipment Guidelines Connect BatteryAdd Fuel Breathing Air Electrical ConnectionsConnect Feed Pumps Connect Heated Hose Install Fluid Temperature SensorConnect Pressure Relief Lines Connect Remote Display Module Connect Whip Hose to Gun Or Gun Fluid ManifoldPressure Check Hose GroundingSupply Wet Cups With Throat Seal Liquid TSL Advanced Display Module ADM Operation Advanced Screen 3- USB,Setup Mode Set PasswordSetup Screens Navigation Diagram Figure Advanced Screen 3 USB Advanced Setup ScreensAdvanced Screen 1 General Advanced Screen 2 UnitsRecipes Enable or Disable RecipesSystem Add RecipeRun Mode Run Screens Navigation Diagram Home System Active Home System With ErrorHome System Off TargetsCycles MaintenanceErrors EventsDiagnostic Troubleshooting RecipesSystem Events Startup Load fluid with feed pumps Check coolant colorOpen the main air shutoff valve Setup ADM. Advanced Display Module ADM Operation, Temporary Manual Hose Temperature Control Follow Startup, Fluid CirculationCirculation Through Reactor Gun Manual Jog ModeCirculation Through Gun Manifold Spraying Fusion AP gun is shownSpray Adjustments Pressure Relief Procedure, ShutdownPressure Relief Procedure Flushing FlushingMaintenance Proportioner MaintenanceFuel Tank Engine MaintenanceEvery 500 Service Hours or 1 Year Flush Inlet Strainer ScreenFollow Pressure Relief Procedure, Pump Lubrication SystemRefill Proportioner Coolant Loop, Drain CoolantPerform Shutdown, LED Component LED ColorRefill Proportioner Coolant Loop Maintenance Refill Engine Coolant Loop Coolant SpecificationsTroubleshoot Errors ErrorsView Errors Error Type Name Cause Solution Code Location TroubleshootingError Codes and Troubleshooting A1NM MCM AlarmA4DA A4CM MCM AlarmA4CH A4DBA7DA A4NM MCM AlarmA7CH A7DBCach CacaCacb Cacm MCMF9DX MCM Alarm Dadx MCM AlarmDE0X MCM Alarm K8NM MCM AlarmMBN0 MCM Advi P4AX MCM AlarmP6AX MCM Alarm SoryError Type Name Cause Solution Code Position T2BE T2AEDeviation T2DH T2DAT2DB T2DET4CB T4CM MCM AlarmT4CA T4CHT4NM MCM Alarm T4DHT6DA T6AET6BE T6DBT8AE Wbnm MCM Alarm V1CM MCM AlarmV4CM MCM Alarm T8DAWscx ADM Advisory Wmce MCM AlarmMCM Alarm Wsux USB AdvisoryUSB Logs Follow Download Procedure, page 91, to retrieve log filesUSB Data Event LogSystem Software Log System Configuration SettingsDaily Log Blackbox Log FileDownload Procedure Custom Language FileUpload Procedure Create Custom Language StringsRun Screen Layout Appendix a Engine Control Module Run ScreensInformation Screens Information Screen LayoutIcon Description Details Mode IconsInstrumentation Icons Alarms ShutdownDimensions Dimensions Pallet Mounting Dimensions Proportioners For Coatings Performance ChartsProportioners For Foam PressureFusion Air Purge, Flat Pattern Fusion Mechanical Purge, Round PatternFusion Mechanical Purge, Flat Pattern Technical Specifications 30i ModelsNoise WeightRecommended Air Compressors Fluid InletsXP2i Models 3A1705J 105 For Graco Canada Customers Graco Standard WarrantyGraco Information