Graco 3A1705J important safety instructions T2AE, Deviation, T2BE

Page 81

 

 

 

 

 

Troubleshooting

 

 

 

 

 

 

Error

Error

Type

Name

Cause

Solution

Code

Position

 

 

 

 

T2AE

Heat

DEVIATION

Low Temperature

Recirculating material

Recirculate material

T2BE

Exchanger

 

Hx A

to heat with drum feed

using Jog mode for heat

 

 

Low Temperature

pumps only.

exchanger heating.

 

 

 

 

 

 

Coolant circulation pump

Check for 240 VAC on

 

 

 

Hx B

not working.

pump. If there is the correct

 

 

 

 

 

voltage, replace circulation

 

 

 

 

 

pump. See system repair

 

 

 

 

 

manual.

 

 

 

 

Air lock in circulation

Check for coolant flow in

 

 

 

 

pump.

sight glass.

 

 

 

 

Loose or incorrect wiring

See wiring schematics, in

 

 

 

 

connections.

the system repair manual,

 

 

 

 

 

and verify coolant valve

 

 

 

 

 

connections. Check coolant

 

 

 

 

 

valve harness and verify

 

 

 

 

 

voltage is 11–13 volts at

 

 

 

 

 

coolant valve connectors.

 

 

 

 

No voltage to coil of

Turn on the manual valve

 

 

 

 

valve.

switch (MV), on the load

 

 

 

 

 

center (PE), to manually turn

 

 

 

 

 

on the solenoids and see if

 

 

 

 

 

the temperature rises. If not,

 

 

 

 

 

check voltage output on J6

 

 

 

 

 

connector on the load center

 

 

 

 

 

and ensure the LEDS are

 

 

 

 

 

on. See load center wiring

 

 

 

 

 

in system repair manual.

 

 

 

 

 

Follow Load Center

 

 

 

 

 

Diagnostics instructions

 

 

 

 

 

in system repair manual. If

 

 

 

 

 

necessary, replace the load

 

 

 

 

 

center board.

 

 

 

 

 

If voltage is present,

 

 

 

 

 

measure the resistance

 

 

 

 

 

of the coil, it should be

 

 

 

 

 

approximately 12.5 Ω, if coil

 

 

 

 

 

is open replace coil.

 

 

 

 

 

If voltage is present, test

 

 

 

 

 

the coil with screwdriver.

 

 

 

 

 

The screwdriver should

 

 

 

 

 

magnetically stick inside

 

 

 

 

 

the coil. If screwdriver

 

 

 

 

 

sticks, then the coil is

 

 

 

 

 

good. Replace the plunger

 

 

 

 

 

on valve or replace the

 

 

 

 

 

complete valve assembly.

 

 

 

 

 

See system repair manual.

3A1705J

81

Image 81
Contents Instructions Important Safety InstructionsContents Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Hazard Battery Hazard Isocyanate Conditions Important Two-Component Material InformationMaterial Self-Ignition Moisture Sensitivity of IsocyanatesChanging Materials Foam Resins with 245 fa Blowing AgentsProportioner Models 30i SeriesXP2i Series Approvals SystemsSystems with Air Compressor AccessoriesRelated Manuals Supplied ManualsTypical Installation, with circulation Typical Installation, without circulation Component Identification GG Generator,Proportioner Control Panel, MM Motor Control Module MCM, High Power Temperature Control ModuleGenerator Air Compressor Proportioner Control PanelAdvanced Display Module ADM, Engine Control Module,Call Button Function Out Advanced Display Module ADMRed Random Flashing or Solid Module error exists System Status Indicator B ConditionsUSB Module Status LEDs CL Conditions Module Status LEDs CN ConditionsMenu Bar Power Up ScreenSoft Keys Navigation within ScreensIcons See Errors, page 51 for moreIcons Function Softkeys Icon FunctionMotor Control Module MCM MCM Rotary Switch PositionsIcon Description Function Engine Control ModuleLoad Center Related ComponentColor Temperature Control Modules Low Power Module Lptcm Cable ConnectionsAdvanced Display Module ADM, page 19, CN for conditions Hptcm a and B Rotary Switch Settings Adjust Rotary SwitchSetting Zone Lptcm a and B Rotary Switch SettingsSize Component Circuit BreakersMCM See Circuit Breaker Configuration Options,Disable LPTCMs For Booster Heat Auxiliary Wiring Diagram OptionsCircuit Breaker Configuration Options Size Component CB10 90 a 120/240V AlternatorOverview Overview HE VB HE VA Setup Trailer Setup Guidelines, page 35 for instructionsLocate Reactor Setup Trailer Setup Guidelines Install Wall optional Top View With Wall Side View With Wall Connect Battery Add FuelGeneral Equipment Guidelines Electrical Connections Connect Feed PumpsBreathing Air Install Fluid Temperature Sensor Connect Pressure Relief LinesConnect Heated Hose Pressure Check Hose Connect Whip Hose to Gun Or Gun Fluid ManifoldConnect Remote Display Module GroundingSupply Wet Cups With Throat Seal Liquid TSL Advanced Screen 3- USB, Advanced Display Module ADM OperationSet Password Setup ModeSetup Screens Navigation Diagram Figure Advanced Screen 1 General Advanced Setup ScreensAdvanced Screen 3 USB Advanced Screen 2 UnitsSystem Enable or Disable RecipesRecipes Add RecipeRun Mode Run Screens Navigation Diagram Home System Off Home System With ErrorHome System Active TargetsErrors MaintenanceCycles EventsDiagnostic Recipes TroubleshootingSystem Events Startup Check coolant color Open the main air shutoff valveLoad fluid with feed pumps Setup ADM. Advanced Display Module ADM Operation, Temporary Manual Hose Temperature Control Fluid Circulation Circulation Through ReactorFollow Startup, Jog Mode Circulation Through Gun ManifoldGun Manual Fusion AP gun is shown SprayingSpray Adjustments Shutdown Pressure Relief Procedure,Pressure Relief Procedure Flushing FlushingProportioner Maintenance MaintenanceEvery 500 Service Hours or 1 Year Engine MaintenanceFuel Tank Flush Inlet Strainer ScreenPump Lubrication System Follow Pressure Relief Procedure,Perform Shutdown, Drain CoolantRefill Proportioner Coolant Loop, LED Component LED ColorRefill Proportioner Coolant Loop Maintenance Coolant Specifications Refill Engine Coolant LoopErrors View ErrorsTroubleshoot Errors Error Codes and Troubleshooting TroubleshootingError Type Name Cause Solution Code Location A1NM MCM AlarmA4CH A4CM MCM AlarmA4DA A4DBA7CH A4NM MCM AlarmA7DA A7DBCacb CacaCach Cacm MCM DE0X MCM Alarm Dadx MCM Alarm F9DX MCM Alarm K8NM MCM AlarmP6AX MCM Alarm P4AX MCM AlarmMBN0 MCM Advi SoryError Type Name Cause Solution Code Position T2AE DeviationT2BE T2DB T2DAT2DH T2DET4CA T4CM MCM AlarmT4CB T4CHT4DH T4NM MCM AlarmT6BE T6AET6DA T6DBT8AE V4CM MCM Alarm V1CM MCM AlarmWbnm MCM Alarm T8DAMCM Alarm Wmce MCM AlarmWscx ADM Advisory Wsux USB AdvisoryUSB Data Follow Download Procedure, page 91, to retrieve log filesUSB Logs Event LogDaily Log System Configuration SettingsSystem Software Log Blackbox Log FileCustom Language File Download ProcedureCreate Custom Language Strings Upload ProcedureInformation Screens Appendix a Engine Control Module Run ScreensRun Screen Layout Information Screen LayoutMode Icons Instrumentation IconsIcon Description Details Shutdown AlarmsDimensions Dimensions Pallet Mounting Dimensions Proportioners For Foam Performance ChartsProportioners For Coatings PressureFusion Mechanical Purge, Round Pattern Fusion Air Purge, Flat PatternFusion Mechanical Purge, Flat Pattern 30i Models Technical SpecificationsRecommended Air Compressors WeightNoise Fluid InletsXP2i Models 3A1705J 105 Graco Standard Warranty Graco InformationFor Graco Canada Customers