Carrier 50BV020-064 specifications

Page 60
Manual background

60

NOTE: Jumper installed for condenser water flow switch when not supplied.

Fig. 43 — 50BVW,X034-064 Variable Air Volume Low Voltage Schematic

Image 60
Contents Installation, Start-Upand Service Instructions CONTENTSSAFETY CONSIDERATIONS MAJOR SYSTEM COMPONENTS Constant Volume CV Units GENERALINSTALLATION Step 1 - Complete Pre-InstallationChecksTable 2 - Modular Unit Shipping Table a50-7257efFig. 2 - 50BVC,J,Q020-034Dimensions Fig. 3 - 50BVE,K020-034Dimensions Fig. 4 - 50BVT,V,W034 High-BoyDimensions a50-8201Fig. 5 - 50BVT,V,W034 Low-BoyDimensions Fig. 6 - 50BVT,V,W044-064 High-BoyDimensions Fig. 7 - 50BVT,V,W044-064 Low-BoyDimensions Fig. 8 - 50BVU,X034 High-BoyDimensions Fig. 9 - 50BVU,X034 Low-BoyDimensions Fig. 10 - 50BVU,X044-064 High-BoyDimensions Fig. 11 - 50BVU,X044-064 Low-BoyDimensions NOTES 1.Dimensions in inches mm a50-7306efNOTES 1.Dimensions in inches mm a50-7307efShipping Weights lb a50-8235Size 034 Units Size 044-064Units Table 3A - Physical Data - 50BVC,E,J,K,Q Table 3B - Physical Data - 50BVT,U,V,W,X Fig. 15 - Typical Fan Discharge Connections for Multiple Fan Unitsa50-7138ef Fig. 16 - Duct Static Pressure ProbeP/N 39EK20462 a50-7267efFig. 19 - DHS Limit Switch P/N Step 4 - Make Piping Connectionsa50-8253 Fig. 18 - DHS Pressure Limit LocationTable 5A - Condenser Pressure Drop 50BVC,J,Q UnitsTable 5B - Condenser Pressure Drop 50BVT,V,W UnitsTable 6A - Hot Water Pressure Drop 50BVC,E,J,K,Q UnitsTable 6B - Hot Water Pressure Drop 50BVT,U,V,W,X UnitsStep 5 - Complete Electrical Connections Table 7B - Economizer Pressure Drop Curveft wg, 50BVT,U,V,W,X Units a50-7270efTable 9A - Electrical Data - 50BVC,E,J,K,Q Table 9B - Electrical Data - 50BVT,U,V,W,X Fig. 24 - Typical Wiring 18 to 30 Ton Units a50-7272efTwo-StageCooling Units a50-7273ef Table 10 - Recommended Cablesa50-7164tf Fig. 26 - Field Terminal BlockInstallation Unit Discharge Location a50-7275efFig. 27 - Modular Unit VAV Control Panel a39-1867tSTART-UP Table 11 - Thermistor Resistance vs TemperatureValues for Supply-AirTemperature Sensor 10 Kilo- ohmCV Unit Start-Up Table 13 - Fan Performance - 50BVC,E,Q020Table 14 - Fan Performance - 50BVC,E,Q024 Table 15 - Fan Performance - 50BVC,E,Q028 Table 16 - Fan Performance - 50BVC,E,Q034 Table 17 - Fan Performance - 50BVT,U,V034 Table 17 - Fan Performance - 50BVT,U,V034 cont Table 18 - Fan Performance - 50BVT,U,V044 Table 19 - Fan Performance - 50BVT,U,V054 Table 19 - Fan Performance - 50BVT,U,V054 cont Table 20 - Fan Performance - 50BVT,U,V064 Table 20 - Fan Performance - 50BVT,U,V064 cont VAV Unit Start-Up OMNIZONE VPAC 02-06-04Fig. 32 - LID a50-7425efFig. 33 - 50BV VFD Display The LID display will show Year Table 21 - Controller Set Points Table 22 - Controller Hardware PointsTable 23 - Software Points Table 24 - Configuration Parameters Unoccupied space or return air temperature demand SERVICE MAINTENANCEa50-186tf Fig. 34 - Gravity Flow Methoda50-187tf Fig. 35 - Forced Circulation MethodEvaporator Fan Performance Adjustment TROUBLESHOOTINGCharging the System a50-7135tfPROBLEM POSSIBLE CAUSETable 28 - Unit Troubleshooting PROBLEMCORRECTION PROCEDURE POSSIBLE CAUSETable 29 - CV Units LED Diagnostic Codes Table 30 - Forcing an Input or OutputTable 31 - Clearing a Forced Input or Output Page Page Page Page FIELD WIRING UNIT WIRINGPage FIELD WIRING WIRE LEGENDa50-7282ef TRANS-1FIELD WIRING PCB2 J1FIELD WIRING UNIT WIRINGPCB1 FIELD WIRING PCB1LEGEND AND NOTES FOR FIG Copyright 2008 Carrier Corporation Catalog NoForm 50BV-3SI 10-08START-UPCHECKLIST I. PRELIMINARY INFORMATIONII. PRE-START-UP CONTROLSIII.START-UP