Section II - Description
Back-up Control
The QSD™ Power$ync II™ controller is supplied with a
!CAUTION
Under no condition should the QSD™ be switched from Power$ync II to
!CAUTION
Always inspect for component failure before operating in
Shutdown Conditions
NOTE
If one of the following conditions occurs at any time the unit will immediately shutdown. The unit should not be restarted until the problem has been corrected.
•The fluid pressure does not reach 15 PSI within five
(5)seconds at
•The HAT’s are open at
•The drive or fan contactor overloads trip.
•The coolant flow switch does not close within five
(5)seconds after
•The interstage pressure switch does not open within five (5) seconds after
•The second stage pressure switch does not open within five (5) seconds after
•Both the interstage and second stage pressure switches are open at
•The second stage pressure switch does not close within five (5) seconds after the load/unload pressure switch opens and does not reopen within five (5) seconds after the load/unload pressure switch closes
!WARNING
High voltage could cause death or serious injury. Disconnect all power supplies before opening the electrical enclosure or servicing.
Quincy Compressor® - QSD™ | 13 |
|
|