| Section IX - Troubleshooting |
|
|
|
|
Probable Causes: | Corrective Action: |
|
|
|
|
Low Air Delivery: |
|
|
|
EXCESSIVE AIR DEMAND | REEVALUATE AIR DEMAND. INSTALL ADDITIONAL COMPRESSORS |
| AS NEEDED. |
EXCESSIVE LEAKS IN THE SERVICE LINES | CHECK SERVICE LINES FOR LEAKS WITH SOAP SUDS. REPAIR AS |
| NECESSARY. |
MINIMUM PRESSURE CHECK VALVE | REPAIR OR REPLACE AS NECESSARY. |
STUCK |
|
LEAKING BLOWDOWN VALVE(S) | CHECK AND REPLACE AS NECESSARY. |
PLUGGED AIR INTAKE FILTER | CLEAN OR REPLACE AIR FILTER ELEMENT. |
INOPERATIVE LIFT VALVE | CONTACT AN AUTHORIZED QUINCY SERVICE TECHNICIAN FOR |
| REPAIRS. |
|
|
|
|
Frequent Air Cleaner Clogging: |
|
|
|
COMPRESSOR OPERATING IN HIGHLY | USE REMOTE AIR INTAKE MOUNTING. |
CONTAMINATED ATMOSPHERE |
|
AIR CLEANER NOT ADEQUATE FOR | USE SPECIALIZED AIR CLEANER. CONTACT AN AUTHORIZED |
CONDITIONS | QUINCY SERVICE TECHNICIAN. |
|
|
|
|
Frequent Fluid Filter Clogging: |
|
|
|
INCORRECT FLUID FILTER | USE GENUINE QUINCY REPLACEMENT FILTERS ONLY. |
SYSTEM CONTAMINATION | CLEAN SYSTEM OF ALL DIRT, CORROSION AND VARNISH. |
|
|
|
|
High Discharge Air Temperature: |
|
|
|
EXCESSIVE AMBIENT TEMPERATURES | MAXIMUM AMBIENT FOR PROPER OPERATION IS LISTED IN DATA |
| SHEET. VENTILATE ROOM OR RELOCATE COMPRESSOR. |
INADEQUATE COOLANT FLOW THROUGH | CLEAN COOLER(S). CHECK WATER SYSTEM FOR POSSIBLE |
COOLER(S) | RESTRICTIONS. |
INADEQUATE CIRCULATION OF COOLING | CHECK THE COOLER TO ASSURE THERE ARE NO RESTRICTIONS TO |
AIR | FREE CIRCULATION OF COOLING AIR. |
| CHECK FINS OF COOLER FOR DIRT |
| CLEAN FINS WITH AIR (WHILE MACHINE IS NOT RUNNING). |
| CHECK FOR HOT AIR RECIRCULATION OR HOT AIR FROM OTHER |
| EQUIPMENT. |