Quinny 65040-AB manual Section Viii Power$ync II Operation, Introduction to Power$ync

Page 34

Section VIII - Power$ync IIOperation

• Introduction to Power$ync II(version 1.04)

Back-up Mode Operation

Single Machine Operational Mode

Multiple Machine Operational Mode

Pressure Settings

Network Installation

Network Voltage Tests on Power$ync II® Systems

Network Setup

Start-up

Power-up Displays

Start-up Displays

Operational Displays

Compressor Settings and Maintenance Displays

Cautionary and Shutdown Displays

Shutdown Log Messages

Introduction to Power$ync II

!WARNING

Always disconnect and follow lockout/tag-out procedures before attempting any repair or adjustment to any electrical component on this compressor.

The Power$ync IIcontrol for the QSD model compressors consists of a two-stage oil-free airend and an associated computerized controller. Together, these features have been designed to provide the best full-load and unloaded efficiencies available in the compressor industry. Besides providing outstanding single machine efficiencies, this control includes multi-machine control.

This control uses four pressure transducers and four RTD temperature probes for the computerized controller. The pressure transducers are located in the control panel. Each transducer is plumbed to its own specific location. Pressure is measured at the discharge of stage one, discharge of stage two, and the discharge of the package. Package discharge is located on the customer side of the package check valve. Fluid pressure is also measured.

The RTD temperature probes are installed at the discharge of each compressor stage, at the inlet of stage two and at the discharge of the package.

There is a coolant flow switch to prevent the unit from running if there is no coolant flow. If the unit is shut down by the coolant flow switch, the control will display ‘Emergency Stop Button Pressed’.

Back-up Mode Operation

The Power$ync IIcontrol on QSDcompressors has a built-in feature not found on other oil-free compressors. In the unlikely event of a failure of any component of the electronic control, the electronic control may be switched off and the machine operated in Back-up Mode until the problem is taken care of.

The Back-up Mode must not be used to bypass a shutdown condition that occurred in Power$ync IIMode. The cause of the shutdown must be found and corrected before operating the compressor any further. The Back-up Mode must not be used for continuous operation.

The Back-up Mode is a separate control circuit using pressure switches, snap disk temperature switches and a PLC. The settings of the pressure switches should be verified before operating in this mode. After disconnecting power, PS1 should be set to open at the unload pressure of the package and is the only adjustable pressure switch. PS2 and PS3 are not adjustable and are factory set to open at 23 psig. PS4 is not adjustable and is factory set to close at 15 psig.

With these settings verified, activate the Back-up Mode as follows:

1)Disconnect power from the compressor.

2)Open the electrical enclosure door, and turn the selector switch to Back-up Mode.

3)Close the electrical enclosure door and reconnect power to the compressor.

4)Wait thirty seconds and press START.

Do not switch modes with power on the compressor!

32

Quincy Compressor® - QSD™

 

 

Image 34
Contents QSD Series Page Table of Contents Section V Maintenance or Service Preparation Standard Warranty Dimensional Data air-cooled Dimensional Data water-cooled Safety Precautions Section I GeneralSafety Alert Symbols Spare Parts Ordering InformationSection II Description General Description Compression Cycle and Air FlowMoisture Separator Cooling SystemLubricating Fluid System Water-cooledCapacity Control System Electrical System Back-up Control Shutdown ConditionsMain Power on Light IndicatorsSafety Sensors High Discharge Air Temperature LightsSection II Description Receiving Section III InstallationMoving the Unit to the Installation Site LocationPiping Connections Manual Shutoff Valve Piping Fit-upElectrical GuardsWater Flow Water QualityFluid Level Fan RotationStarting the Compressor Section IV Operating ProceduresPrior to Starting Stopping the Compressor Normal OperationPressure Readings Temperature Readings Water-cooledStopping the Compressor Emergency Section V Preparing for Maintenance or Service This page Intentionally Left Blank Fluid Specifications SafetySection VI Servicing Air Filter Fluid LifePreparation for New Seal Installation Input Shaft SealSeal Installation Airend Sealing SystemPressure Switch Back-up Operating Mode Section VII Service AdjustmentsPressure Switch Adjusting Pressure SwitchThis page Intentionally Left Blank Back-up Mode Operation Section Viii Power$ync II OperationIntroduction to Power$ync Do not switch modes with power on the compressorSingle Machine Operational Modes Multiple Machine Operational ModeAuto Dual Time Delay Continuous RunPressure Settings Network Load Delay TimeNetwork Installation Connecting Cable to the Power$ync II Circuit BoardRocker Switch Settings Network Setup Network Voltage Tests on Power$ync II SystemsUP/DOWN DEADBAND, F1 EDIT, Enter Return Power-up Displays Start-upSection Viii Power$ync II Operation Compressor in Back-up Mode U19 Memory Failure Contact Your Service RepresentativeU19 Data Checksum Error Press F2 to Update Deadband Data Error Press F1 to ClearU19 Data not Initialized Press F2 to Initialize Filter Needs Servicing Please Replace AS Soon AS Possible Additional Sensors Start-up DisplaysOperational Displays Compressor is StartingCompressor is Unloaded Compressor is Unloaded Minutes Left to ShutdownProgrammed Shutdown Compressor Mode of Operation Auto Dual Timed Stop Press F1 Compressor Settings and Maintenance DisplaysMode and Pressure Displays Press F2Read Pressure Settings pages 34-35 before Press F1 to change the load and unload pressuresPlease Wait Network Configuration in Progress Machine ID SetupMachine ID for this Compressor Press Enter to Accept Value UP/DOWN POSITION, F1 EDIT, Enter Return Before setting or changing a sequence, readSequence Network Data UP/DOWN Machine ID, Enter ReturnDAY Monday SEQ Abcd Network Configuration MenuDAY Monday SEQ To clear a particular sequence from the memory, press F1 Compressor Hourmeter Menu Compressor Hourmeters Filter Service HourmetersReset Service Hourmeters Intake Filter HoursPress F1 to Reset Fluid Hours Press Enter to Return Press F1 to Reset Fluid Filter Hours Press Enter to ReturnFluid Filter Hours Reset to Press Enter to Return Fluid Hours Reset to Press Enter to ReturnTo SET Time and Date Compressor Maintenance Menu Compressor Control TestTime Menu To View Current Time Time and Date Menu Current Time on this ControlUnload Press HorsepowerCompressor Control Test Menu Unload Valve Test Press F1 Fluid PressCompressor Diagnostic Menu View Shutdown LOG Unit Configuration DateModem Baud Rate Setup Network DiagnosticSection Viii Power$ync II Operation ETOL00 FTOL00 Network Connection Data Confidence Modem INITIALIZATION** Init Indicator is lit, the indicator will remain litF1 to EDIT/ENTER to Accept Value Compressor has Shut Down Emergency Stop Button WAS Pressed Sequence Data Error Press F1 to Clear Schedule Data Error Compressor has Shut Down Take Corrective Action Back-up Mode until all faults have been corrected Inlet Temp Fluid Pressure STG 1 OUT Temp STG 2 in Temp Shutdown Log Messages Emergency Stop PressedMotor Overload STG 2 Discharge RTD Failure Control log has no entries at that point Section IX Troubleshooting Probable Causes Corrective Action Failure to StartSection IX Troubleshooting Unscheduled ShutdownProbable Causes Corrective Action Unscheduled Shutdown Probable Causes Corrective Action Low Air Delivery Frequent Air Cleaner CloggingHigh Discharge Air Temperature Frequent Fluid Filter CloggingCompressor does not Unload when there is no Air Demand Too Rapid Cycling Between Load and Unload Water in Buffing Air Vent Bowls Pressure Relief Valve ExhaustingExcessive Fluid in Buffing Air Vent Bowls Excessive Fluid in Gearbox Vent BowlLow Delivery Pressure High Interstage PressureErroneous Displays Microprocessor Will Not Display MessagesSection X- Maintenance Schedule Interval ActionDaily Operating Record Quincy Compressor QSD Quincy Compressor QSD