Section VIII - Power$ync II™ Operation
STG 2 DISCHARGE RTD FAILURE
The stage two discharge RTD is the temperature probe in the stage two discharge piping. The control will log this message if it fails to receive a valid signal from this probe.
STG 2 TRANSDUCER FAILURE
The stage two pressure transducer is the pressure sensor located in the piping exiting the second stage airend. The control will log this message if it fails to receive a valid signal from this sensor.
STG 2 INPUT TEMP FAILURE
The stage two input RTD is the temperature probe in the stage two compressor airend intake. The control will log this message if it fails to receive a valid signal from this probe.
STG 1 DIS TRANSDUCER FAILURE
The stage one pressure transducer is the pressure sensor located in the piping exiting the first stage airend. The control will log this message if it fails to receive a valid signal from this sensor.
STG 1 DISCHARGE RTD FAILURE
The stage one discharge RTD is the temperature probe in the discharge tubing of the first stage airend. The control will log this message if it fails to receive a valid signal from this probe.
FLUID TRANSDUCER FAILURE
The fluid transducer is the pressure sensor located in fluid line feeding the airend bearings. The control will log this message if it fails to receive a valid signal from this sensor.
PKG TRANSDUCER FAILURE
The line transducer is the pressure sensor located downstream of the aftercooler. The control will log this message if it fails to receive a valid signal from this sensor.
AIR FILTER CLOGGED
There is a vacuum switch downstream of the air filter element that is used to determine the differential pressure across the filter element. A high differential pressure indicates a dirty filter element. If this condition is detected, the control will log the event. This will not shut down the compressor, but it can be useful in troubleshooting.
68 | Quincy Compressor® - QSD™ |
|
|