Section VIII - Power$ync IIOperation

Power$ync IIuses military time (i.e., 8:00AM is 08:00 and 2:00PM is 14:00).

TIME MENU

 

TO VIEW CURRENT TIME

PRESS F1

TO SET TIME AND DATE

PRESS F2

PRESS ENTER TO RETURN

To view the current time and date without changing them, press F1.

TIME AND DATE MENU

 

CURRENT TIME ON THIS CONTROL

00:00

CURRENT DATE ON THIS CONTROL

00/00/00

PRESS ENTER TO RETURN

 

 

 

Press ENTER to return the display to the Time Menu.

To reset the time and date, press F2 at the Time Menu. Because changing the time or date can disrupt schedule information, the control will display the following warning:

NOTICE

YOU ARE ABOUT TO RESET THE CLOCK

TO CHANGE THE TIME AND DATE PRESS F3

TO ABORT PRESS ENTER

Press F3 to move the display to the Set Time Menu.

SET TIME MENU

CURRENT TIME 00:00

PRESS ENTER TO ACCEPT VALUE

When this menu is displayed, the hours number will be flashing. Use the UP or DOWN arrow key to change the hour setting. When the hour setting is correct, press ENTER, the minute setting will now be flashing. Follow the above procedure to change the minute setting and press ENTER to accept the change. The control will briefly display a message that it is transferring the new time setting to all on-line compressors. There is no need to reset each compressor in a network. The control will automatically synchronize the network clocks.

The control will now move to the Set Date Menu.

SET DATE MENU

CURRENT DATE 00/00/00

PRESS ENTER TO ACCEPT VALUE

Follow the same procedure used to change the time. When the correct date has been entered or confirmed, the display will ask for the day of the week.

SET DAY MENU

CURRENT DAY MONDAY

PRESS ENTER TO ACCEPT VALUE

The current setting for the day of the week will be flashing. If it is incorrect, use the UP or DOWN arrow key until the correct day of the week is shown. Then press ENTER to accept. The display will indicate that the control is transferring the updated date and day information to the other compressors on the network.

From Compressor Maintenance Menu 1, press the UP arrow key to move the display to Compressor Maintenance Menu 2. This menu allows the operator to test the lift valve system or to check various control settings.

COMPRESSOR MAINTENANCE MENU 2

COMPRESSOR CONTROL TEST

PRESS F1

COMPRESSOR INFORMATION

PRESS F2

UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU

To test the operation of the Power$ync II® valves, press F1. To move to another maintenance menu, use the UP or DOWN arrow keys.

Quincy Compressor® - QSD™

53

 

 

Image 55
Contents QSD Series Page Table of Contents Section V Maintenance or Service Preparation Standard Warranty Dimensional Data air-cooled Dimensional Data water-cooled Section I General Safety PrecautionsSpare Parts Ordering Information Safety Alert SymbolsSection II Description Compression Cycle and Air Flow General DescriptionWater-cooled Cooling SystemLubricating Fluid System Moisture SeparatorCapacity Control System Electrical System Shutdown Conditions Back-up ControlHigh Discharge Air Temperature Lights IndicatorsSafety Sensors Main Power on LightSection II Description Location Section III InstallationMoving the Unit to the Installation Site ReceivingPiping Connections Piping Fit-up Manual Shutoff ValveGuards ElectricalWater Quality Water FlowFan Rotation Fluid LevelStopping the Compressor Normal Operation Section IV Operating ProceduresPrior to Starting Starting the CompressorPressure Readings Temperature Readings Water-cooledStopping the Compressor Emergency Section V Preparing for Maintenance or Service This page Intentionally Left Blank Fluid Specifications SafetySection VI Servicing Fluid Life Air FilterInput Shaft Seal Preparation for New Seal InstallationAirend Sealing System Seal InstallationAdjusting Pressure Switch Section VII Service AdjustmentsPressure Switch Pressure Switch Back-up Operating ModeThis page Intentionally Left Blank Do not switch modes with power on the compressor Section Viii Power$ync II OperationIntroduction to Power$ync Back-up Mode OperationContinuous Run Multiple Machine Operational ModeAuto Dual Time Delay Single Machine Operational ModesNetwork Load Delay Time Pressure SettingsConnecting Cable to the Power$ync II Circuit Board Network InstallationRocker Switch Settings Network Setup Network Voltage Tests on Power$ync II SystemsUP/DOWN DEADBAND, F1 EDIT, Enter Return Start-up Power-up DisplaysSection Viii Power$ync II Operation U19 Memory Failure Contact Your Service Representative Compressor in Back-up ModeU19 Data Checksum Error Press F2 to Update Deadband Data Error Press F1 to ClearU19 Data not Initialized Press F2 to Initialize Filter Needs Servicing Please Replace AS Soon AS Possible Compressor is Starting Start-up DisplaysOperational Displays Additional SensorsCompressor is Unloaded Compressor is Unloaded Minutes Left to ShutdownProgrammed Shutdown Press F2 Compressor Settings and Maintenance DisplaysMode and Pressure Displays Compressor Mode of Operation Auto Dual Timed Stop Press F1Press F1 to change the load and unload pressures Read Pressure Settings pages 34-35 beforePlease Wait Network Configuration in Progress Machine ID SetupMachine ID for this Compressor Press Enter to Accept Value UP/DOWN Machine ID, Enter Return Before setting or changing a sequence, readSequence Network Data UP/DOWN POSITION, F1 EDIT, Enter ReturnDAY Monday SEQ Abcd Network Configuration MenuDAY Monday SEQ To clear a particular sequence from the memory, press F1 Intake Filter Hours Filter Service HourmetersReset Service Hourmeters Compressor Hourmeter Menu Compressor HourmetersFluid Hours Reset to Press Enter to Return Press F1 to Reset Fluid Filter Hours Press Enter to ReturnFluid Filter Hours Reset to Press Enter to Return Press F1 to Reset Fluid Hours Press Enter to ReturnTime and Date Menu Current Time on this Control Compressor Maintenance Menu Compressor Control TestTime Menu To View Current Time To SET Time and DateFluid Press HorsepowerCompressor Control Test Menu Unload Valve Test Press F1 Unload PressNetwork Diagnostic Unit Configuration DateModem Baud Rate Setup Compressor Diagnostic Menu View Shutdown LOGSection Viii Power$ync II Operation ETOL00 FTOL00 Network Connection Data Confidence Modem INITIALIZATION** Init Indicator is lit, the indicator will remain litF1 to EDIT/ENTER to Accept Value Compressor has Shut Down Emergency Stop Button WAS Pressed Sequence Data Error Press F1 to Clear Schedule Data Error Compressor has Shut Down Take Corrective Action Back-up Mode until all faults have been corrected Inlet Temp Fluid Pressure STG 1 OUT Temp STG 2 in Temp Emergency Stop Pressed Shutdown Log MessagesMotor Overload STG 2 Discharge RTD Failure Control log has no entries at that point Probable Causes Corrective Action Failure to Start Section IX TroubleshootingUnscheduled Shutdown Section IX TroubleshootingProbable Causes Corrective Action Unscheduled Shutdown Frequent Fluid Filter Clogging Frequent Air Cleaner CloggingHigh Discharge Air Temperature Probable Causes Corrective Action Low Air DeliveryCompressor does not Unload when there is no Air Demand Too Rapid Cycling Between Load and Unload Excessive Fluid in Gearbox Vent Bowl Pressure Relief Valve ExhaustingExcessive Fluid in Buffing Air Vent Bowls Water in Buffing Air Vent BowlsHigh Interstage Pressure Low Delivery PressureMicroprocessor Will Not Display Messages Erroneous DisplaysInterval Action Section X- Maintenance ScheduleDaily Operating Record Quincy Compressor QSD Quincy Compressor QSD