Section VIII - Power$ync IIOperation

controller will turn the machine off. If SHUTDOWN is pressed accidentally and the unit is in the process of shutting down but has not yet stopped, the programmed shutdown can be aborted by pressing SHUTDOWN again.

Compressor Settings and Maintenance Displays

The initial Start-up Display (page 43) offers the user the choice to press START (to begin compressor operation) or ENTER (to move to the compressor setup and maintenance menu). Once compressor operation begins, the operator will see one of the Operational Displays (pages 43-44). If ENTER is pressed, the operator will be directed into a variety of setup and maintenance displays which allow changes to operating pressures, mode of operation, date and time, or to check and/or reset maintenance hourmeters. These setup and maintenance options can be accessed at any time during normal compressor operation by pressing ENTER when the controller has an Operational Display showing.

The Setup Menu portion of the Power$ync IIcontrol displays can be divided into several groups; Pressure Settings, Mode of Operation, Maintenance Hourmeters, Modem Communications, Clock and Control Testing.

IMPORTANT

a)If a situation occurs requiring a WARNING message to be displayed, that message will interrupt any active display.

b)ENTER will always accept the displayed data and either move forward to the next display or backward to the previous display, depending on the requirements of the display.

c)If the display does not make reference to ENTER, pressing ENTER will take the operator back to the previous display.

From the initial Start-up Display or any of the Operational Displays, pressing ENTER will call the first Setup Menu.

Mode and Pressure Displays

COMPRESSOR SETUP MENU

MODE AND PRESSURE MENU PRESS F1

MAINTENANCE MENU PRESS F2

PRESS ENTER TO RETURN

Press F1 to access the Mode and Pressure Menu to select Auto Dual, Continuous Run or Network Mode. Press F2 to move into the Maintenance Menu where hourmeters can be checked and set, time and date can be changed and Power$ync IIvalve operation can be checked. Press ENTER to return to the previous display.

F1allows the mode of operation to be selected or changed. For an explanation of the modes of operation refer to pages 32-33.

COMPRESSOR MODE OF OPERATION

AUTO DUAL TIMED STOP

PRESS F1

CONTINUOUS RUN

PRESS F2

NETWORK SCHEDULED ROTATION PRESS F3

Press F1 to access the Auto Dual Configuration Menu. Press F2 to access theContinuous Run Configuration Menu. F3 accesses the Network Configuration Menu. Although it is not displayed in this menu, ENTER can be pressed to return to the previous Setup Menu. Pressing any F key will result in the compressor switching modes of operation as soon as ENTER is pressed.

AUTO DUAL CONFIGURATION

SET LOAD/UNLOAD PRESSURES PRESS F1

SET SHUTDOWN TIMER PRESS F2

The Auto Dual Configuration Menu allows the operator to set various operating parameters for a compressor running in this mode. The compressor comes from the factory with preset parameters based on the information provided on the order. These should only be changed if system conditions are different from those present at the time the order was placed.

Quincy Compressor® - QSD™

45

 

 

Image 47
Contents QSD Series Page Table of Contents Section V Maintenance or Service Preparation Standard Warranty Dimensional Data air-cooled Dimensional Data water-cooled Section I General Safety PrecautionsSpare Parts Ordering Information Safety Alert SymbolsSection II Description Compression Cycle and Air Flow General DescriptionWater-cooled Cooling SystemLubricating Fluid System Moisture SeparatorCapacity Control System Electrical System Shutdown Conditions Back-up ControlHigh Discharge Air Temperature Lights IndicatorsSafety Sensors Main Power on LightSection II Description Location Section III InstallationMoving the Unit to the Installation Site ReceivingPiping Connections Piping Fit-up Manual Shutoff ValveGuards ElectricalWater Quality Water FlowFan Rotation Fluid LevelStopping the Compressor Normal Operation Section IV Operating ProceduresPrior to Starting Starting the CompressorStopping the Compressor Emergency Temperature Readings Water-cooledPressure Readings Section V Preparing for Maintenance or Service This page Intentionally Left Blank Section VI Servicing SafetyFluid Specifications Fluid Life Air FilterInput Shaft Seal Preparation for New Seal InstallationAirend Sealing System Seal InstallationAdjusting Pressure Switch Section VII Service AdjustmentsPressure Switch Pressure Switch Back-up Operating ModeThis page Intentionally Left Blank Do not switch modes with power on the compressor Section Viii Power$ync II OperationIntroduction to Power$ync Back-up Mode OperationContinuous Run Multiple Machine Operational ModeAuto Dual Time Delay Single Machine Operational ModesNetwork Load Delay Time Pressure SettingsConnecting Cable to the Power$ync II Circuit Board Network InstallationRocker Switch Settings UP/DOWN DEADBAND, F1 EDIT, Enter Return Network Voltage Tests on Power$ync II SystemsNetwork Setup Start-up Power-up DisplaysSection Viii Power$ync II Operation U19 Memory Failure Contact Your Service Representative Compressor in Back-up ModeU19 Data not Initialized Press F2 to Initialize Deadband Data Error Press F1 to ClearU19 Data Checksum Error Press F2 to Update Filter Needs Servicing Please Replace AS Soon AS Possible Compressor is Starting Start-up DisplaysOperational Displays Additional SensorsProgrammed Shutdown Compressor is Unloaded Minutes Left to ShutdownCompressor is Unloaded Press F2 Compressor Settings and Maintenance DisplaysMode and Pressure Displays Compressor Mode of Operation Auto Dual Timed Stop Press F1Press F1 to change the load and unload pressures Read Pressure Settings pages 34-35 beforeMachine ID for this Compressor Press Enter to Accept Value Machine ID SetupPlease Wait Network Configuration in Progress UP/DOWN Machine ID, Enter Return Before setting or changing a sequence, readSequence Network Data UP/DOWN POSITION, F1 EDIT, Enter ReturnDAY Monday SEQ Network Configuration MenuDAY Monday SEQ Abcd To clear a particular sequence from the memory, press F1 Intake Filter Hours Filter Service HourmetersReset Service Hourmeters Compressor Hourmeter Menu Compressor HourmetersFluid Hours Reset to Press Enter to Return Press F1 to Reset Fluid Filter Hours Press Enter to ReturnFluid Filter Hours Reset to Press Enter to Return Press F1 to Reset Fluid Hours Press Enter to ReturnTime and Date Menu Current Time on this Control Compressor Maintenance Menu Compressor Control TestTime Menu To View Current Time To SET Time and DateFluid Press HorsepowerCompressor Control Test Menu Unload Valve Test Press F1 Unload PressNetwork Diagnostic Unit Configuration DateModem Baud Rate Setup Compressor Diagnostic Menu View Shutdown LOGSection Viii Power$ync II Operation ETOL00 FTOL00 Network Connection Data Confidence F1 to EDIT/ENTER to Accept Value Indicator is lit, the indicator will remain litModem INITIALIZATION** Init Compressor has Shut Down Emergency Stop Button WAS Pressed Sequence Data Error Press F1 to Clear Schedule Data Error Compressor has Shut Down Take Corrective Action Back-up Mode until all faults have been corrected Inlet Temp Fluid Pressure STG 1 OUT Temp STG 2 in Temp Emergency Stop Pressed Shutdown Log MessagesMotor Overload STG 2 Discharge RTD Failure Control log has no entries at that point Probable Causes Corrective Action Failure to Start Section IX TroubleshootingUnscheduled Shutdown Section IX TroubleshootingProbable Causes Corrective Action Unscheduled Shutdown Frequent Fluid Filter Clogging Frequent Air Cleaner CloggingHigh Discharge Air Temperature Probable Causes Corrective Action Low Air DeliveryCompressor does not Unload when there is no Air Demand Too Rapid Cycling Between Load and Unload Excessive Fluid in Gearbox Vent Bowl Pressure Relief Valve ExhaustingExcessive Fluid in Buffing Air Vent Bowls Water in Buffing Air Vent BowlsHigh Interstage Pressure Low Delivery PressureMicroprocessor Will Not Display Messages Erroneous DisplaysInterval Action Section X- Maintenance ScheduleDaily Operating Record Quincy Compressor QSD Quincy Compressor QSD