Section III - Installation
Clean air is essential for your Quincy compressor. Always select a source providing the cleanest air possible. When an outside air source is used, keep all piping as short and direct as possible.
Table 3-1 – Water Flow
MODEL | 50 | 75 | 100 | |
|
|
|
| |
GPM @ 50°F | 10 | 13 | 16 | |
|
|
|
| |
GPM @ 70°F | 12 | 16 | 20 | |
|
|
|
| |
GPM @ 90°F | 15 | 20 | 24 | |
|
|
|
| |
WATER PRESS | 40/100 | 40/100 | 40/100 | |
(MAX/MIN) | ||||
|
|
| ||
|
|
|
|
Minimum water quality is listed in Table
Contact the factory if you plan to use a water/glycol coolant, salt or brackish water.
Table 3-2 – Water Quality
| ONCE | COOLING | |
ITEM | THROUGH | TOWER | |
WATER | WATER | ||
| |||
| SYSTEM | SYSTEM | |
|
|
| |
PH AT 77°F (25°C) | 6.5 – 8.0 | 6.5 – 8.0 | |
|
|
| |
CONDUCTIVITY AT 77°F | <500 | <200 | |
(25°C) (UV/CM) | |||
|
| ||
|
|
| |
TOTAL HARDNESS AS | <200 | <50 | |
CACO3 (PPM) | |||
|
| ||
|
|
| |
<100 | <50 | ||
(PPM) | |||
|
| ||
|
|
| |
CHLORINE LON;CL (PPM) | <200 | <50 | |
|
|
| |
SULFURIC ACID IRON; SO4 | <200 | <50 | |
(PPM) | |||
|
| ||
|
|
| |
TOTAL IRON; FE (PPM) | <1.0 | <0.3 | |
|
|
| |
SILICA, SIO2 (PPM) | <50 | <30 | |
|
|
| |
SULFUR ION; S 2 (PPM) | 0 | 0 | |
|
|
| |
AMMONIUM ION; NH4+ | 0 | 0 | |
(PPM) | |||
|
| ||
|
|
|
20 | Quincy Compressor® - QSD™ |
|
|