Section VIII - Power$ync II™ Operation
During the initial
FLUID PRESSURE__________
COMPRESSOR HAS SHUT DOWN **NOTICE** U19 MEMORY FAILURE REFER TO YOUR SERVICE MANUAL
This condition will prevent the compressor from operating. Attempt to correct the situation by turning power off to the compressor and then reapplying power. This will begin the diagnostic program again. It may be possible to run the compressor on the default setup values, if the original setup data is not usable. Call your service representative if this does not correct the problem. Your service representative can determine whether correct setup information can be reentered into the controller or the memory board needs to be replaced. The compressor can be operated in
In the Network Mode, the controller continually checks for other errors. These include:
NOTICE
SEQUENCE DATA ERROR
PRESS F1 TO CLEAR
NOTICE
SCHEDULE DATA ERROR
PRESS F1 TO CLEAR
These two messages may appear if the
NOTICE
THIS COMPRESSOR MACHINE ID
IS ALREADY IN USE
PRESS ENTER TO CONTINUE
If the main memory board of the controller has to be replaced for some reason and the machine is on a network, the new board may have a default machine ID that conflicts with another machine on the network. Press ENTER to clear this screen and then reassign a new machine ID to this unit. See Compressor Settings and Maintenance Displays for instructions on this procedure.
60 | Quincy Compressor® - QSD™ |
|
|