| Section IX - Troubleshooting |
|
|
|
|
Probable Causes: | Corrective Action: |
| |
| |
Compressor does not revert to Load when Service Line Pressure Drops to Reset Pressure: | |
|
|
LOOSE WIRING CONNECTION | CHECK AND TIGHTEN WIRING TERMINALS. |
FAULTY PRESSURE SENSOR | REPAIR OR REPLACE AS NECESSARY. |
FAULTY SOLENOID | REPAIR OR REPLACE AS NECESSARY. |
FAULTY TIMER | CHECK AND REPLACE TIMER. |
FAULTY LIFT VALVE(S) | REPAIR OR REPLACE AS NECESSARY. |
FAULTY BLOWDOWN VALVE(S) | NO AIR SHOULD BE BLOWING OUT FROM THE MUFFLERS DURING |
| LOADED OPERATION. |
NETWORK OUT OF SEQUENCE OR | CHECK AND RESET SEQUENCE OR SCHEDULE AS NECESSARY. |
SCHEDULE |
|
Compressor Will not Time out or Shut down when Unloaded (Auto Dual Only):
LEAKS IN CONTROL LINES
LEAKS IN SERVICE LINES
STORAGE CAPACITY TOO SMALL
LEAKS IN MINIMUM PRESSURE CHECK VALVE
FAULTY AIR PRESSURE SWITCH
FAULTY AIR PRESSURE SENSORS
CHECK AND REPAIR ANY LEAKS.
CHECK PLANT AIR DISTRIBUTION SYSTEM FOR LEAKS.
ADD MORE STORAGE CAPACITY AS CLOSE TO THE COMPRESSOR AS POSSIBLE.
REPAIR OR REPLACE AS NECESSARY.
REPAIR OR REPLACE AS NECESSARY.
REPLACE AS NECESSARY.
Too Rapid Cycling Between Load and Unload:
LEAKS IN CONTROL LINES | CHECK AND REPAIR ANY LEAKS. |
WATER OR ICE IN CONTROL LINES | DRAIN LINES, REPLACE AS NECESSARY. |
FAULTY AIR PRESSURE SENSORS | REPLACE AS NECESSARY. |
STORAGE CAPACITY TOO SMALL | ADD STORAGE CAPACITY (MINIMUM OF THREE GALLONS PER |
| CFM). |