Quinny 65040-AB manual Section I General, Safety Precautions

Page 8

Section I - General

Safety Precautions

Safety Alert Symbols

Serial/Model Identification Plate

Spare Parts Ordering Information

Safety Precautions

Read this manual and follow all instructions prior to installing or operating this compressor.

Listed below are some, but not all, safety precautions that must be observed with compressors and compressed air systems.

Failure to follow any of these warnings may result in severe personal injury, death, property damage and/ or compressor damage.

Air from this compressor will cause severe injury or death if used for breathing or food processing. Air used for these processes must meet OSHA 29 CFR 1910.134 regulations.

Disconnect and lockout all power supplies to the compressor plus any remote controllers prior to servicing the unit.

Never assume it is safe to work on the compressor because it is not operating. Many installations have automatic start/stop controls and the compressor may start at any time.

This compressor is designed for use in the compression of normal atmospheric air only. No other gases, vapors or fumes should be exposed to the compressor intake, nor processed through the compressor.

Relieve all pressure internal to the compressor prior to servicing. Do not depend on check valves to hold system pressure.

A properly sized pressure relief valve must be installed in the discharge piping ahead (upstream) of any shut-off valve (block valve), heat exchanger, orifice or any potential blockage point. Failure to install a pressure relief valve could result in the rupturing or explosion of some compressor component.

Do not change the pressure setting of the pressure relief valve, restrict the function of the pressure relief valve, or replace the pressure relief valve with a plug. Over pressurization of system or compressor components can occur, resulting in death, severe personal injury or property damage.

Never use plastic pipe, rubber hose, or soldered joints in any part of the compressed air system. Failure to ensure system compatibility with compressor piping is dangerous.

Never use a flammable or toxic solvent for cleaning the air filter or any parts.

Do not remove any guards or cabinet panels or attempt to service any compressor part while the compressor is operating.

Do not operate the compressor at pressures in excess of its rating.

Observe control panel displays daily to ensure compressor is operating properly.

Follow all maintenance procedures and check all safety devices on schedule.

Never disconnect or tamper with the high air temperature (HAT) sensors.

Compressed air is dangerous, do not play with it.

Use the correct fluid at all times.

Do not rely on the discharge air line check valve.

Do not override any safety or shutdown devices.

Keep doors closed during operation. The noise level inside cabinet exceeds 100 decibels (dBA) and the operating temperature of some components is sufficient to burn the skin.

NOTICE

These instructions, precautions and descriptions cover standard Quincy manufactured QSDSeries air compressors.

As a service to our customers, we often modify or construct packages to the customers specifications. This manual may not be appropriate in those cases.

NOTE

Every effort has been taken to ensure complete and correct instructions have been included in this manual, however, possible product updates and changes may have occurred since this printing. Quincy Compressor reserves the right to change specifications without incurring any obligation for equipment previously or subsequently sold. Not responsible for typographical errors.

6

Quincy Compressor® - QSD™

 

 

Image 8
Contents QSD Series Page Table of Contents Section V Maintenance or Service Preparation Standard Warranty Dimensional Data air-cooled Dimensional Data water-cooled Safety Precautions Section I GeneralSafety Alert Symbols Spare Parts Ordering InformationSection II Description General Description Compression Cycle and Air FlowCooling System Lubricating Fluid SystemMoisture Separator Water-cooledCapacity Control System Electrical System Back-up Control Shutdown ConditionsIndicators Safety SensorsMain Power on Light High Discharge Air Temperature LightsSection II Description Section III Installation Moving the Unit to the Installation SiteReceiving LocationPiping Connections Manual Shutoff Valve Piping Fit-upElectrical GuardsWater Flow Water QualityFluid Level Fan RotationSection IV Operating Procedures Prior to StartingStarting the Compressor Stopping the Compressor Normal OperationStopping the Compressor Emergency Temperature Readings Water-cooledPressure Readings Section V Preparing for Maintenance or Service This page Intentionally Left Blank Section VI Servicing SafetyFluid Specifications Air Filter Fluid LifePreparation for New Seal Installation Input Shaft SealSeal Installation Airend Sealing SystemSection VII Service Adjustments Pressure SwitchPressure Switch Back-up Operating Mode Adjusting Pressure SwitchThis page Intentionally Left Blank Section Viii Power$ync II Operation Introduction to Power$yncBack-up Mode Operation Do not switch modes with power on the compressorMultiple Machine Operational Mode Auto Dual Time DelaySingle Machine Operational Modes Continuous RunPressure Settings Network Load Delay TimeNetwork Installation Connecting Cable to the Power$ync II Circuit BoardRocker Switch Settings UP/DOWN DEADBAND, F1 EDIT, Enter Return Network Voltage Tests on Power$ync II SystemsNetwork Setup Power-up Displays Start-upSection Viii Power$ync II Operation Compressor in Back-up Mode U19 Memory Failure Contact Your Service RepresentativeU19 Data not Initialized Press F2 to Initialize Deadband Data Error Press F1 to ClearU19 Data Checksum Error Press F2 to Update Filter Needs Servicing Please Replace AS Soon AS Possible Start-up Displays Operational DisplaysAdditional Sensors Compressor is StartingProgrammed Shutdown Compressor is Unloaded Minutes Left to ShutdownCompressor is Unloaded Compressor Settings and Maintenance Displays Mode and Pressure DisplaysCompressor Mode of Operation Auto Dual Timed Stop Press F1 Press F2Read Pressure Settings pages 34-35 before Press F1 to change the load and unload pressuresMachine ID for this Compressor Press Enter to Accept Value Machine ID SetupPlease Wait Network Configuration in Progress Before setting or changing a sequence, read Sequence Network DataUP/DOWN POSITION, F1 EDIT, Enter Return UP/DOWN Machine ID, Enter ReturnDAY Monday SEQ Network Configuration MenuDAY Monday SEQ Abcd To clear a particular sequence from the memory, press F1 Filter Service Hourmeters Reset Service HourmetersCompressor Hourmeter Menu Compressor Hourmeters Intake Filter HoursPress F1 to Reset Fluid Filter Hours Press Enter to Return Fluid Filter Hours Reset to Press Enter to ReturnPress F1 to Reset Fluid Hours Press Enter to Return Fluid Hours Reset to Press Enter to ReturnCompressor Maintenance Menu Compressor Control Test Time Menu To View Current TimeTo SET Time and Date Time and Date Menu Current Time on this ControlHorsepower Compressor Control Test Menu Unload Valve Test Press F1Unload Press Fluid PressUnit Configuration Date Modem Baud Rate SetupCompressor Diagnostic Menu View Shutdown LOG Network DiagnosticSection Viii Power$ync II Operation ETOL00 FTOL00 Network Connection Data Confidence F1 to EDIT/ENTER to Accept Value Indicator is lit, the indicator will remain litModem INITIALIZATION** Init Compressor has Shut Down Emergency Stop Button WAS Pressed Sequence Data Error Press F1 to Clear Schedule Data Error Compressor has Shut Down Take Corrective Action Back-up Mode until all faults have been corrected Inlet Temp Fluid Pressure STG 1 OUT Temp STG 2 in Temp Shutdown Log Messages Emergency Stop PressedMotor Overload STG 2 Discharge RTD Failure Control log has no entries at that point Section IX Troubleshooting Probable Causes Corrective Action Failure to StartSection IX Troubleshooting Unscheduled ShutdownProbable Causes Corrective Action Unscheduled Shutdown Frequent Air Cleaner Clogging High Discharge Air TemperatureProbable Causes Corrective Action Low Air Delivery Frequent Fluid Filter CloggingCompressor does not Unload when there is no Air Demand Too Rapid Cycling Between Load and Unload Pressure Relief Valve Exhausting Excessive Fluid in Buffing Air Vent BowlsWater in Buffing Air Vent Bowls Excessive Fluid in Gearbox Vent BowlLow Delivery Pressure High Interstage PressureErroneous Displays Microprocessor Will Not Display MessagesSection X- Maintenance Schedule Interval ActionDaily Operating Record Quincy Compressor QSD Quincy Compressor QSD