Lead Screw: The lead screw should be lubri- cated with multi-purpose grease once a month. See Figure 50 and Parts Beakdown, P0633411, Page 61 for location. Remove the left side access panel for ingress.
Lead
Screw
Planer
Column
Figure 50. Planer column and lead screw.
Planer Column: Clean with solvent, wipe dry, and relubricate with multi-purpose grease when needed.
Worm Gear: Inspect every six months and lubri- cate with multi-purpose grease when needed (see Parts Breakdown, P0633409). Remove the worm gear box (see P0633407, Page 61) to inspect.
-36-
Fence: Lubricate with multi-purpose grease when needed in the locations shown in Figure 51.