Installation

4

 

 

Major Components

And What They Do

Impeller and Jet

Impeller turns with motor shaft, causing water to fly out from its rim by centrifugal force. Impeller rotation creates a vacuum which pulls in more water. Part of the water is diverted back to the jet where it passes through the nozzle and venturi. This creates more vacuum to draw in more water.

In shallow wells (less than 25 feet deep), the vacuum created at the pump is enough to pull water to the pump. Therefore,­ for shallow well use the jet is built into the pump.

Pre-Charged Tank

The tank serves two functions. It provides a reservoir of water under pressure and maintains a cushion of air pressure to prevent pipe hammering and possible damage to plumbing components. When water is drawn off through the house fixtures, the pressure in the tank is lowered and the pump starts.

Pressure Switch

The pressure switch provides for automatic operation. Pump starts when pressure drops to 30 pounds and stops when pressure reaches 50 pounds.

Check Valve or Foot Valve

Install a check valve as close to well as possible on well point installations. A foot valve must be installed in the well on dug or cased wells. See Figures 1 and 2. For long horizontal pipe runs, install check valve as close to well as possible (all types of wells).

Horizontal Piping from Well to Pump

When the pump is offset more than 25 feet from the well, horizontal suction pipe size should be increased to reduce friction losses. Never install a suction pipe that is smaller than the suction tapping of the pump.

1-1/4”

1-1/2”

2”

 

 

 

Up to 25 Ft.

25 to 50 Ft.

50 to 200 Ft.

Discharge Pipe Sizes

When the pump is some distance from the house or point of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction.

1”

1-1/4”

1-1/2”

 

 

 

Up to 25 Ft.

25 to 100 Ft.

100 to 600 Ft.

Tank

Tank is pre-charged with 40 pounds per square inch (PSI) air pressure at the factory. Your tank requires an air charge of 28 PSI for proper operation; check tank pressure with tire gauge and adjust air charge as needed. Tank pre-charge should be checked annually; see Discharge Pipe and Tank Connections.

In areas where the temperature is high for long periods of time, the tank pre-charge pressure may increase. This may reduce the tank drawdown (amount of water available per cycle). If this occurs, reduce the pre-charge pressure until it is 2 PSI below the pump cut-in setting of the pressure switch (normally 30 PSI).

It is necessary to flush all air out of the piping system and water reservoir portion of the pre-charged tank. This is required on new installations, pumps requiring repriming and pumps that have been disassembled for service. Do this as follows:

1.Open faucets furthest from tank and allow pump to operate.

2.Air in the system will cause a sputtering flow; allow faucets to run until you have a steady, air free stream.

3.Open and close faucets repeatedly until you are sure all air has been removed.

4.If stream does not become steady, air may be leaking into the system; check for leaks in the piping on the suction side of the pump.

NOTICE: To prevent waterlogging, check tank air charge annually. See Discharge Pipe and Tank Connections.

Replacing An Old Pump

Hazardous voltage.. Disconnect power to pump before working on pump or motor.

1.Drain and remove the old pump. Check the old pipe for scale, lime, rust, etc., and replace it if necessary.

2.Install the pump in the system. Make sure that all pipe joints in the suction pipe are air-tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.

3.Adjust the pump mounting height so that the plumbing connections do not put a strain on the pump body. Support the pipe so that the pump body does not take the weight of piping or fittings.

You have just completed the well plumbing for your new shallow well jet pump. Please go to Discharge Pipe and Tank Connections.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 4
Contents Pages Call Composer le 1 800Pages Español Safety Important Safety InstructionsElectrical Safety General SafetyWarranty Exceptions to the Twelve 12 Month Limited WarrantySewage Pumps General Terms and Conditions Limitation of RemediesInstallation Major Components What They DoHorizontal Piping from Well to Pump Replacing An Old PumpWell Point Driven Point Installation Figure Cased Well Installation, 2 or Larger Casing FigureTank Pre-Charge Discharge Pipe and Pressure Tank ConnectionsTank Pumping Cycle Motor Switch Settings Wiring ConnectionsElectrical Dial Type Voltage SelectorWiring Chart Recommended Wire and Fuse Sizes Electrical Priming WinterizePreparing to Start the Pump PrimingTroubleshooting Symptom Possible Causes Corrective ActionRepair Part Part Description Part NumberDescription Qty Sécurité Directives de sécurité importantesSécurité concernant l’électricité Sécurité généraleGarantie Pompes d’eaux d’égoutExceptions à la garantie limitée de douze 12 mois Modalités générales et restriction des recoursPrincipaux composants et fonctions de ceux-ci Tuyauterie horizontale entre le puits et la pompeInstallation de la pointe filtrante Figure Pas àPrécharge du réservoir Branchements du tuyau de refoulementCycle de pompage du réservoir Électricité Sélecteur de tension à cadranConnexions des fils Réglages de l’interrupteur du moteurÉlectricité Amorçage Hivérisation Préparations avant le démarrage de la pompeAmorçage Hivérisation de la pompeDiagnostic des pannes Symptômes Causes probables RemèdesPièces de rechange Réf Désignation des pièces No.. des piècesPièces de rechange Réf Désignation QtéSeguridad Instrucciones importantes de seguridadSeguridad electrica Seguridad generalGarantía Bombas cloacalesExcepciones para la garantía limitada de doce 12 meses Términos y condiciones generales Limitación de recursosInstalación Componentes principales y sus funcionesTubería horizontal desde el pozo a la bomba Reemplazo de una bomba viejaInstalacion del punto del pozo punto de hincar EscalaPrecarga del tanque Ciclo de bombeo del tanqueConfiguraciones del interruptor del motor ElectricidadSelector de tensión de tipo cuadrante Conexiones de los cablesPreparación para arrancar la bomba Pozo profundo CebadoPreparación de la bomba para el invierno 14/14 2/2 12/14 3.3/2 10/14 5.5/2 10/12 5.5/3.3Localización de fallas Síntoma Causas probables Acción correctivaPiezas de repuesto Descripción de la pieza No.. de la piezaPiezas de repuesto Descripción de la pieza Cant