Simer Pumps 2806E owner manual Discharge Pipe and Pressure Tank Connections, Tank Pre-Charge

Page 6

Discharge Pipe and Pressure Tank Connections

6

 

 

Tank Pumping Cycle

 

 

 

Water

Water

Water

 

 

 

 

 

 

1

2

3

4

5

1.

Tank nearly empty – air expands filling area above

4.

Water being drawn from tank – compressed tank air

 

vinyl water cell.

 

 

forces water out of water cell.

 

2.

Water begins to enter tank – air is compressed above

5.

Water cell completely empty – new cycle ready

 

water cell as it fills with water.

 

to begin.

 

3.Pump-up cycle completed – air now compressed to cut off setting of pressure switch.

Figure 3

Tank Pre-Charge

NOTICE: Be sure that power to the pump is OFF when checking the tank’s precharge.

Check the pre-charge of air in the tank with an ordinary tire gauge. The pre-charge should be 2 PSI less than the cut-in setting of the pump’s pressure switch. The pre- charge is measured when there is no water pressure in the tank. Your new pump has a 30/50 PSI switch, so adjust the tank pre-charge pressure to 28 PSI.

Congratulations! You have just completed the tank connection for your jet pump. Please go to Electrical for electrical hookup.

Sealing Pipe Joints

Use only PTFE pipe thread sealant tape or PTFE- based joint compounds for making all threaded connections to the pump itself. Do not use pipe joint compounds on plastic pumps: they can react with the plastic in pump components. Make sure that all pipe joints in the suction pipe are air tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 6
Contents Call Composer le 1 800 PagesPages Español Electrical Safety SafetyImportant Safety Instructions General SafetySewage Pumps WarrantyExceptions to the Twelve 12 Month Limited Warranty General Terms and Conditions Limitation of RemediesHorizontal Piping from Well to Pump InstallationMajor Components What They Do Replacing An Old PumpWell Point Driven Point Installation Figure Cased Well Installation, 2 or Larger Casing FigureDischarge Pipe and Pressure Tank Connections Tank Pre-ChargeTank Pumping Cycle Electrical Motor Switch SettingsWiring Connections Dial Type Voltage SelectorPreparing to Start the Pump Wiring Chart Recommended Wire and Fuse SizesElectrical Priming Winterize PrimingTroubleshooting Symptom Possible Causes Corrective ActionRepair Part Part Description Part NumberDescription Qty Sécurité concernant l’électricité SécuritéDirectives de sécurité importantes Sécurité généraleExceptions à la garantie limitée de douze 12 mois GarantiePompes d’eaux d’égout Modalités générales et restriction des recoursPrincipaux composants et fonctions de ceux-ci Tuyauterie horizontale entre le puits et la pompeInstallation de la pointe filtrante Figure Pas àBranchements du tuyau de refoulement Précharge du réservoirCycle de pompage du réservoir Connexions des fils ÉlectricitéSélecteur de tension à cadran Réglages de l’interrupteur du moteurAmorçage Électricité Amorçage HivérisationPréparations avant le démarrage de la pompe Hivérisation de la pompeDiagnostic des pannes Symptômes Causes probables RemèdesPièces de rechange Réf Désignation des pièces No.. des piècesPièces de rechange Réf Désignation QtéSeguridad electrica SeguridadInstrucciones importantes de seguridad Seguridad generalExcepciones para la garantía limitada de doce 12 meses GarantíaBombas cloacales Términos y condiciones generales Limitación de recursosTubería horizontal desde el pozo a la bomba InstalaciónComponentes principales y sus funciones Reemplazo de una bomba viejaInstalacion del punto del pozo punto de hincar EscalaPrecarga del tanque Ciclo de bombeo del tanqueSelector de tensión de tipo cuadrante Configuraciones del interruptor del motorElectricidad Conexiones de los cablesPreparación de la bomba para el invierno Preparación para arrancar la bomba Pozo profundoCebado 14/14 2/2 12/14 3.3/2 10/14 5.5/2 10/12 5.5/3.3Localización de fallas Síntoma Causas probables Acción correctivaPiezas de repuesto Descripción de la pieza No.. de la piezaPiezas de repuesto Descripción de la pieza Cant