Automatic Charging Mode
When an Automatic Charge is performed, the charger switches to the Maintain Mode (see below) automatically after the battery is charged.
Aborted Charge
If charging can not be completed normally, charging will abort. When charging aborts, the charger’s output is shut off, and the CHARGING (yellow) LED will blink. To reset after an aborted charge, either disconnect the battery or turn off the charger.
Desulfation Mode
If the battery is left discharged for an extended period of time, it could become sulfated and not accept a normal charge. If the charger detects a sulfated battery, the charger will switch to a special mode of operation designed for such batteries. If successful, normal charging will resume after the battery is desulfated. Desulfation could take 8 to 10 hours. If desulfation fails, charging will abort and the CHARGING (yellow) LED will blink.
Completion of Charge
Charge completion is indicated by the CHARGED (green) LED. When lit, the charger has switched to the Maintain Mode of operation.
Maintain Mode (Float-Mode Monitoring)
When the CHARGED (green) LED is lit, the charger has started Maintain Mode. In this mode, the charger keeps the battery fully charged by delivering a small current when necessary. If the battery voltage drops below a preset level, the charger will go back into Charge Mode until the battery voltage returns to the full charge level, at which point the charger will return to Maintain Mode.
NOTE: The charger automatically switches between Charge Mode and Maintain Mode as necessary. The CHARGED (green) LED will cycle on when the battery is at full charge and off when the voltage drops below a preset level and the charger goes into Charge Mode. This cycle will continue, and the CHARGED (green) LED will stay on for longer periods of time as the battery becomes more fully charged.
Power Saving Mode
The charger has an internal relay that switches the power transformer on and off automatically. This means, that the charger uses very little power when in standby mode or maintain mode.
General Charging Notes
Fan: The charger is designed to control its cooling fan for efficient operation. Consequentially, it is normal for the fan to start and stop when maintaining a fully charged battery. Keep the area near the charger clear of obstructions to allow the fan to operate efficiently.
• 7 •